Abstract:
Objective: To compare radiation doses among pediatric age groups undergoing chest computed tomography (CT), identify the major factors influencing radiation dose, and develop a radiation dose prediction model incorporating age and individual characteristics to provide an evidence-based reference for optimizing age-adaptive clinical low-dose scanning protocols. Methods: This retrospective study included 512 children aged 0–14 years who underwent non-contrast chest CT at Handan Central Hospital between January 2025 and June 2026. Patients were stratified into four age groups: infants (0–1 year, n = 86), toddlers (1–3 years, n = 124), preschool-aged children (3–6 years, n = 138), and school-aged children (6–14 years, n = 164). Automatic tube current modulation was used for all examinations. The volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded. The size-specific dose estimate (SSDE) was calculated according to American Association of Physicists in Medicine (AAPM) Report No. 204, and the effective dose (ED) was estimated using pediatric chest conversion factors. Pearson or Spearman correlation analysis was performed to assess the associations of radiation dose with age, body weight, body mass index, and scan length. Multiple linear regression analysis was used to identify independent factors associated with radiation dose and develop a dose prediction model. Results: CTDIvol, DLP, SSDE, and ED increased with age across the four groups, with statistically significant differences between groups (
P < 0.05). Compared with the infant group, the school-aged group had significantly higher CTDIvol (3.82 ± 1.15 mGy), DLP (98.46 ± 32.17 mGy·cm), and ED (1.52 ± 0.50 mSv) (
P < 0.01). Pearson correlation analysis showed that body weight was strongly and positively correlated with CTDIvol (
r = 0.724), DLP (
r = 0.812), and SSDE (
r = 0.685) (all
P < 0.01). Scan length was also strongly and positively correlated with DLP (
r = 0.856). Multiple linear regression analysis identified body weight, scan length, and tube voltage as independent predictors of CTDIvol (R
2 = 0.883,
P < 0.001). The resulting prediction model was: Predicted CTDIvol = 0.42 + 0.068 × body weight (kg) + 0.015 × scan length (cm) + 0.012 × tube voltage (kV). Conclusion: Radiation doses from pediatric chest CT examinations differ significantly across age groups. Body weight and scan length are major factors associated with radiation dose. The prediction model incorporating body weight, scan length, and tube voltage demonstrated good model fit and may provide quantitative support for individualized low-dose scanning protocols and pre-scan radiation dose estimation in clinical practice.