ISSN 1004-4140
CN 11-3017/P

中小体质指数患者腹部能谱CT血管成像双低扫描方案优化

浦仁旺, 李智勇, 刘义军, 刘静红, 葛莹, 刘爱连

浦仁旺, 李智勇, 刘义军, 刘静红, 葛莹, 刘爱连. 中小体质指数患者腹部能谱CT血管成像双低扫描方案优化[J]. CT理论与应用研究, 2015, 24(2): 153-159. DOI: 10.15953/j.1004-4140.2015.24.02.01
引用本文: 浦仁旺, 李智勇, 刘义军, 刘静红, 葛莹, 刘爱连. 中小体质指数患者腹部能谱CT血管成像双低扫描方案优化[J]. CT理论与应用研究, 2015, 24(2): 153-159. DOI: 10.15953/j.1004-4140.2015.24.02.01
PU Ren-wang, LI Zhi-yong, LIU Yi-jun, LIU Jing-hong, GE Ying, LIU Ai-lian. Optimizing Abdominal Spectral CT Angiography Imaging with Double Low Scan Protocol in Small BMI Patients[J]. CT Theory and Applications, 2015, 24(2): 153-159. DOI: 10.15953/j.1004-4140.2015.24.02.01
Citation: PU Ren-wang, LI Zhi-yong, LIU Yi-jun, LIU Jing-hong, GE Ying, LIU Ai-lian. Optimizing Abdominal Spectral CT Angiography Imaging with Double Low Scan Protocol in Small BMI Patients[J]. CT Theory and Applications, 2015, 24(2): 153-159. DOI: 10.15953/j.1004-4140.2015.24.02.01

中小体质指数患者腹部能谱CT血管成像双低扫描方案优化

基金项目: 

大连市科技计划项目(2013E15SF165)

详细信息
    作者简介:

    浦仁旺(1980-),男,研究生学历,大连医科大学附属第一医院放射科主管技师,主要从事影像质量控制等方面研究,Tel:18098876977,E-mail:purenwang777@163.com;刘义军(1963-),男,大连医科大学教授,主要从事影像质量控制研究,Tel:18098877000,E-mail:yijunliu1965@126.com。

    通讯作者:

    刘义军(1963-),男,大连医科大学教授,主要从事影像质量控制研究,Tel:18098877000,E-mail:yijunliu1965@126.com。

  • 中图分类号: TP391.41

Optimizing Abdominal Spectral CT Angiography Imaging with Double Low Scan Protocol in Small BMI Patients

  • 摘要: 目的:探讨腹部能谱CT血管成像双低扫描方案的可行性和应用价值。方法:前瞻性收集疑腹部病变需行全腹血管CT成像BMI≤25的患者367例。首先按照首诊时间分实验组和对照组,再根据体质指数(BMI)分成两个亚组,BMI≤22为实验1组或对照1组,22<BMI≤25为实验2组或对照2组。扫描参数:实验1组(80kVp、50%ASIR、270mgI/mL),实验2组(100kVp、50%ASIR、270mgI/mL),对照1组(120kVp、FBP、350mgI/mL),对照2组(120kVp、FBP、350mgI/mL)。对比各组腹主动脉CT值,CNR,FOM,CTDI<sub<vol</sub<,对比剂碘含量及肾动脉图像质量评分。结果:腹主动脉CT值:实验1组、实验2组分别为(601.75±67.11)HU和(459.87±49.17)HU,对照1组、对照2组分别为(436.55±84.12)HU和(432.15±87.68)HU,实验1组<对照1组,差异具有统计学意义(<i<P</i<值<0.05)。CNR:实验1组、实验2组分别为(19.01±2.66)和(15.24±2.52),对照1组、对照2组分别为(12.42±2.68)和(10.24±2.22),实验1组<对照1组,实验2组<对照2组,差异均有统计学意义(<i<P</i<<0.05)。FOM:实验1组、实验2组分别为(69.72±29.75)和(33.44±8.87),对照1组、对照2组分别为(20.08±8.05)和(15.21±10.12),实验1组<对照1组,实验2组<对照2组,差异均有统计学意义(<i<P</i<值<0.05)。CTDI<sub<vol</sub<:实验1组、实验2组为(5.41±1.38)mGy和(6.98±1.49)mGy,对照1组、对照2组为(9.87±2.97)mGy和(12.02±5.21)mGy,实验1组较对照1组降低45.19%(4.46/9.87)、实验2组较对照2组降低41.93%(5.04/12.02)。实验组、对照组的碘对比剂浓度分别为270mgI/mL和350mgI/mL,实验组降低22.86%(80/350)。肾动脉血管评分:实验1组、实验2组分别为(4.61±0.47)和(4.22±0.59),对照1组、对照2组分别为(3.73±0.72)和(3.93±0.66),实验1组<对照1组,差异具有统计学意义(<i<P</i<<0.05);实验2组与对照2组间差异无统计学意义(<i<P</i<值<0.05)。结论:针对中小体质指数患者,双低扫描方案腹部能谱CT血管成像在保证图像质量的同时可以大幅度地降低辐射剂量和碘对比剂含量,适于推广临床应用。
    Abstract: Purpose: To explore the feasibility and application value of abdominal spectral CT angiography imaging with double low scan protocol. Methods: Total of 367 patients with the BMI ≤ 25 kg/m<sup<2</sup< who were suspected abdominal disease was performed abdominal CT angiography imaging prospectively. Firstly, these patients were divided into experience group and control group according to the first time of treatment and then were divided into two subgroups according to the BMI: Experience 1 group or control 1 group(BMI ≤ 22) and experience 2 group or control 2 group(22 BMI ≤ 25). The scan protocols as follows: Experience 1 group(80 kVp, 50% ASIR, 270 mgI/mL), experience 2 group(100 kVp, 50% ASIR, 270 mgI/mL), control 1 group(120 kVp, FBP, 350 mgI/mL), control 2 group(120 kVp, FBP, 350 mgI/mL). To compare the CT values of aorta abdominalis, CNR, FOM, CDIvol, iodine content of contrast agent and imaging quality score of renal arteries. Results: The CT values of aorta abdominalis of group experience 1, experience 2, control 1, control 2were(601.75 ±67.11) HU,(459.87 ±49.17) HU,(436.55 ±84.12) HU,(432.15 ±87.68), respectively and CT values of groups experience were higher than that of groups control(<i<P</i<<0.05). The CNR of group experience 1, experience 2, control 1, control 2 were(19.01 ±2.66),(15.24 ±2.52),(12.42 ±2.68),(10.24 ±2.22), respectively and CNR of groups experience were higher than that of groups control(<i<P</i<<0.05). The FOM of group experience 1, experience 2, control 1, control 2 were(69.72 ±29.75),(33.44 ±8.87),(20.08 ±8.05),(15.21 ±10.12), respectively and FOM of groups experience were higher than that of groups control(<i<P</i<<0.05). The CTDI<sub<vol</sub< of group experience 1, experience 2, control 1, control 2 were(5.41 ±1.38) mGy,(6.98 ±1.49) mGy,(9.87 ±2.97) mGy,(12.02 ±5.21) mGy, respectively and CTDI<sub<vol</sub< of group experience 1 was reduced by 45.19%(4.46/9.87) than that of control 1 and experience 2 was reduced by 41.93%(5.04/12.02) than that of control 2. The iodine Concentration of group experience and group control was 270 mgI/mL and 350 mgI/mL respectively. The iodine Concentration of group experience was reduced by 22.86%(80/350). The scores of renal arteries of group experience 1, experience 2, control 1, control 2 were(4.61 ±0.47),(4.22 ±0.59),(3.73 ±0.72),(3.93 ±0.66), respectively. The score of group experience 1 was higher than that of group control 1(<i<P</i<<0.05) and there was no statistical significance between group experience 2 and group control 2. Conclusion: The abdominal spectral CT angiography imaging with double low scan protocol can reduce radiation dose and iodine content sharply for the patients with small BMI, and which will be applied to clinic.
  • 期刊类型引用(9)

    1. 颜颖,魏巍,宋丽君,管文敏,张婷婷,孙婧,安冉,杨正汉,魏璇,王振常. 人工智能辅助诊断软件探究新型冠状病毒肺炎核酸转阴后的肺部CT表现及其与入院时临床分型的关系. 临床和实验医学杂志. 2024(04): 337-340 . 百度学术
    2. 刘瑞,武婷婷,勾少波,薛瑞红,贾燕茹,柴军. 不同时期新型冠状病毒感染胸部CT磨玻璃影的临床意义探讨. CT理论与应用研究. 2023(03): 339-346 . 本站查看
    3. 谷辛稼,陈一民. 基于U-Net的COVID-19病灶医学影像ZMINet分割模型. 计算机应用与软件. 2023(08): 235-243 . 百度学术
    4. 张凯,柴军,刘瑞,赵建华,王璟琛. 人工智能定量分析新型冠状病毒感染不同病毒变异株CT特征. CT理论与应用研究. 2023(05): 595-602 . 本站查看
    5. 刘瑞,武婷婷,勾少波,薛瑞红,贾燕茹,柴军. 新型冠状病毒感染不同毒株的CT表现演变与临床转归的相关性分析. CT理论与应用研究. 2023(05): 627-635 . 本站查看
    6. 郝琪,刘晓燕,张妍,李兴鹏,张怡梦,刘梦珂,张晓杰,李玲,郭佳,杜常月,孙莹,霍萌,张明霞,刘薇,段永利,段淑红,王仁贵. 胸部薄层CT平扫对于重型新型冠状病毒感染的诊断价值. CT理论与应用研究. 2023(05): 675-683 . 本站查看
    7. 张海平,吴晓华,赵田瑞,贺毅,杨正汉. 急性肺动脉栓塞继发肺梗死CT特征分析. CT理论与应用研究. 2022(02): 227-235 . 本站查看
    8. 王亮,王鹏,侯晓圆,张俊修,李绍旦,杨明会. 重型和危重型新型冠状病毒肺炎病机特点探析. 山东中医药大学学报. 2022(05): 587-592 . 百度学术
    9. 肖仕刚. 疫情管控事急从权“闭环管理”之应急法治回顾再检视. 贵州工程应用技术学院学报. 2022(04): 58-66 . 百度学术

    其他类型引用(2)

计量
  • 文章访问数:  782
  • HTML全文浏览量:  3
  • PDF下载量:  2
  • 被引次数: 11
出版历程
  • 收稿日期:  2014-12-15
  • 网络出版日期:  2022-12-05

目录

    /

    返回文章
    返回
    x 关闭 永久关闭