ISSN 1004-4140
CN 11-3017/P

双源CT对冠脉搭桥术后桥血管评价的Meta分析

杨涛, 顾静华, 李新明

杨涛, 顾静华, 李新明. 双源CT对冠脉搭桥术后桥血管评价的Meta分析[J]. CT理论与应用研究, 2017, 26(3): 285-290. DOI: 10.15953/j.1004-4140.2017.26.03.04
引用本文: 杨涛, 顾静华, 李新明. 双源CT对冠脉搭桥术后桥血管评价的Meta分析[J]. CT理论与应用研究, 2017, 26(3): 285-290. DOI: 10.15953/j.1004-4140.2017.26.03.04
YANG Tao, GU Jing-hua, LI Xin-ming. Meta Analysis on Graft Vessels Evaluation after Coronary Artery Bypass Grafting by Dual Source CT[J]. CT Theory and Applications, 2017, 26(3): 285-290. DOI: 10.15953/j.1004-4140.2017.26.03.04
Citation: YANG Tao, GU Jing-hua, LI Xin-ming. Meta Analysis on Graft Vessels Evaluation after Coronary Artery Bypass Grafting by Dual Source CT[J]. CT Theory and Applications, 2017, 26(3): 285-290. DOI: 10.15953/j.1004-4140.2017.26.03.04

双源CT对冠脉搭桥术后桥血管评价的Meta分析

基金项目: 

上海市卫计委学科建设项目(ZK2015A13)

详细信息
    作者简介:

    杨涛(1970-),男,医学博士,上海健康医学院附属周浦医院影像科副主任医师、副教授、硕士研究生导师。第十四届中华放射学会MRI专业委员会神经学组委员,上海市浦东新区放射专业委员会委员。主要从事中枢神经系统及心血管影像学诊断,Tel:021-68335590(2182),E-mail:yangtao2004yan@126.com;李新明(1963-),男,医学博士,上海健康医学院附属周浦医院心内科主任医师、教授、博士研究生导师,主要从事缺血性心脏病及结构性心脏病的介入治疗及影像评估等方面的研究,Tel:021-68335590。

  • 中图分类号: R812;R445

Meta Analysis on Graft Vessels Evaluation after Coronary Artery Bypass Grafting by Dual Source CT

  • 摘要: 目的:利用循证医学方法,对双源CT评价冠状动脉搭桥术(CABG)后桥血管狭窄程度的价值进行Meta分析。方法:检索CNKI、万方、维普数据库以及Cochrance Library、PubMed、OVID、Embase等外文数据库,搜索双源CT诊断桥血管狭窄程度的诊断性试验。对纳入资料使用Meta-disc1.4软件进行分析计算,计算合并敏感度、特异度和诊断比值比。结果:最终入选5篇文献,其合并敏感度、特异度和诊断比值比分别为99%、99%、4984,受试者工作特征曲线下面积为99.84%。结论:双源CT对于CABG后桥血管的评价具有很高的诊断效能和临床意义。
    Abstract: Objective: To use the method of evidence-based medicine, Meta analysis of bridge stenosis value evaluation of dual source CT coronary artery bypass surgery. Methods: Retrieval of foreign language databases of CNKI, Wanfang, VIP database and the Cochrane Library, PubMed, Ovid, Embase etc, the search of dual source CT in the diagnosis of graft stenosis diagnostic test. Use Meta-disc 1.4 software to analyze and calculate the data, and calculate the sensitivity, specificity and diagnostic odds ratio. Results: 5 papers were selected, and their combined sensitivity, specificity and diagnostic odds ratio were 99%, 99% and 4 984, respectively. The area under the receiver operating characteristic curve was 99.84%. Conclusion: Dual source CT has clinical significance in diagnosis and high efficiency for the evaluation of bridge vessels after CABG.
  • 期刊类型引用(3)

    1. 孙兆男,王霄英. 基于CAD-RADS~(TM)的冠状动脉CTA结构式报告的构建. 放射学实践. 2022(05): 644-647 . 百度学术
    2. 牛艳,靳春荣. 冠脉搭桥后心脏结构与功能CT影像学评价和临床相关影响因素分析. 影像科学与光化学. 2021(02): 305-309 . 百度学术
    3. 刘飞,周自强,吴明营,鲜军舫. 电子计算机断层扫描血管成像技术在冠状动脉旁路移植术后桥血管评价中的应用. 首都医科大学学报. 2019(01): 150-156 . 百度学术

    其他类型引用(0)

计量
  • 文章访问数:  495
  • HTML全文浏览量:  1
  • PDF下载量:  4
  • 被引次数: 3
出版历程
  • 收稿日期:  2017-02-20
  • 网络出版日期:  2022-11-27

目录

    /

    返回文章
    返回
    x 关闭 永久关闭