ISSN 1004-4140
CN 11-3017/P

弹性波CT在高压摆喷防渗墙质量检测中的应用

赵祥, 杨磊, 冷元宝, 潘纪顺

赵祥, 杨磊, 冷元宝, 潘纪顺. 弹性波CT在高压摆喷防渗墙质量检测中的应用[J]. CT理论与应用研究, 2017, 26(5): 559-564. DOI: 10.15953/j.1004-4140.2017.26.05.04
引用本文: 赵祥, 杨磊, 冷元宝, 潘纪顺. 弹性波CT在高压摆喷防渗墙质量检测中的应用[J]. CT理论与应用研究, 2017, 26(5): 559-564. DOI: 10.15953/j.1004-4140.2017.26.05.04
ZHAO Xiang, YANG Lei, LENG Yuan-bao, PAN Ji-shun. The Application of Elastic Wave CT to Qualities Detection of High Pressure Swing Jet Cut-off Walls[J]. CT Theory and Applications, 2017, 26(5): 559-564. DOI: 10.15953/j.1004-4140.2017.26.05.04
Citation: ZHAO Xiang, YANG Lei, LENG Yuan-bao, PAN Ji-shun. The Application of Elastic Wave CT to Qualities Detection of High Pressure Swing Jet Cut-off Walls[J]. CT Theory and Applications, 2017, 26(5): 559-564. DOI: 10.15953/j.1004-4140.2017.26.05.04

弹性波CT在高压摆喷防渗墙质量检测中的应用

基金项目: 

黄河水利科学研究院基本科研业务费专项项目(HKY-JBYW-2016-37)。

详细信息
    作者简介:

    赵祥*(1992-),男,华北水利水电大学资源与环境学院地球物理专业硕士研究生,主要的研究方向是应用地球物理及工程物探,Tel:18237160187,E-mail:1825819700@qq.com。

  • 中图分类号: P315

The Application of Elastic Wave CT to Qualities Detection of High Pressure Swing Jet Cut-off Walls

  • 摘要: 针对高压摆喷防渗墙目前检测存在的问题,本文介绍了弹性波CT技术检测的基本原理和过程,对某水库大坝高压摆喷防渗墙的质量进行检测,并对部分墙体进行钻孔取芯及注水试验验证,通过实例分析,结果表明弹性波CT技术在防渗墙质量检测中具有检测速度快,检测准确度高的优点,在防渗墙质量无损检测中具有广阔的应用前景。
    Abstract: Aiming at the problems existing in the current detection of high-pressure swing jet grouting cut-off wall, in this paper, the basic principle and process of elastic wave CT detection technology are introduced. The quality of high-pressure swing jet grouting cut-off wall of reservoir dam is tested, and core drilling and water injection test are applied in the part of the wall. The results show that the elastic wave CT has the advantages of fast detection speed and high detection accuracy in the quality detection of the cut-off wall, and it has a broad application prospect in the non-destructive testing of the cut-off walls quality.
  • 期刊类型引用(5)

    1. 刘素萍,魏玲玲. 针对性护理干预在CT增强扫描中的应用效果研究. 现代医药卫生. 2022(04): 681-684 . 百度学术
    2. 吴建峰,李林静,方春,王豪杰,祝峰. 个体化碘对比剂注射速率方案在肝脏增强CT中提高增强质量一致性的价值. 中国医师杂志. 2022(03): 456-458 . 百度学术
    3. 龚剑英,谢军,喻科,颜得新. 基于身体指数测量计算肝脏CT增强扫描个体化碘对比剂方案的研究. 中国CT和MRI杂志. 2022(10): 84-86 . 百度学术
    4. 董相宇,方挺松,袁健祥,梁振华,李均洪. 基于BSA及固定碘速率探讨不同浓度对比剂对肝静脉CT成像效果的影响. CT理论与应用研究. 2021(04): 466-476 . 本站查看
    5. 孟晶晶,韩耀华,孙大明. 对比剂浓度和患者门静脉CT影像质量的关系分析. 河北医学. 2021(09): 1486-1490 . 百度学术

    其他类型引用(0)

计量
  • 文章访问数:  584
  • HTML全文浏览量:  4
  • PDF下载量:  6
  • 被引次数: 5
出版历程
  • 收稿日期:  2017-03-27
  • 网络出版日期:  2022-12-01
  • 发布日期:  2017-10-24