ISSN 1004-4140
CN 11-3017/P

CARE Dose 4D技术联合低kV及低剂量对比剂在MSCT头颈CTA应用

梁洪生, 陈进军, 陈小宇, 梁宇豪, 欧剑扬, 马关华

梁洪生, 陈进军, 陈小宇, 梁宇豪, 欧剑扬, 马关华. CARE Dose 4D技术联合低kV及低剂量对比剂在MSCT头颈CTA应用[J]. CT理论与应用研究, 2017, 26(5): 605-612. DOI: 10.15953/j.1004-4140.2017.26.05.10
引用本文: 梁洪生, 陈进军, 陈小宇, 梁宇豪, 欧剑扬, 马关华. CARE Dose 4D技术联合低kV及低剂量对比剂在MSCT头颈CTA应用[J]. CT理论与应用研究, 2017, 26(5): 605-612. DOI: 10.15953/j.1004-4140.2017.26.05.10
LIANG Hong-sheng, CHEN Jin-jun, CHEN Xiao-yu, LIANG Yu-hao, OU Jian-yang, MA Guan-hua. Dose 4D CARE Technology Combined with Low kV and Low Dose Contrast Agent in MSCT Head and Neck Vascular Imaging Applications[J]. CT Theory and Applications, 2017, 26(5): 605-612. DOI: 10.15953/j.1004-4140.2017.26.05.10
Citation: LIANG Hong-sheng, CHEN Jin-jun, CHEN Xiao-yu, LIANG Yu-hao, OU Jian-yang, MA Guan-hua. Dose 4D CARE Technology Combined with Low kV and Low Dose Contrast Agent in MSCT Head and Neck Vascular Imaging Applications[J]. CT Theory and Applications, 2017, 26(5): 605-612. DOI: 10.15953/j.1004-4140.2017.26.05.10

CARE Dose 4D技术联合低kV及低剂量对比剂在MSCT头颈CTA应用

详细信息
    作者简介:

    梁洪生(1982-),男,广东省肇庆市中医院医学影像(放射)科主治医师,主要从事心胸影像及血管影像诊断工作,Tel:0758-2895177,E-mail:immonok2005@163.com;陈进军*(1966-),男,广东省肇庆市中医院医学影像(放射)科主任医师,主要从事胸腹部影像诊断及介入治疗工作研究,Tel:0758-2895177,E-mail:ctping@163.com。

  • 中图分类号: R812;R445

Dose 4D CARE Technology Combined with Low kV and Low Dose Contrast Agent in MSCT Head and Neck Vascular Imaging Applications

  • 摘要: 目的:探讨128层螺旋CT头颈部血管成像(CTA)应用CARE Dose 4D技术联合低剂量对比剂优化扫描方案的可行性及价值。方法:前瞻性选取接受头颈部血管成像检查的60例患者,随机分为对照组(A组)和双低剂量组(B组),每组各30例。对照组(A组)管电压120 kV,采用CARE Dose 4D技术参考管电流120 mA,对比剂用量65 mL;双低剂量组(B组)管电压80 kV,采用CARE Dose 4D技术参考管电流120 mA,对比剂用量45 mL。测量双侧颈总动脉、双侧颈内动脉及双侧大脑中动脉M1段CT值、噪声、信噪比(SNR)进行客观图像质量评价。由两名高年资主治医师采用双盲法进行图像质量评分评价。对比A组与B组间辐射剂量。结果:两名主治医师对动脉图像量质评分的一致性较高(Kappa=0.782,P<0.05)。两组动脉图像质量评分、SNR比较,差异无统计学意义(P>0.05)。双低剂量组各动脉强化CT值均高于对照组;双低剂量组容积CT剂量指数、剂量长度乘积和有效剂量均明显低于对照组;差异均具有统计学意义(P<0.05)。结论:128层MSCT头颈血管成像应用低kV及CARE Dose 4D技术联合低剂量对比剂扫描方案,不仅辐射剂量降低68%,同时造影剂用量降低30.7%,降低对比剂危害风险并节省费用,保证诊断图像质量值得临床推广。
    Abstract: Objective: To investigate the feasibility and value of 128 slice spiral CT angiography (CTA) using CARE Dose 4D techniques combined with low dose contrast agent to optimize the scanning protocol. Methods: a total of 60 patients with head and neck vascular imaging were selected and randomly divided into control group (A group) and low dose group (B group), each group with a total of 30 cases. The control group (A group) 120 kV tube voltage, using CARE Dose4D technology reference tube current of 120 mA, dosage of contrast agent was 65 ml; double low dose group (B group) tube voltage 80 kV, using CARE Dose4D technology reference tube current of 120 mA, contrast agent dosage is 45 ml. Objective to evaluate the image quality of CT, noise and signal to noise ratio (SNR) of bilateral common carotid artery, bilateral internal carotid artery and bilateral middle cerebral artery (M1). The evaluation of image quality was performed by two double blind methods. Comparison of radiation dose between group A and group B. Results: two attending physicians had a higher consistency of P < 0.05 (Kappa=0.782). There was no significant difference between the two groups in arterial image quality score and SNR score (P > 0.05). The double low dose group arterial enhancement CT value were higher than the control group; double low dose volume CT dose index and dose length product and effective dose were significantly lower than the control group; the differences were statistically significant (P < 0.05). Conclusion: low kV imaging using 128 slice MSCT and CARE Dose 4D head and neck vascular technique combined with low dose contrast scanning scheme, not only reduce the radiation dose of 68%, while the amount of contrast agent is reduced by 30.7%, reduce the contrast agent risk and cost savings, ensure the diagnostic image quality is worthy of promotion.
  • 期刊类型引用(15)

    1. 张艳伟,范恒全,张学谦,陶亚飞,酒晓林,牛存钊,祝青松,张戈. 高浓度对比剂联合低剂量扫描方案行头颈动脉CTA扫描的应用效果研究. 医学影像学杂志. 2024(08): 22-25 . 百度学术
    2. 潘红红,陈伟彬. 高浓度对比剂联合“三低”方案行颈动脉CTA可行性分析. 华北理工大学学报(医学版). 2023(02): 90-95 . 百度学术
    3. 邓婕,林智胜,王娜琴. 低辐射剂量、低对比剂用量和低注射流速在心血管CTA的可行性研究. 中国CT和MRI杂志. 2022(03): 58-61 . 百度学术
    4. 沈文超,乔刚,赵磊. 320排CT头颈部血管成像应用CARE Dose 4D技术联合低剂量对比剂优化扫描方案的价值. 河北医药. 2022(02): 269-271 . 百度学术
    5. 王继荣,杜海坤,席永国,孙小芹. 西宁地区低辐射剂量、低对比剂用量和低流速在主动脉CTA中的应用. 青海医药杂志. 2022(11): 1-5 . 百度学术
    6. 禹烜,王臣,杜祥颖,齐志刚,卢洁. 自动管电压选择技术在双源CT大螺距心脑一体化血管成像中的应用价值. 中华老年心脑血管病杂志. 2021(05): 455-458 . 百度学术
    7. 崔小巍. 碘美普尔注射液在头颈部CTA扫描检查中的应用效果. 现代医用影像学. 2019(07): 1569-1570 . 百度学术
    8. 王玉勇,侯蕾. 分析低电压、低碘对比剂剂量应用于头颈CTA患者的临床效果. 影像研究与医学应用. 2019(15): 130-131 . 百度学术
    9. 李树昌,刘景琨,龚远达,隋如新. 70 kVp结合SAFIRE在头颈部CTA中的应用价值. 大连医科大学学报. 2019(05): 421-425 . 百度学术
    10. 刘星,陈新月,赵喜,张永高,刘甲,董雷刚,高剑波,刘杰. 第3代双源CT非线性融合技术在低对比剂用量及低注射流率注射条件下在腹主动脉成像中的应用研究. 重庆医科大学学报. 2019(10): 1327-1331 . 百度学术
    11. 张小勇,王頔,曾宪春,崔学龙,李文航,伍瑶斌,王荣品. 个体化低剂量大螺距扫描在头颈心血管一站式检查中的应用. 临床放射学杂志. 2019(10): 1971-1975 . 百度学术
    12. 邹建华,周一妍,赵雁奇. 低辐射剂量扫描联合低剂量造影剂技术在64排小宝石CT冠脉成像中的可行性分析. 影像研究与医学应用. 2019(22): 83-84 . 百度学术
    13. 王俊,陆皓,程祝忠,陈世容,肖定琼,赵檬. 一体式定位像和分段式定位像配合CARE Dose 4D技术控制PET检查者辐射剂量的比较. 现代仪器与医疗. 2019(05): 52-55 . 百度学术
    14. 王国树,吕发金,周旸,孙静坤. 非线性融合技术在头颈部CTA中的价值:体模实验. 中国医学影像技术. 2018(07): 1085-1089 . 百度学术
    16. 徐志宾,黄祖和,梁纹菁. 多层螺旋CT高浓度低剂量造影剂头颈部血管成像的应用研究. 家庭医药.就医选药. 2019(01): 71-72 . 百度学术

    其他类型引用(2)

计量
  • 文章访问数:  859
  • HTML全文浏览量:  20
  • PDF下载量:  6
  • 被引次数: 17
出版历程
  • 收稿日期:  2017-03-23
  • 网络出版日期:  2022-12-01
  • 发布日期:  2017-10-24

目录

    /

    返回文章
    返回
    x 关闭 永久关闭