ISSN 1004-4140
CN 11-3017/P

肠管周围爬行脂肪CT值变化对克罗恩活动性的诊断价值

高贇, 管雪妮, 戎兰, 周磊, 梁宗辉

高贇, 管雪妮, 戎兰, 周磊, 梁宗辉. 肠管周围爬行脂肪CT值变化对克罗恩活动性的诊断价值[J]. CT理论与应用研究, 2019, 28(4): 477-484. DOI: 10.15953/j.1004-4140.2019.28.04.09
引用本文: 高贇, 管雪妮, 戎兰, 周磊, 梁宗辉. 肠管周围爬行脂肪CT值变化对克罗恩活动性的诊断价值[J]. CT理论与应用研究, 2019, 28(4): 477-484. DOI: 10.15953/j.1004-4140.2019.28.04.09
GAO Yun, GUAN Xueni, RONG Lan, ZHOU Lei, LIANG Zonghui. Diagnostic Value of CT Value of Creeping Fat around Intestinal Tube for Crohn's Activity[J]. CT Theory and Applications, 2019, 28(4): 477-484. DOI: 10.15953/j.1004-4140.2019.28.04.09
Citation: GAO Yun, GUAN Xueni, RONG Lan, ZHOU Lei, LIANG Zonghui. Diagnostic Value of CT Value of Creeping Fat around Intestinal Tube for Crohn's Activity[J]. CT Theory and Applications, 2019, 28(4): 477-484. DOI: 10.15953/j.1004-4140.2019.28.04.09

肠管周围爬行脂肪CT值变化对克罗恩活动性的诊断价值

基金项目: 

上海市静安区医学科研课题《多模态磁共振成像对炎症性肠病活动性的评估研究》(2016MS03);上海市卫计委科研项目《磁共振及其功能成像技术在炎症性肠病活动性评价中的应用研究》(201640064);国家自然科学基金面上项目《基于多模态脑功能磁共振的炎症性肠病脑-肠互动机制研究及诊断模型构建》(81871423)。

详细信息
    作者简介:

    高贇(1988-),女,硕士,上海市静安区中心医院放射科住院医师,主要从事医学影像的CT及MR诊断工作,Tel:021-61578004,E-mail:yungao.dragon@outlook.com;梁宗辉*(1969-),男,博士,硕士生导师,主任医师,上海市静安区中心医院(复旦大学附属华山医院静安分院)放射科主任、介入科主任,主要从事神经影像学和腹部影像学诊断研究,Tel:021-61578005,E-mail:liangzh@vip.163.com;戎兰*(1967-),女,复旦大学附属华山医院消化科主任医师,副教授,主要从事炎症性肠病的诊疗及机制研究,Tel:021-52889999,E-mail:ronglr@hotmail.com。

  • 中图分类号: R812

Diagnostic Value of CT Value of Creeping Fat around Intestinal Tube for Crohn's Activity

  • 摘要: 目的:探讨克罗恩病活动性病变患者系膜根部爬行脂肪CT值变化的特点。方法:选取2016年1月至2019年3月上海市静安区中心医院收治的31例克罗恩病活动期患者为研究对象,同时随机选取年龄、性别相匹配的克罗恩病非活动期患者/健康人群作为对照。收集临床资料包括小肠CT增强检查、小肠镜检查及其病理结果、临床免疫抑制治疗疗效。结果:克罗恩病活动期患者31例(男26例,女5例),对照组31例(男22例,女9例)。与对照组相比,克罗恩病活动期患者系膜根部爬行脂肪密度增高,增强后随时间延长可出现持续轻度强化。结论:克罗恩病病变肠管周围的爬行脂肪于疾病活动期可出现密度增高、持续性强化的特点,因此肠管周围爬行脂肪的CT值变化对克罗恩病的活动性具有诊断价值。
    Abstract: Objective: Investigate the CT value changes of creeping fat around the intestinal segment in Crohn's disease(CD).Methods: From January 2010 to March 2019, 31 patients with active CD(study group) and 31 age and gender matched inactive CD patients/healthy people(control group) were enrolled in the study.The people of study group and control group were tested for CT values of mesentery near the inflammatory intestinal wall, including CT values in plain scan, arterial phase, venous phase and delayed phase.Clinical data including enteroscopy and its pathological results, and clinical immunosuppressive therapy were collected.Results: There were 31 patients(26 males and 5 females) with active Crohn's disease(CD) in the study group.There were 31 patients(22 males and 11 females) in control group.The CT value of creeping fat in patients with Crohn's disease in active stage is higher than that in inactive CD patients/healthy people, and there may be sustained mild enhancement after enhancement over time.Conclusion: The creeping fat along the mesenteric border of bowel inflamed segments of CD can be denser and continuously strengthened during the active stage of the disease, so the change of CT value of the creeping fat around the intestinal tube has diagnostic value for Crohn's disease activity.
  • 期刊类型引用(2)

    1. 林望望,黄伟. 双能量CT对肠系膜脂肪在克罗恩病活动性评估的价值研究. 重庆医学. 2021(03): 388-392 . 百度学术
    2. 李璐,梁宗辉. 腹部脂肪定量评估在克罗恩病中的临床应用进展. 国际医学放射学杂志. 2021(01): 72-75 . 百度学术

    其他类型引用(1)

计量
  • 文章访问数:  381
  • HTML全文浏览量:  4
  • PDF下载量:  8
  • 被引次数: 3
出版历程
  • 收稿日期:  2019-05-16
  • 网络出版日期:  2021-11-07
  • 发布日期:  2019-08-24

目录

    /

    返回文章
    返回
    x 关闭 永久关闭