ISSN 1004-4140
CN 11-3017/P

影像组学在胃癌患者预后预测中的应用进展

冯涵, 谢明国

冯涵, 谢明国. 影像组学在胃癌患者预后预测中的应用进展[J]. CT理论与应用研究(中英文), 2025, 34(4): 714-719. DOI: 10.15953/j.ctta.2024.040.
引用本文: 冯涵, 谢明国. 影像组学在胃癌患者预后预测中的应用进展[J]. CT理论与应用研究(中英文), 2025, 34(4): 714-719. DOI: 10.15953/j.ctta.2024.040.
FENG H, XIE M G. Application Advancements of Radiomics in Predicting the Prognosis of Patients with Gastric Cancer[J]. CT Theory and Applications, 2025, 34(4): 714-719. DOI: 10.15953/j.ctta.2024.040. (in Chinese).
Citation: FENG H, XIE M G. Application Advancements of Radiomics in Predicting the Prognosis of Patients with Gastric Cancer[J]. CT Theory and Applications, 2025, 34(4): 714-719. DOI: 10.15953/j.ctta.2024.040. (in Chinese).

影像组学在胃癌患者预后预测中的应用进展

基金项目: 

胃癌区域淋巴结转移128层MDCT辐射剂量灌注成像及其临床应用研究(YYZX2020016)。

详细信息
    作者简介:

    冯涵,女,硕士研究生,主要研究方向为腹部肿瘤,E-mail:840926802@qq.com

    通讯作者:

    谢明国✉,男,主任医师、硕士生导师,主要研究方向为神经系统MR,E-mail:xmg6806@163.com

  • 中图分类号: R 735.2;R 445

Application Advancements of Radiomics in Predicting the Prognosis of Patients with Gastric Cancer

  • 摘要:

    胃癌是发病率和死亡率较高的肿瘤之一,术前进行精准的预测对预后至关重要。影像组学是一种新型、有效的医学图像解码技术,可以从影像图像中提取难以定量描述的高维特征,并提供肿瘤异质性的评估以及肿瘤微环境的功能信息,在预测胃癌患者的预后中有较高的价值。本文就影像组学在胃癌患者的预后预测中的应用进展进行综述。

    Abstract:

    Gastric cancer has high morbidity and mortality; thus, accurate prognostic predictions before surgery are very important. Radiomics is a new and effective medical image technology that extracts high-dimensional features that are difficult to describe quantitatively from images and provides an evaluation of tumor heterogeneity and functional information on the tumor microenvironment, which has a high value in predicting the prognosis of patients with gastric cancer. This article reviews the application of radiomics for the prognostic prediction of patients with gastric cancer.

  • 急性肺栓塞(pulmonary embolism,PE)具有较高的发病率及病死率,是常见的三大致死性心血管疾病之一。CT肺动脉成像(computed tomography pulmonary arteriography,CTPA)是确诊PE影像学检查的首选方法[1],具有很高的敏感性和特异性。64排以上CT扫描速度快,CTPA的数据采集时间都可以控制在3 s以内,准确把握肺动脉增强峰值时间是检查成功的关键。CTPA扫描延迟时间的选择目前常用的方法有小剂量团注测试技术和对比剂团注跟踪技术,小剂量团注测试技术操作步骤多,受操作者个人经验影响较大,对比剂团注跟踪技术受限于机器的过渡延迟时间(即ROI到达阈值切换到正式扫描之间的时间),易导致肺静脉过度强化影响肺动脉的观察。

    本研究在两种技术的基础上,通过改良对比剂注射方案,即两段式对比剂同速注射的方法,探讨一种获得优质CTPA成像效果的扫描技术。

    本研究通过首都医科大学附属北京同仁医院伦理委员会的批准(TREC2022-KY037)。收集2022年7月至12月在首都医科大学附属北京同仁医院因怀疑肺栓塞行肺动脉CT增强检查的30例患者作为试验组,其中男17例、女13例,年龄31~87岁,平均(64±16)岁,体重53~84 kg,平均(66.0±8.9)kg,身体质量指数(body mass index,BMI)为(24.03±2.61)kg/m2,增强扫描时采用两段式对比剂同速注射结合团注跟踪技术的方法。

    收集2021年1月至2021年12月间30例患者为对照组,男16例、女14例,年龄34~85岁,平均(61±14)岁,体重50~85 kg,平均(65.0±10.5)kg,BMI为(23.51±2.56)kg/m2,采用小剂量团注测试技术的方法。

    排除标准:肝肾功能不全及严重心功能不全;既往碘对比剂过敏者,妊娠、甲状腺亢进、癫痫及严重哮喘患者;图像中存在金属、呼吸运动等伪影明显影响诊断;体重大于85 kg的患者未纳入本研究。

    使用Philips IQon双层探测器光谱CT机和拜耳双筒高压注射器(StellantD-CE超级版),对比剂为碘普罗胺注射液(拜耳医药保健有限公司),碘浓度370 mg/mL。患者仰卧于CT扫描床上,双手上举,放于头部上方,根据患者情况选择左则或右侧肘静脉注射对比剂。

    试验组患者的监测兴趣区(region of interest,ROI)置于肺动脉主干,设定阈值为100 HU。对比剂和生理盐水注射顺序:①经 A注射筒注射对比剂10 mL;②经 B筒注射生理盐水30 mL;③经 A筒注射对比剂20 mL;④经 B筒注射生理盐水30 mL。上述注射步骤均按设定顺序由高压注射器自动无间隔完成,对比剂和生理盐水注射流率均为5 mL/s。在开始注射第1段对比剂时同时跟踪肺动脉主干CT值,达到设定阈值后延迟10 s开始扫描(图1)。

    图  1  两段式对比剂注射方法,注射流率均为5 mL/s,两段对比剂开始注射时间间隔8 s,第1段对比剂达到设定阈值后10 s相当于第2段对比剂达到阈值后2 s
    Figure  1.  In the two-stage injection method, the injection flow rate was 5 mL/s, and the interval between the start of the two-stage contrast injection was 8 s; 10 s after the first stage of contrast reaches the set threshold is equivalent to 2 s after the second stage of contrast reaches the threshold

    对照组患者使用小剂量团注测试技术。监测ROI同样置于肺动脉主干,注射流率5 mL/s,先经A筒注射对比剂10 mL,再经B筒注射生理盐水30 mL,注射开始同时不间断同层连续扫描,每1.5 s扫描1次,共扫描15次,获得肺动脉主干ROI的时间-密度曲线,测量增强峰值时间,本研究中测得的肺动脉主干对比剂达峰时间为7~13 s,平均(10.8±0.8)s。以此达峰时间+1 s作为延迟时间,然后经A筒注射20 mL对比剂,经B筒注射30 mL生理盐水,以此延迟时间进行扫描。

    CTPA扫描参数:使用螺旋扫描方式,管电压120 kV,旋转时间0.27 s,使用Philips IQon CT自带管电流自动调制技术(DoseRight),DoseRight Index选择22;参考有效管电流量129 mAs/层,准直宽度为64×0.625 mm,螺距1.015,使用迭代重建(iDose),迭代等级选择3;滤过核选择Standard(B),重建图像层厚1 mm,层间距1 mm,视野300~350 mm,依患者胸部大小调整,矩阵512×512,窗宽窗位使用600/100。扫描范围从肺尖至膈顶,所有患者均在扫描前嘱平静呼吸下呼气后屏气扫描。

    将原始薄层图像传至Philips星云工作站,进行多平面重组(multi planar reformation,MPR),获得横断面、冠状面和矢状面图像,同时进行最大密度投影(maximum intensity projection,MIP)。使用容积再现(volume rendering,VR),去骨,结合MIP同时显示肺动脉各段分支。

    两组影像均测量以下血管的CT值:肺动脉主干、右肺动脉、左肺动脉,肺动脉周围分支(右肺上叶动脉、右肺中叶动脉、右肺下叶动脉、左肺上叶动脉、左肺下叶动脉)、肺静脉(右上肺静脉、右下肺静脉、左上肺静脉、左下肺静脉)、注射对比剂侧的锁骨下静脉及升主动脉。如果存在肺栓塞,仅测量未受影响的血管。ROI大小为0.05~0.6 cm2,记录CT值,并计算同侧肺动脉与肺静脉的CT值差,公式为肺动脉CT值-(同侧上肺静脉CT值+下肺静脉CT值)/2。

    由2名具有10年以上诊断经验的副主任医师以盲法分别对试验组和对照组图像质量进行评价。

    根据既往临床诊断经验以4分制标准评价肺动脉图像质量:4分为肺动脉层面CT值≥250 HU,肺动脉及分支血管均显示良好,但是肺动脉与肺静脉CT差值>150 HU,肺静脉略强化,不影响肺动脉分支的鉴别;3分为肺动脉层面CT值≥250 HU,肺动脉及分支血管均显示良好,但是肺动脉与肺静脉CT差值≤150 HU,肺静脉明显强化,影响肺动脉分支的鉴别;2分为150 HU<肺动脉层面CT值<250 HU,肺动脉二、三级血管显影不佳;1分为肺动脉层面 CT值≤150 HU,说明肺动脉强化效果弱,无法明确诊断分支血管。

    采用4分制评分法评价上腔静脉硬化伪影:4分,无硬化伪影;3分,硬化伪影可忽略;2分,硬化伪影明显,但肺动脉可显示,尚能诊断;1分,硬化伪影严重影响肺动脉的显示和诊断。

    采用SPSS 23.0软件进行统计分析,采用Shapiro-Wilk检验对数据行正态性分析,符合正态分布的计量资料用$(\bar{x}\pm s)$表示,不符合正态分布用${M}({Q_1}, {Q_3})$表示。试验组与对照组患者性别比较采用卡方检验;年龄、BMI、血管CT值的比较采用独立样本t检验;肺动脉图像质量评分、上腔静脉硬化伪影评分的比较采用非参数Mann-Whitney U检验。

    两名医师间图像质量主观评价的一致性采用Kappa检验,Kappa值<0.40提示两者一致性差,0.41~0.60为一致性一般,0.61~0.80为一致性好,>0.80为一致性非常好。P<0.05为差异有统计学意义。

    试验组和对照组患者性别、年龄、BMI差异均无统计学意义。试验组和对照组通过CTPA检查诊断为肺栓塞的分别为3例和2例。

    试验组30例患者均获得良好的肺动脉强化效果,3例患者出现肺静脉强化,干扰肺动脉的观察,而对照组有8例患者肺静脉强化明显。试验组肺静脉强化原因是跟踪ROI时因为呼吸运动ROI有的期相不在跟踪层面,导致ROI达到阈值时间延迟。对照组肺静脉强化原因主要是测试达峰时间误差或启动扫描延迟所致(图2)。

    图  2  对照组患者使用小剂量团注测试技术,试验组患者使用两段式对比剂注射结合团注跟踪技术
    (a)和(b)为对照组组患者,(a)横轴位厚层MIP图像,(b)冠状位厚层MIP图像,因扫描启动过晚导致肺静脉强化,肺动脉与肺静脉CT值差值小于150 HU,图像质量评分为3分;(c)和(d)为试验组患者,(c)横轴位厚层MIP图像,(d)冠状位厚层MIP图像,肺静脉略显影,肺动脉处于强化峰值,与肺静脉有良好的对比,CT值差值大于150 HU,图像质量评分为4分。
    Figure  2.  The control groups, using the test bolus technique, and the experimental groups, using a two-stage injection of contrast agent combined with bolus tracking technique

    试验组和对照组所测量血管CT值见表1,其中左肺动脉、右肺上叶动脉、右肺中叶动脉、右肺下叶动脉、左肺上叶动脉、升主动脉CT值差异有统计学意义,试验组CT值大于对照组;肺动脉主干、右肺动脉、左肺下叶动脉、右上肺静脉、右下肺静脉、左上肺静脉、左下肺静脉、锁骨下静脉、右侧动静脉CT值差值、左侧动静脉CT值差值差异无统计学意义。

    表  1  试验组和对照组测量血管的平均值、最小值和最大值的比较
    Table  1.  Comparison of mean, minimum, and maximum values of measured vessels between the experimental and control groups
    测量血管CT值/HU统计检验
    试验组$\bar{x}\pm s$(min~max)对照组$\bar{x}\pm s$(min~max)tP
      肺动脉主干340±50(264~431)312±65(183~483)1.860.067
      右肺动脉339±51(251~435)313±58(180~463)1.860.068
      左肺动脉345±54(252~431)314±57(188~466)2.210.031
      右肺上叶动脉367±62(281~498)329±61(185~497)2.400.020
      右肺中叶动脉359±61(269~468)322±58(202~472)2.390.020
      右肺下叶动脉363±58(268~511)329±61(206~469)2.190.033
      左肺上叶动脉362±54(258~441)330±59(197~467)2.180.033
      左肺下叶动脉362±57(259~457)332±63(195~474)1.890.064
      右上肺静脉137±39(85~225)128±57(40~263)0.740.462
      右下肺静脉132±30(86~192)122±53(45~225)0.860.392
      左上肺静脉137±37(89~226)134±56(42~265)0.200.841
      左下肺静脉135±35(91~228)124±52(40~244)0.900.375
      锁骨下静脉935±250(469~1728)840±303(317~1645)1.320.193
      升主动脉120±21(84~165)71±19(44~120)9.500.000
      右侧动静脉CT值差值204±57(86~289)188±89(-17~374)0.870.389
      左侧动静脉CT值差值210±61(70~301)184±86(6~376)1.310.195
    注:$\bar{x}\pm s$为平均值±标准差,min为最小值,max为最大值。
    下载: 导出CSV 
    | 显示表格

    两名医师对试验组和对照组肺动脉影像质量、上腔静脉硬化伪影评分结果见表2。两名医师间评分结果一致性好(Kappa值均>0.61,表2)。试验组和对照组肺动脉影像质量评分差异无统计学意义;试验组和对照组上腔静脉硬化伪影评分差异无统计学意义。

    表  2  两名医师对试验组和对照组肺动脉影像质量、上腔静脉伪影评分分布和一致性分析结果
    Table  2.  Distribution and consistency of pulmonary artery image quality and superior vena sclerotic artifact scores analyzed by two physicians in the experimental and control groups
    组别医师1/例医师2/例评分
    $({M}({Q}_{1}, t{Q}_{3} ))$
    一致性分析
    4分3分2分1分4分3分2分1分Kappa值P
    肺动脉图像质量评分 
    试验组   22 80023 7004.0(3.5,4.0)0.73<0.001
    对照组   1513201911003.75(3.0,4.0)0.62<0.001
    上腔静脉硬化伪影评分
    试验组    42240 224403.0(3.0,3.0)0.66<0.001
    对照组    22440 219903.0(2.5,3.0)0.63<0.001
    下载: 导出CSV 
    | 显示表格

    优质的CTPA图像是肺动脉及分支充分强化,肺静脉略强化,并与肺动脉有良好的对比,以区分肺动脉和肺静脉,同时上腔静脉没有对比剂硬化伪影或硬化伪影极少,不影响肺动脉的观察[2],这决定了CTPA要在肺动脉达到峰值时,上腔静脉内对比剂峰值已过,同时要在肺静脉充分强化前完成扫描,由于肺动脉循环很快,肺动脉到肺静脉的循环时间仅2~3 s,可利用的增强时间窗非常窄,这就要求对比剂的注射时间短,同时扫描速度要快,而64排CT基本可以将肺动脉扫描时间控制在3 s,因此对比剂用量不需要太多,根据既往研究[2],按照注射流率5 mL/s,20 mL对比剂完全可以满足肺动脉增强要求,但是较短的对比剂注射时间对肺动脉增强峰值的把握提出了较高的要求,准确确定CTPA扫描延迟时间异常关键。

    延迟时间的选择目前常用的方法有小剂量团注测试技术和对比剂团注跟踪技术,小剂量团注测试技术能够有效地反映肺循环信息,有利于把握准确的扫描时机[2-4],但是操作步骤多,且受操作环境及人为因素影响较大,对比剂启动注射与CT启动扫描的一致性很难做到绝对一致,由此产生的误差影响了预实验测试肺动脉增强峰值时间的准确性,并且有的机器并不具备测试达峰时间的程序。对比剂团注跟踪技术作为一种简单有效地方法,普遍应用于各种CT血管成像[5-6],相较于小剂量团注测试技术,对比剂团注跟踪技术更具个性化[7],受患者个体循环差异影响小。

    过渡延迟时间是对比剂团注跟踪技术中一个重要的参数,指的是ROI到达阈值切换到正式扫描之间的时间,这段时间内设备需要完成扫描前准备工作(扫描床移动到扫描起始位置)以及向患者发出检查所需要的呼吸指令,此时间也与设备本身有关,一般在4~7 s。多数研究将ROI置于肺动脉主干[8-9],由于此时间大于肺循环时间,这就导致肺静脉强化,影响肺动脉的观察,同时需要更多的对比剂注射时间以及对比剂用量。

    针对此问题,有研究将上腔静脉及头臂干静脉设为ROI[10-11],虽然肺静脉不成像但是受心功能影响较大,容易造成检查失败。也有学者使用3期团注法对比剂注射方案[12]或多期双流混合注射方案[13],以肺动脉主干为ROI,第Ⅰ期注射混合液的对比剂浓度低,起到达阈值触发扫描的作用,同时注射混合液所用时间抵消触发后启动扫描的时间,第Ⅱ期对比剂到达时开始扫描,第Ⅰ期混合液进入肺静脉强化程度低,对肺动脉的观察不会造成影响,提高了检查的成功率。此方案虽然第一期混合液与第Ⅱ期对比剂注射流率一致,但是对比剂浓度不一致,两期对比剂的相对注射流率不一致,其达峰时间不一样,混合液达到设定阈值的时间过晚仍会导致检查失败发生。

    本研究借鉴CT血管成像中小剂量团注测试技术的一些研究[2-4,7,14-15],这些研究测试达峰时间的小剂量对比剂与进行正式扫描的对比剂都使用了相同的浓度和相同的注射流率。基于此,本研究跟踪肺动脉主干的CT值,将测试达峰时间的小剂量对比剂和正式扫描的对比剂以相同注射流率(5 mL/s)分两段注射,中间注射相同流率生理盐水以抵消过渡延迟时间,注射方法是先注射2 s的对比剂,然后注射6 s生理盐水,再注射4 s对比剂,然后注射6 s生理盐水,过渡延迟时间设为10 s。由于两段对比剂的开始注射时间间隔是8 s,且注射流率相同,第1段对比剂达到设定阈值后8 s,第2段对比剂也将达到设定阈值,在此基础上再延迟2 s扫描,相当于第2段对比剂达到设定阈值后2 s开始扫描,此时第2段对比剂刚好完成一次肺循环,不会对肺静脉产生明显强化,而第1段对比剂达到设定阈值后10 s,大部分已经循环出肺静脉。此方法间接实现了将过渡延迟时间设定为2 s,解决了多数设备过渡延迟时间过长的问题,节省了对比剂用量,提高了检查的成功率。

    本研究中,试验组部分肺动脉血管CT值高于对照组,其他肺动脉血管CT值及锁骨下静脉CT值、肺静脉CT值、动静脉CT值差值均与对照组无差异,且两组图像在肺动脉图像质量和上腔静脉硬化伪影评分方面均无差异。本研究中,试验组升主动脉的CT值高于对照组,这与第1段对比剂流入胸主动脉导致胸主动脉部分强化有关,本研究中升主动脉CT值均<165 HU,不影响肺动脉的观察。同时本研究在扫描前嘱患者平静呼吸呼气末屏气,以减少因为过度吸气导致下腔静脉血大量回流入右心房,稀释右心腔对比剂产生肺动脉强化不佳的情况[16-18]

    综上,本研究在进行肺动脉CTA检查时使用两段式对比剂同速注射结合团注跟踪技术,可获得稳定的图像质量,其图像质量不低于传统的小剂量团注测试技术,且团注跟踪技术操作简单易行,受操作者个人影响较小。同时本研究通过在两段对比剂中间注射生理盐水抵消过渡延迟时间的方法,将过渡延迟时间设定为10 s,适用于大多数机器,值得在临床上推广。

    本研究的不足:①第一段对比剂在 10 s后大部分流入胸主动脉,导致胸主动脉强化,更有部分心功能不佳患者,第一段对比剂在10 s仍残留于肺静脉,影响肺动脉观察,这种情况要增加两段对比剂之间的生理盐水注射时间,同时增加过渡延迟时间,使第1段对比剂有充足的时间循环流出,而过渡延迟时间只需设定为两段对比剂开始注射间隔时间+2 s即可;②本研究第 2段对比剂用量为 20 mL,注射时间为4 s,要求设备扫描快,适用于将扫描时间控制在2~3 s的设备,如果设备扫描速度过慢,要适当增加第2段对比剂的用量;③本研究未将超重人群纳入,对于超重人群,20 mL对比剂是否适用需要进一步研究。

  • [1]

    SUNG H, FERLAY J, SIEGEL R, et al. Global cancer statistics 2020: Globocan estimates of incidence and mortality worldwide for 36 cancers in 185 countries[J]. Ca-A Cancer Journal for Clinicians, 2021, 71: 209-249. DOI: 10.3322/caac.21660.

    [2]

    VEITCH A M, UEDO N, YAO K S, et al. Optimizing early upper gastrointestinal cancer detection at endoscopy[J]. Nature Reviews Gastroenterology & Hepatology, 2015, 12: 660-667.

    [3]

    MENON S, TRUDGILL N. How commonly is upper gastrointestinal cancer missed at endoscopy? A meta-analysis[J]. Endoscopy International Open, 2014, 2(2): E46-E50. DOI: 10.1055/s-0034-1365524.

    [4]

    LI H, FENG L Q, BIAN Y Y, et al. Comparison of endoscopic submucosal dissection with surgical gastrectomy for early gastric cancer: An updated meta-analysis[J]. World Journal of Gastrointestinal Oncology, 2019, 11: 161-171. DOI: 10.4251/wjgo.v11.i2.161.

    [5]

    JÁCOME A A, COUTINHO A K, LIMA E M, et al. Personalized medicine in gastric cancer: Where are we and where are we going?[J]. World Journal of Gastroenterology, 2016, 22: 1160-1171. DOI: 10.3748/wjg.v22.i3.1160.

    [6]

    AERTS H J, VELAZQUEZ E R, LEIJENAAR R T, et al. Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach[J]. Nature Communications, 2014, 5: 4006. DOI: 10.1038/ncomms5006.

    [7]

    ASSOCIATION J G C. Japanese gastric cancer treatment guidelines 2018 (5th edition)[J]. Gastric Cancer, 2020, (S1): 1-21.

    [8]

    BENSON A B, VENOOK A P, AL-HAWARY M M, et al. Colon cancer, Version 2. 2021, NCCN clinical practice guidelines in oncology[J]. Journal of the National Comprehensive Cancer Network, 2021, 19: 329-359.

    [9]

    WANG Y, LIU W, YU Y, et al. CT radiomics nomogram for the preoperative prediction of lymph node metastasis in gastric cancer[J]. European Radiology, 2020, 30: 976-986. DOI: 10.1007/s00330-019-06398-z.

    [10]

    GAO X J, MA T T, CUI J L, et al. A CT-based radiomics model for prediction of lymph node metastasis in early stage gastric cancer[J]. Academic Radiology, 2021, 28: e155-e164. 5.

    [11]

    ZHANG A Q, ZHAO H P, LI F, et al. Computed tomography-based deep-learning prediction of lymph node metastasis risk in locally advanced gastric cancer[J]. Frontiers in Oncology, 2022, 12: 969707. DOI: 10.3389/fonc.2022.969707.

    [12]

    CHEN W J, WANG S W, DONG D, et al. Evaluation of lymph node metastasis in advanced gastric cancer using magnetic resonance imaging-based radiomics[J]. Frontiers in Oncology, 2019, 9: 1265. DOI: 10.3389/fonc.2019.01265.

    [13]

    BOKU N. HER2-positive gastric cancer[J]. Gastric Cancer, 2014, 17(1): 1-12. DOI: 10.1007/s10120-013-0252-z.

    [14]

    BANG Y J, Van CUTSEM E,, FEYEREISLOVA A, et al. Trastuzumab in combination with chemotherapy versus chemotherapy alone for treatment of HER2-positive advanced gastric or gastro-oesophageal junction cancer (ToGA): A phase 3, open-label, randomised controlled trial[J]. Lancet, 2010, 376: 687-697. DOI: 10.1016/S0140-6736(10)61121-X.

    [15]

    CHARALAMPAKIS N, ECONOMOPOULOU P, KOTSANTIS I, et al. Medical management of gastric cancer: A 2017 update[J]. Cancer Medicine, 2018, 7: 123-133. DOI: 10.1002/cam4.1274.

    [16]

    CUREA F G, HEBBAR M, ILIE S M, et al. Current targeted therapies in HER2-positive gastric adenocarcinoma[J]. Cancer Biotherapy and Radiopharmaceuticals, 2017, 32: 351-363. DOI: 10.1089/cbr.2017.2249.

    [17]

    LI Y X, CHENG Z X, GEVAERT O, et al. A CT-based radiomics nomogram for prediction of human epidermal growth factor receptor 2 status in patients with gastric cancer[J]. Chinese Journal of Cancer Research, 2020, 32: 62-71. DOI: 10.21147/j.issn.1000-9604.2020.01.08.

    [18]

    GUAN X, LU N, ZHANG J P. Evaluation of epidermal growth factor receptor 2 status in gastric cancer by CT-based deep learning radiomics nomogram[J]. Frontiers in Oncology, 2022, 12: 905203. DOI: 10.3389/fonc.2022.905203.

    [19]

    LIU Q F, LI J R, XIN B W, et al. Preoperative F-FDG PET/CT radiomics analysis for predicting HER2 expression and prognosis in gastric cancer[J]. Quantitative Imaging in Medicine and Surgery, 2023, 13: 1537-1549. DOI: 10.21037/qims-22-148.

    [20]

    COCCOLINI F, COTTE E, GLEHEN O, et al. Intraperitoneal chemotherapy in advanced gastric cancer: Meta-analysis of randomized trials[J]. European Society of Surgical Oncology, 2014, 40: 12-26. DOI: 10.1016/j.ejso.2013.10.019.

    [21]

    KIM S J, KIM H H, KIM Y H, et al. Peritoneal metastasis: Detection with 16- or 64-detector row CT in patients undergoing surgery for gastric cancer[J]. Radiology, 2009, 253: 407-415. DOI: 10.1148/radiol.2532082272.

    [22]

    MIRNIAHARIKANDEHEI S, HEIDARI M, DANALA G, et al. Applying a random projection algorithm to optimize machine learning model for predicting peritoneal metastasis in gastric cancer patients using CT images[J]. Computer Methods and Programs in Biomedicine, 2021, 200: 105937. DOI: 10.1016/j.cmpb.2021.105937.

    [23]

    DONG D, TANG L, LI Z Y, et al. Development and validation of an individualized nomogram to identify occult peritoneal metastasis in patients with advanced gastric cancer[J]. Annals of Oncology, 2019, 30: 431-438. DOI: 10.1093/annonc/mdz001.

    [24]

    CHEN Y, XI W Q, YAO W W, et al. Dual-energy computed tomography-based radiomics to predict peritoneal metastasis in gastric cancer[J]. Frontiers in Oncology, 2021, 11: 659981. DOI: 10.3389/fonc.2021.659981.

    [25]

    HUANG Z X, LIU D, CHEN X Z, et al. Deep convolutional neural network based on computed tomography images for the preoperative diagnosis of occult peritoneal metastasis in advanced gastric cancer[J]. Frontiers in Oncology, 2020, 10: 601869. DOI: 10.3389/fonc.2020.601869.

    [26]

    JIANG Y M, LIANG X K, WANG W, et al. Noninvasive prediction of occult peritoneal metastasis in gastric cancer using deep learning[J]. Jama Network Open, 2021, 4: e2032269. DOI: 10.1001/jamanetworkopen.2020.32269.

    [27]

    LIU D, ZHANG W H, HU F B, et al. A Bounding box-based radiomics model for detecting occult peritoneal metastasis in advanced gastric cancer: A multicenter study[J]. Frontiers in Oncology, 2021, 11: 777760. DOI: 10.3389/fonc.2021.777760.

    [28]

    LI W C, ZHANG L W, TIAN C, et al. Prognostic value of computed tomography radiomics features in patients with gastric cancer following curative resection[J]. European Radiology, 2019, 29: 3079-3089. DOI: 10.1007/s00330-018-5861-9.

    [29]

    JIN Y, XU Y L, LI Y Y, et al. Integrative radiogenomics approach for risk assessment of postoperative and adjuvant chemotherapy benefits for gastric cancer patients[J]. Frontiers in Oncology, 2021, 11: 755271. DOI: 10.3389/fonc.2021.755271.

    [30]

    SHIN J, LIM J S, HUH Y M, et al. A radiomics-based model for predicting prognosis of locally advanced gastric cancer in the preoperative setting[J]. Scientific Reports, 2021, 11: 1879. DOI: 10.1038/s41598-021-81408-z.

    [31]

    JIANG Y M, JIN C, YU H, et al. Development and validation of a deep learning CT signature to predict survival and chemotherapy benefit in gastric cancer: A multicenter, retrospective study[J]. Annals of Surgery, 2021, 274: e1153-e1161. DOI: 10.1097/SLA.0000000000003778.

    [32]

    ZHANG L W, DONG D, ZHONG L Z, et al. Multi-focus network to decode imaging phenotype for overall survival prediction of gastric cancer patients[J]. IEEE Journal of Biomedical and Health Informatics, 2021, 25: 3933-3942. DOI: 10.1109/JBHI.2021.3087634.

    [33]

    CHEN W J, GAO C, HU C, et al. Risk stratification and overall survival prediction in advanced gastric cancer patients based on whole-volume MRI radiomics[J]. Journal of Magnetic Resonance Imaging, 2023, 58: 1161-1174. DOI: 10.1002/jmri.28621.

    [34]

    ZHANG C D, NING F L, ZENG X T, et al. Lymphovascular invasion as a predictor for lymph node metastasis and a prognostic factor in gastric cancer patients under 70 years of age: A retrospective analysis[J]. International Journal of Surgery, 2018, 53: 214-220. DOI: 10.1016/j.ijsu.2018.03.073.

    [35]

    YARDIMCI A H, KOÇAK B, TURAN BEKTAŞ C, et al. Tubular gastric adenocarcinoma: Machine learning-based CT texture analysis for predicting lymphovascular and perineural invasion[J]. Diagnostic and Interventional Radiology, 2020, 26: 515-522. DOI: 10.5152/dir.2020.19507.

    [36]

    CHEN X F, YANG Z Q, YANG J D, et al. Radiomics analysis of contrast-enhanced CT predicts lymphovascular invasion and disease outcome in gastric cancer: A preliminary study[J]. Cancer Imaging, 2020, 20: 24. DOI: 10.1186/s40644-020-00302-5.

    [37]

    JIA H, LI R Z, LIU Y W, et al. Preoperative prediction of perineural invasion and prognosis in gastric cancer based on machine learning through a radiomics-clinicopathological nomogram[J]. Cancers (Basel), 2024, 16: undefined.

    [38]

    HE Y Y, YANG M, HOU R, et al. Preoperative prediction of perineural invasion and lymphovascular invasion with CT radiomics in gastric cancer[J]. European Journal of Radiology, 2024, 12: 100550.

    [39]

    BOSSUYT P K M, REITSMA J B, BRUNS D E, et al. STARD 2015: An updated list of essential items for reporting diagnostic accuracy studies[J]. British Medical Journal, 2015, 351: h5527.

    [40]

    ZHANG Y M, WENG Y, LUND J. Applications of explainable artificial intelligence in diagnosis and s-urgery[J]. Diagnostics (Basel), 2022, 12: 237. DOI: 10.3390/diagnostics12020237.

    [41]

    PANTELIS L, VASILIS P, SOTIRIS K. Explainable AI: A review of machine learning interpretability methods[J]. Entropy (Basel, Switzerland), 2020, 23(1): 18. DOI: 10.3390/e23010018.

  • 期刊类型引用(3)

    1. 杨文杰,梁烨,杨柯. 双流法肺动脉技术在肺动脉扫描中的应用评价. 影像诊断与介入放射学. 2024(04): 278-282 . 百度学术
    2. 胡嘉诚,刘云福,王新艳,王倩,马梓轩,张永县,李伟,刘荣,牛延涛. 对比剂分次团注联合能量成像获得CTU和CTA联合成像的应用研究. CT理论与应用研究. 2024(06): 692-700 . 本站查看
    3. 肖爱兰. 基于肺动脉CTA对肺栓塞检出流程优化的探讨. 现代医用影像学. 2024(09): 1644-1646+1656 . 百度学术

    其他类型引用(0)

计量
  • 文章访问数:  173
  • HTML全文浏览量:  33
  • PDF下载量:  31
  • 被引次数: 3
出版历程
  • 收稿日期:  2024-03-10
  • 修回日期:  2024-06-04
  • 录用日期:  2024-06-05
  • 网络出版日期:  2024-08-06
  • 刊出日期:  2025-07-04

目录

/

返回文章
返回
x 关闭 永久关闭