ISSN 1004-4140
CN 11-3017/P
SHI Liping, ZHANG Yaping, XIE Xueqian, JIANG Beibei, CHEN An. Quantitative Feature Change of Pulmonary Subsolid Nodule on CT Image to Determine Its Invasiveness[J]. CT Theory and Applications, 2019, 28(5): 541-548. DOI: 10.15953/j.1004-4140.2019.28.05.03
Citation: SHI Liping, ZHANG Yaping, XIE Xueqian, JIANG Beibei, CHEN An. Quantitative Feature Change of Pulmonary Subsolid Nodule on CT Image to Determine Its Invasiveness[J]. CT Theory and Applications, 2019, 28(5): 541-548. DOI: 10.15953/j.1004-4140.2019.28.05.03

Quantitative Feature Change of Pulmonary Subsolid Nodule on CT Image to Determine Its Invasiveness

More Information
  • Received Date: June 02, 2019
  • Available Online: November 07, 2021
  • Published Date: October 24, 2019
  • Aim: To quantitatively evaluate the changes of the non-solid components in pulmonary subsolid nodules (SSN) between baseline and follow-up CT scan in order to identity SSN with invasive manifestations, i.e., minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IAC). Materials and methods: Patients with baseline and follow-up CT scans, who had one or more SSNs and histological results, were retrospectively included. The measurement parameters were the maximum diameter of the whole SSN, the mean, the maximum and the minimum CT value, and the standard deviation of CT value of the non-solid component. Time dependent linear regression were used to evaluate the progression of nodule measurements from the baseline to follow-up scan. The diagnostic performance for SSN with invasive manifestations was evaluated by using the receiver operating characteristic curve and the area under the curve (AUC). Results: 71 patients (32 males and 39 females) with 78 SSNs were included. Nineteen SSNs were benign, ten adenocarcinoma in situ (AIS), 36 MIA and 13 IAC. The diameter of all SSNs positively correlated with time (all P<0.05). The standard deviation of CT values of the non-solid components with invasive manifestations positively correlated with time (P=0.37), but the other three CT values did not correlate with time (all P>0.05). In benign and AIS, all four CT value parameters had no correlation with time (all P>0.05). Annual changes of the standard deviation of CT value significantly determined invasive SSN (P=0.014). The sensitivity, specificity and AUC were 68.7%, 77.8% and 0.747, respectively. Conclusion: The diameter of benign, AIS, MIA and IAC increases during follow-up. The changes of the standard deviation of CT value may be used to differentiate and diagnose SSN with invasive manifestations (MIA and IAC).
  • Related Articles

    [1]FENG Weiyu, SHEN Xuzhang, TAN Jiawei, WANG Wentian. Influence of Ambient Noise Source Distributions on Cross-correlation Derived Seismic Waveforms and Dispersion Curve Retrieval[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.181
    [2]PAN Jishun, SUN Kaixuan, ZHANG Niu, LI Penghui. Non-SIRT Engineering Seismic Wave CT Technology[J]. CT Theory and Applications, 2020, 29(2): 119-127. DOI: 10.15953/j.1004-4140.2020.29.02.01
    [3]SI Youqiang, GUO Runhua, LI Mengru. Application of Optimal Noise Reduction Smooth Model Based on EMD and EEMD in Seismic Waves[J]. CT Theory and Applications, 2020, 29(1): 11-21. DOI: 10.15953/j.1004-4140.2020.29.01.02
    [4]GONG Ming-ping, ZHANG Jun-hua, LIU Wen-ge, LIU Yang, WU Xi-yuan. The Seismic Wave Numerical Simulation and Characteristics Analysis in Anisotropic Medium[J]. CT Theory and Applications, 2017, 26(6): 661-668. DOI: 10.15953/j.1004-4140.2017.26.06.01
    [5]PAN Ji-shun, SONG Chao-yang, LENG Yuan-bao, LI Yan-zhuo, WANG Xin-jian, ZHAO Xiang, GAO Dong-pan, LI Di. The Application of Seismic Wave CT to Qualities Detection of Concrete Cut-off Walls[J]. CT Theory and Applications, 2016, 25(3): 311-317. DOI: 10.15953/j.1004-4140.2016.25.03.07
    [6]TAN Jia-yan, LIU Guo-feng, GAO Jing-yu. High Order Finite Difference Forward Simulation of 2D and 3D Seismic Wave Field Based on GPU[J]. CT Theory and Applications, 2016, 25(1): 1-12. DOI: 10.15953/j.1004-4140.2016.25.01.01
    [7]LIU Rui-he, ZHOU Jian-ke, ZHOU Xue-feng, YIN Xing-yao, CAO Dan-ping. Finite Element Method with Arbitrary Quadrilateral Meshes for Numerical Modeling of Seismic Wave Based on Compact Storage[J]. CT Theory and Applications, 2015, 24(5): 667-680. DOI: 10.15953/j.1004-4140.2015.24.05.04
    [8]ZHENG Hai-liang, LI Xing-dong, WANG Zhe, WEI Cun-feng, CHANG Tong. A Practice on Parallel Reconstruction Algorithm of High Resolution Cone Beam Micro-CT Based on NVDIA GPU Graphic Card[J]. CT Theory and Applications, 2014, 23(5): 805-814.
    [9]FAN Hong-jun, FAN Ting-en, WANG Hui, GAO Yu-fei. Application of Seismic Waveform Classification Technique in the Study of Fluvial Reservoir[J]. CT Theory and Applications, 2014, 23(1): 71-80.
    [10]DAN Na-lin, ZHU De-bing, HUANG Xi-liu. The Test Method of Concrete Elements Integrity Using Seismic Image Profiling[J]. CT Theory and Applications, 2002, 11(2): 1-4.

Catalog

    Article views (669) PDF downloads (11) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return