QI Dong, QIAO Xiaochun, YAO Muzi, SHEN Yan, HU Shumin, SHI Biao. Comparison of Value of CTA and DSA in the Diagnosis of Spontaneous Isolated Superior Mesenteric Artery Dissection[J]. CT Theory and Applications, 2020, 29(5): 606-613. DOI: 10.15953/j.1004-4140.2020.29.05.12
Citation: QI Dong, QIAO Xiaochun, YAO Muzi, SHEN Yan, HU Shumin, SHI Biao. Comparison of Value of CTA and DSA in the Diagnosis of Spontaneous Isolated Superior Mesenteric Artery Dissection[J]. CT Theory and Applications, 2020, 29(5): 606-613. DOI: 10.15953/j.1004-4140.2020.29.05.12

Comparison of Value of CTA and DSA in the Diagnosis of Spontaneous Isolated Superior Mesenteric Artery Dissection

More Information
  • Received Date: February 14, 2020
  • Available Online: November 10, 2021
  • Objective:To investigate the diagnostic value of CTA and DSA in spontaneous isolated mesenteric artery dissection. Methods:The clinical data of 21 patients admitted to our hospital from January 2017 to December 2019 were retrospectively analyzed, and CTA and DSA were performed in all selected patients. Calculate the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CTA to SISMAD. To compare whether there are statistically significant differences in the accuracy of the two in the diagnosis of sismad. Using DSA as the gold standard, CTA performed a consistent Kappa test on the inspection results of SISMAD. Results:Of the 21 patients, 20 were diagnosed by CTA as SISMAD, one was superior mesenteric artery embolization, and the accuracy of CTA in the diagnosis of SISMAD was 95.23%. There was no significant difference in the accuracy of the two diagnoses(P>0.05). The sensitivity, specificity, positive predictive value and negative predictive value to type Ⅰ SISMAD were 75%, 84.61%, 75% and 84.61% respectively. The sensitivity, specificity, positive predictive value and negative predictive value of type Ⅱa SISMAD were 60%, 87.5%, 60%, 87.5%; The sensitivity, specificity, positive predictive value and negative predictive value of type Ⅱb SISMAD were 71.43%, 85.71%, 71.43%, 85.71%, 85.71%, respectively. The results of CTA examination of SISMAD were consistent with those of DSA(Kappa=0.738). Conclusion:CTA can diagnose spontaneous solitary mesenteric artery dissection quickly and accurately, and it has important guidance for the next treatment significance, which is worthy of clinical promotion and use.
  • Cited by

    Periodical cited type(9)

    1. 周雨晴,张佳佳,张广智,蔺营. 致密砂岩储层岩石物理建模及“甜点”预测. 地球物理学进展. 2025(01): 255-265 .
    2. 马宝,邵彪,赵昊洋,赵艺,赵东山,武周杰,孙朗秋. 页岩气储层岩石背散射图像中多种组分的人工智能识别. 科技创新与应用. 2025(17): 10-13+19 .
    3. 汪锐,李芳,刘仕友,孙万元,李松龄,黄晟. 岩石物理建模引导的低渗储层参数预测方法. 煤田地质与勘探. 2024(08): 187-197 .
    4. 钱佩璋,乔志伟,杜聪聪. 基于3MNet去噪网络的快速EPRI成像. CT理论与应用研究. 2023(01): 55-66 . 本站查看
    5. 王迪,张益明,张繁昌,丁继才,牛聪. 利用先验信息约束的深度学习方法定量预测致密砂岩“甜点”. 石油地球物理勘探. 2023(01): 65-74 .
    6. 张傲,李宗杰,刘军,闫星宇,李伟,顾汉明. 基于Yolox算法的碳酸盐岩储层溶洞“串珠状”异常反射智能检测. 石油地球物理勘探. 2023(03): 540-549 .
    7. 杜聪聪,乔志伟. 基于对抗式残差密集深度神经网络的CT稀疏重建. CT理论与应用研究. 2022(02): 163-172 . 本站查看
    8. 刘仕友,曲福良,周凡,邓利峰. 基于地震属性约简的深度学习储层物性参数预测:以莺歌海盆地乐东区为例. CT理论与应用研究. 2022(05): 577-586 . 本站查看
    9. 郑琳. 基于物联网边缘计算的数据挖掘方法研究. 无线互联科技. 2022(15): 140-142 .

    Other cited types(23)

Catalog

    Article views (453) PDF downloads (10) Cited by(32)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return