ISSN 1004-4140
CN 11-3017/P
DENG Xiaolin, XIE Hui, QU Yalin, WU Shaoquan, ZHOU Bangjian, YANG Zhengbin, FENG Lian, WANG Min. The Value of Optimal Monochromatic Spectral CT Imaging in Gastric Variceal Bleeding before Endoscopic Treatment[J]. CT Theory and Applications, 2021, 30(5): 603-609. DOI: 10.15953/j.1004-4140.2021.30.05.08
Citation: DENG Xiaolin, XIE Hui, QU Yalin, WU Shaoquan, ZHOU Bangjian, YANG Zhengbin, FENG Lian, WANG Min. The Value of Optimal Monochromatic Spectral CT Imaging in Gastric Variceal Bleeding before Endoscopic Treatment[J]. CT Theory and Applications, 2021, 30(5): 603-609. DOI: 10.15953/j.1004-4140.2021.30.05.08

The Value of Optimal Monochromatic Spectral CT Imaging in Gastric Variceal Bleeding before Endoscopic Treatment

More Information
  • Received Date: March 27, 2021
  • Available Online: September 22, 2021
  • Objective: We intend to evaluate the application value of optimal monochromatic spectral CT imaging performed on patients with gastric variceal bleeding before endoscopic treatment by way of observing the manifestation of portal vein, gastric varies gastro renal shunt etc. Methods: A total of 60 patients with gastric variceal bleeding admitted to our hospital from September 2016 to January 2021 were selected for spectral CT portal venography. By comparing the CT value of hepatic portal vein, the image noise (IN), the signal-to-noise ratio (SNR), contrast noise ratio (CNR) and subjective evaluation of the image quality among the 3 sets of images of optimal monochromatic energy group, 70keV group and mixed energy group (QC), we obtained the spectral CT portal venography with the best image quality for the imaging diagnosis. Results: The average CT values of hepatic portal vein of the 3 groups (the optimal monochromatic energy group, 70keV group and QC group) vein were 273.12±25.48, 168.70±20.16 and 164.92±20.74, respectively. the average IN value were 31.22±4.13, 17.72±3.09 and 24.25±2.98, respectively. The SNR were 8.95±1.80, 9.92±2.64 and 6.93±1.37, respectively. The CNR were 6.18±1.52, 4.82±1.71 and 3.22±0.99, respectively. While the subjective evaluation scores of image quality were 4.57±0.63, 3.10±0.98 and 2.47±0.93, respectively. All showed significant statistical difference except the average CT value of hepatic portal vein between the 70keV group and QC group. The CT portal venography with optimal monochromatic energy was the best, and it showed clear manifestation of gastric renal shunt, gastric varices, portal vein thrombosis, etc. Conclusion: The optimal monochromatic spectral CT imaging can optimize the image quality and it shows high application value when treated patients with gastric variceal bleeding before endoscopic surgery.
  • [1]
    中华医学会外科学分会脾及门静脉高压外科学组. 肝硬化门静脉高压症食管、胃底静脉曲张破裂出血诊治专家共识(2019版)[J]. 中华消化外科杂志, 2019, 18(12):1087-1093.

    DOI:10.3760/cma. j.issn.1673-9752.2019.12.001.
    [2]
    丁惠国, 张世斌, 李磊, 等. 肝硬化食管胃底静脉曲张的内镜诊断治疗——从指南到临床实践[J]. 临床肝胆病杂志, 2017, 33(3):454-457.

    DING H G, ZHANG S B, LI L, et al. Endoscopic diagnosis and treatment of esophageal and gastric varices in patients with liver cirrhosis:From guidelines to clinical practice[J]. Journal of Clinical Hepatology, 2017, 33(3):454-457. (in Chinese).
    [3]
    QIAO W, REN Y, BAI Y, et al. Cyanoacrylate injection versus band ligation in the endoscopic management of acute gastric variceal bleeding:Meta-Analysis of randomized, controlled studies based on the PRISMA statement[J]. Medicine, 2015, 94(41):e1725.
    [4]
    赵威, 徐浩, 崔艳峰, 等. 食管胃底静脉栓塞术中组织胶所致异位栓塞分析[J]. 医学影像学杂志, 2020, 30(10):1843-1846.

    ZHAO W, XU H, CUI Y F, et al. Clinical analysis of ectopic embolization induced by tissue adhesive during esophagogastric venous embolization[J]. Journal of Medical Imaging, 2020, 30(10):1843-1846. (in Chinese).
    [5]
    BURKE M P, O'DONNELL C, BABER Y. Death from pulmonary embolism of cyanoacrylate glue following gastric varix endoscopic injection[J]. Forensic Science, Medicine, and Pathology, 2017, 13(1):82-85.
    [6]
    游荣娇, 吴伟烽, 陈松发, 等. 组织胶注射治疗胃底静脉曲张致脑栓塞一例[J]. 中国现代神经疾病杂志, 2020, 20(3):248-251.

    YOU R J, WU W F, CHEN S F, et al. Cerebral embolism caused by tissue adhesive injection for varices of gastric fundus:one case report[J]. Chinese Journak of Contemporary Neurology and Neurosurggery, 2020, 20(3):248-251. (in Chinese).
    [7]
    梅雪灿, 马维娟, 孔德润. 胃底静脉曲张组织胶治疗并发脑动脉空气栓塞一例[J]. 中华消化内镜杂志, 2020, 37(1):61-62.
    [8]
    柳维娜, 董健, 王仁贵. 宽体探测器能谱CT最佳单能量成像在肝门静脉与肝静脉成像中的应用价值研究[J]. 中国医学装备, 2020, 17(4):83-86.

    DOI:10.3969/J.ISSN.1672-8270.2020.04.020. LIU W N, DONG J, WANG R G. Study on the application of optimally single energy imaging of energy spectrum CT with wide detector in imaging of hepatic portal vein and hepatic vein[J]. China Medical Equipment, 2020, 17(4):83-86. DOI:10.3969/J.ISSN.1672-8270.2020.04.020. (in Chinese).
    [9]
    HAN D, CHEN X, LEI Y, et al. Iodine load reduction in dual-energy spectral CT portal venography with low energy images combined with adaptive statistical iterative reconstruction[J]. The British Journal of Radiology, 2019, 92(1100):20180414.
    [10]
    QI X, LI Z, HUANG J, et al. Virtual portal pressure gradient from anatomic CT angiography[J]. Gut, 2015, 64(6):1004-1005.
    [11]
    刘伟, 刘盛楠. 门静脉造影+多层螺旋CT用于肝硬化食管胃底静脉曲张破裂出血患者围术期的意义[J]. 肝脏, 2020, 25(11):1185-1187.

    DOI:10.14000/j.cnki.issn.1008-1704.2020.11.016. LIU W, LIU S N. Application value of perioperative multi-slice spiral CT portal venography in cirrhotic patients with esophagogastric variceal bleeding[J]. Chinese Hepatology, 2020, 25(11):1185-1187. DOI:10.14000/j.cnki.issn.1008-1704.2020.11.016. (in Chinese).
    [12]
    王伟新, 张秋奂, 郭鹏德, 等. 能谱CT单能量结合ASiR技术对腹部静脉成像质量的优化研究[J]. CT理论与应用研究, 2019, 28(1):61-72.

    DOI:10.15953/j.1004-4140.2019.28.01.07. WANG W X, ZHANG Q H, GUO P D, et al. The evaluation of imaging quality of abdominal vein by combining spectral CT optimal monotromatic imging and ASiR technique[J]. CT Theory and Applications, 2019, 28(1):61-72. DOI:10.15953/j.1004-4140.2019.28.01.07. (in Chinese).
    [13]
    WANG W, HUANG J, WANG A, et al. Dual-energy spectral computed tomography with adaptive statistical iterative reconstruction for improving image quality of portal venography[J]. Journal of Computer Assisted Tomography, 2018, 42(6):954-958.
    [14]
    MA C L, CHEN X X, LEI Y X, et al. Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography:In comparison with standard 120-kVp imaging protocol[J]. The British Journal of Radiology, 2016, 89(1062):20151022.
    [15]
    邓小林, 谢惠, 屈亚林, 等. 能谱CT最佳单能量技术优化头颈部CTA图像质量的研究[J]. CT理论与应用研究, 2018, 27(6):719-726.

    DOI:10.15953/j.1004-4140.2018.27.06.05. DENG X L, XIE H, QU Y L, et al. Spectral CT with optimal monochromatic energy to improve CTA image quality of head and neck[J]. CT Theory and Applications, 2018, 27(6):719-726. DOI:10.15953/j.1004-4140.2018.27.06.05. (in Chinese).
    [16]
    ZHAO L, WINKLHOFER S, JIANG R, et al. Dual energy CT (DECT) monochromatic imaging:Added value of adaptive statistical iterative reconstructions (ASIR) in portal venography[J]. PloS One, 2016, 11(6):e0156830.
    [17]
    宋明全, 孙学国, 李倩, 等. CT门静脉成像指导内镜治疗胃底静脉曲张疗效[J]. 世界华人消化杂志, 2021, 29(1):41-47.

    DOI:10.11569/wcjd.v29.i1.41. SONG M Q, SUN X G, LI Q, et al. CT portography guided endoscopic injection of cyanoacrylate into gastric varices[J]. World Chinese Journal of Digestology, 2021, 29(1):41-47. DOI:10. 11569/wcjd.v29.i1.41. (in Chinese).
    [18]
    李会贤, 孔德润. 胃肾及脾肾分流道对胃底曲张静脉内镜治疗的影响[J]. 世界华人消化杂志, 2017, 25(20):1805-1810.

    DOI:10.11569/wcjd.v25.i20.1805. LI H X, KONG D R. Effect of gastrorenal shunt and splenorenal shunt on endoscopic treatment of gastric varices[J]. World Chinese Journal of Digestology, 2017, 25(20):1805-1810. DOI:10.11569/wcjd.v25.i20.1805. (in Chinese).
  • Related Articles

    [1]YOU Long-ting, SONG Jian-guo, YU Hui-zhen, WANG Yue-lei. Analysis of the Influence Factors on the Time-Frequency Spectrum Obtained by Synchrosqueezing Wavelet Transform based on Reconstruction of Analytic Signal[J]. CT Theory and Applications, 2017, 26(3): 267-278. DOI: 10.15953/j.1004-4140.2017.26.03.02
    [2]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [3]LIU Hai-yan, TIAN Gang, SHI Zhan-jie. The Comparison of Time-frequency Analysis Methods and Their Applications[J]. CT Theory and Applications, 2015, 24(2): 199-208. DOI: 10.15953/j.1004-4140.2015.24.02.06
    [4]FAN Hua, ZHAO Guo-chun, HAN Yan-jie, LIU Ming-jun, LI Xiao-qin, SUN Yong-jun. Image Fusion in Combination of the Improved IHS Transform and Wavelet Transform[J]. CT Theory and Applications, 2014, 23(5): 761-770.
    [5]FENG Xia, SHI Chao, DING Wen-bo, FENG Yan, HAO Zhen-ping. The Complication of Spectral Analysis Based on Fourier Transform in the Tire X-ray Detection[J]. CT Theory and Applications, 2014, 23(3): 453-458.
    [6]ZHANG Xi-le, HUANG Jing, LIU Nan, LU Li-jun, MA Jian-hua, CHEN Wu-fan. Wavelet-Transform Based Low-Dose CT Projection Filtering[J]. CT Theory and Applications, 2011, 20(2): 163-171.
    [7]DONG Fang, HU Liang, LI Bo-lin, LI Ming, CHEN Hao, WANG Yuan, ZHANG Cheng-xin, XU Zhou. Contour Data Denoise Based on Inter-Scale Correlations of Contourlet Transform[J]. CT Theory and Applications, 2008, 17(4): 62-66.
    [8]SUN Cun-jie, ZHANG Hong. The Study on Methods of CT Image Enhancement[J]. CT Theory and Applications, 2005, 14(4): 17-20.
    [9]HAN Yu-sheng, LU Wei, LIU Han, LI Cong-li. Enhancement processing on Security Inspection Image Based on Db Wavelet Transform and median Filtering[J]. CT Theory and Applications, 2005, 14(1): 7-10.
    [10]ZHONG Shi-hang. Examining Quality of Retaining Wall Made of Mortar and Stones by Means of Comparing Spectrum of Elastic Reflection Wave Frequncy[J]. CT Theory and Applications, 2002, 11(1): 1-5.
  • Cited by

    Periodical cited type(1)

    1. 张明霞,李玲,高兰,王玉华,孙莹,孙磊,霍萌,张春燕,王仁贵. 不同预后的抗MDA5抗体阳性IIMs患者肺部HRCT定量指标与临床研究. CT理论与应用研究. 2024(03): 351-358 . 本站查看

    Other cited types(0)

Catalog

    Article views (193) PDF downloads (22) Cited by(1)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return