The Value Evaluation of Multi-slice Spiral CT in the Main Pulmonary Artery Hemodynamics of the Different Stages of Patients with Pneumoconiosis

More Information
  • Received Date: January 19, 2015
  • Available Online: December 05, 2022
  • Objective: To investigate the value evaluation of Multi-slice spiral CT in the main pulmonary artery hemodynamics of the Different stages of patients with Pneumoconiosis. Methods: 100 cases of pneumoconiosis patients in our hospital were selected as the study group, and 30 cases of healthy people were selected as the control group. All patients were detected with X-ray chest films and Multi- spiral CT, Compared the main pulmonary artery diameter, mean velocity, peak flow in unit time, flow and other parameters of different stages of pneumoconiosis patients and healthy people. Results: The pulmonary artery mean velocity, peak flow and unit time flow of the healthy population was significantly higher than that of patients with pneumoconiosis,and pulmonary artery mean velocity, peak flow and unit time flow and pneumoconiosis stage was inversely proportional, with statistically significant difference (<i<P</i<<0.05). The aortic diameter of the healthy group was significantly lower than the pneumoconiosis patients and the arterial diameter of the patients with pneumoconiosis was proportional to Pneumoconiosis stage, with significant difference (<i<P</i<<0.05). The positive detection rate of Multi-slice was significantly higher than that of X-ray film, with significant difference (<i<P</i<<0.05). Conclusion: Multi-slice spiral CT scan can effectively detect the main pulmonary artery hemodynamics changes of the different stages of pneumoconiosis patients, can provide effective reference for pneumoconiosis stage.
  • Related Articles

    [1]JIANG Yang, TANG Wentao, HU Ran, HU Qinqin, LI Gangjing, ZHANG Hao, YU Ting, ZHANG Dechuan. Impact of Individual Body Shape Factors and Tissue Contents on the Water Equivalent Diameter of Size-Specific Dose Estimations in Adult Chest CT[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.272
    [2]LEI Lixing, HUANG Xiaohua, LIU Nian, TANG Lingling, MA Linjun. Analysis of Accuracy, Image Quality, and Effective Dose of Coronary CT Angiography Using Dual-Source CT with Turbo-Flash Mode to Evaluate Coronary Artery Stenosis[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.350
    [3]LIU Yuhang, LI Wei, NIU Yantao, ZHANG Yongxian, WANG Yuchen, YANG Bingbing, LIU dandan. Low-Dose Study on Coronary Artery Calcium Score Scanning Using the SEMI Mode of the Intelligent Optimal Tube Voltage Selection Technique in Combination with an Iterative Algorithm[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.317
    [4]Ma Wentao, Zhang Yongxian, Guo Senlin, Liu Yunfu, Kang Tianliang. Study on the Impact of Different Tube Voltages Combined with Organ Dose Modulation on Cerebral Perfusion Image Quality and Ocular Lens Radiation Dose[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.337
    [5]FENG Mengya, LI Bing, WU Min, HUA Ting, TANG Guangyu. Application of New Iterative Reconstruction Algorithm Based on Artificial Intelligence and Low Tube Voltage in Reducing the Radiation Dose of Coronary CTA in Obese Patients[J]. CT Theory and Applications, 2023, 32(6): 777-782. DOI: 10.15953/j.ctta.2022.148
    [6]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [7]LIANG Hong-sheng, CHEN Jin-jun, CHEN Xiao-yu, LIANG Yu-hao, OU Jian-yang, MA Guan-hua. Dose 4D CARE Technology Combined with Low kV and Low Dose Contrast Agent in MSCT Head and Neck Vascular Imaging Applications[J]. CT Theory and Applications, 2017, 26(5): 605-612. DOI: 10.15953/j.1004-4140.2017.26.05.10
    [8]TIAN Zhi-nan, LONG Shi-liang, ZHAO Yue, TAN Hong-wen. Feasibility of 80 kVp Ultra-low Dose Scan Protocol in Prospective Coronary CT Angiography[J]. CT Theory and Applications, 2017, 26(1): 99-106. DOI: 10.15953/j.1004-4140.2017.26.01.13
    [9]BAO Li-wei, WANG Ze-feng, SUN Zhen-ting, MENG Ling-xin, ZHAO Lei. Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA[J]. CT Theory and Applications, 2015, 24(1): 87-94. DOI: 10.15953/j.1004-4140.2015.24.01.10
    [10]LI Ruo-mei, WANG Si-wei, JIN Dan-dan. Low-dose CT Coronary Angiography with Status Quo of Tube Current and Voltage Parameters Optimization[J]. CT Theory and Applications, 2012, 21(3): 515-520.
  • Cited by

    Periodical cited type(2)

    1. 涂立冬,李雅萍. 岩土勘查技术在盐矿绿色矿山建设中的应用初探. 盐科学与化工. 2025(04): 9-12 .
    2. 杨兆林,潘懿,白旭晨,刘禄平. 露天铁矿采空区隐蔽致灾普查与防治措施应用研究. 矿业研究与开发. 2024(09): 74-81 .

    Other cited types(2)

Catalog

    Article views (648) PDF downloads (2) Cited by(4)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return