  • Object: To investigate the statistic relationship between 5 clock positions of CTDI100 and stabilization of radiation. Method: Radiation meter and phantom are used to 12 time repeating tests on the radiation dose of a spiral CT at 5 Clock positions and then one-way ANOVA method is used to character the their difference significance of those 5 clock positions. Result: The relevant standard difference of measurements at 5 test clock positions are 0.33%(center), 0.73%(3 clock), 0.32%(6 clock), 1.00%(9 clock), 0.32%(12 clock) respectively; meanwhile the average of measurements at 3 clock is much close to that at 9 clock and no significant difference is found in one-way ANOVA test;Moreover the relative deviation between mean value of 12 Clock plus 6 Clock and 3 Clock is 0.5%. Conclusion: The tested spiral CT shows good radiation stability and 3 Clock position have equal effect with 9 clock's in CTDI100 measuring, moreover, peripheral CTDI of that can be simplified except for non-acceptance test or operational condition test.
  • Related Articles

    [1]YU Ming, HU Jiayuan, SONG Yan, LI Saying. Analysis of Spiral CT Phenotypes and Features of Primary Intestinal Lymphoma[J]. CT Theory and Applications, 2022, 31(4): 449-458. DOI: 10.15953/j.ctta.2022.090
    [2]SU Da-jun, ZHA Yun-fei. Application of ASIR Techniques in Hip with Low Tube Current 64 Row CT[J]. CT Theory and Applications, 2014, 23(6): 1011-1017.
    [3]WANG Guo-shi, WEI Ming-gui, LI Shao-wei, SHA Yan-zhi. Comparison between Two Materials of Bone Graft in Guided Bone Regeneration by CT Image Analysis[J]. CT Theory and Applications, 2014, 23(5): 843-850.
    [4]YANG Xiao-sheng, CHEN Qin, CHEN Xi-feng. Spiral CT Diagnosis of Acute Pancreatitis Classification Method and its Clinical Significance[J]. CT Theory and Applications, 2012, 21(4): 735-740.
    [5]MAO Guo-min, JIANG Zhi-rui. An Analysis of the Development and Present Situation of "CT Theory and Applications"[J]. CT Theory and Applications, 2011, 20(4): 573-582.
    [6]CHEN Xing-ming, LIANG Zhen-hua. The Diagnostic Value of 16-Slice Spiral CT Reconstruction in Talus Fractures[J]. CT Theory and Applications, 2010, 19(1): 87-92.
    [7]LI Jiang-shan, LI Shao-dong, CHENG Guang-jun, XU Kai. Application of Multi-slice Spiral CT in the Diagnosis of Moyamoya Disease[J]. CT Theory and Applications, 2005, 14(4): 33-37.
    [8]PENG Lei, XU Chun-lin, WEI Li-li. Spiral CT 3D Reconstructions for Pelvic Application in Bone Fracture[J]. CT Theory and Applications, 2002, 11(3): 39-41.
    [9]HUANG Li-ling, WANG Xu-wen. Applications of More-phase Spiral CT in Small Hepatic Hemangioma[J]. CT Theory and Applications, 2002, 11(3): 29-30.
    [10]Guo Sujin, Huan Yi. Spiral CT: Renal Disease Applications[J]. CT Theory and Applications, 2000, 9(1): 26-28.

Catalog

    Article views (789) PDF downloads (2) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return