ISSN 1004-4140
CN 11-3017/P
GUO Zhi-min, NI Pei-jun, CAO Yu-ling, QI Zi-cheng, QIAO Ri-dong. Analysis and Evaluation of Two Assessment Techniques for ICT Scanner Spatial Resolution Measurement[J]. CT Theory and Applications, 2015, 24(3): 393-399. DOI: 10.15953/j.1004-4140.2015.24.03.08
Citation: GUO Zhi-min, NI Pei-jun, CAO Yu-ling, QI Zi-cheng, QIAO Ri-dong. Analysis and Evaluation of Two Assessment Techniques for ICT Scanner Spatial Resolution Measurement[J]. CT Theory and Applications, 2015, 24(3): 393-399. DOI: 10.15953/j.1004-4140.2015.24.03.08

Analysis and Evaluation of Two Assessment Techniques for ICT Scanner Spatial Resolution Measurement

More Information
  • Received Date: November 23, 2014
  • Available Online: December 08, 2022
  • Spatial resolution is the two most important parameters of CT image quality, and the test work of this parameter is main part of CT scanner's quality assurance. This paper represents two methods, which were dedicated for the assessment of spatial resolution in CT system, and analysis spatial resolution of CT system by using software tools. The comparative study of the two methods was carried out in 3 ICT systems under the same experiment condition. We found that the test result of disc phantom method is significantly higher than the result of practical-MTF method, and then the relationship between the test results of the two methods was discussed.
  • Related Articles

    [1]DUAN Chengxiang, LIANG Yuan, FAN Xiaohui, ZHANG Fanchang, WU Jun. Research on High Resolution Seismic Date Processing Method Based on Adaptive VMD[J]. CT Theory and Applications, 2022, 31(2): 135-148. DOI: 10.15953/j.1004-4140.2022.31.02.01
    [2]YU Qian-qian, LI Zhen-chun, ZHANG Min, ZHANG Kai, YU Zhen-nan, ZHANG Xin, PAN Dong. The Study of Seismic Attenuation Tomography Inversion Based on Spectrum Ratio Method[J]. CT Theory and Applications, 2017, 26(5): 533-541. DOI: 10.15953/j.1004-4140.2017.26.05.01
    [3]ZHANG Wei-guo, CAO Yu-ling, GUO Zhi-min, NI Pei-jun, ZUO Xin, WANG Xiao-yan, HAO Li-ping. Explore of Different Line-pairs Test Spatial Resolution CT[J]. CT Theory and Applications, 2014, 23(5): 815-820.
    [4]GAO Jie, TAN Mao-jin, ZHONG Guang-hai, LIU Huan-li. Resolution Matching Method of High Induction Logging and Applications[J]. CT Theory and Applications, 2009, 18(2): 41-49.
    [5]QUE Jie-min, WANG Yan-fang, LIU Li. Experimental Research on Improving the Spatial Resolution by Using the Method of Pixel Offset Scanning[J]. CT Theory and Applications, 2009, 18(1): 83-87.
    [6]LI Jing-hui, LI Qing-lin, YIN Jian-wu, FANG Qing-yin, LI Jun. The Application of Resistivity Tomography Method in Cave Exploration[J]. CT Theory and Applications, 2007, 16(4): 22-30.
    [7]LI Zheng-rong, LIU Xiao-ping, LI Zi-yuan, DING Hou-ben. Research of the Method for Multi-threshold Value in Image Segmentation[J]. CT Theory and Applications, 2006, 15(4): 13-17.
    [8]ZHAN Jie, YU Xiao-e. Practice and Study on Automatic Measurement of CT Spatial Resolution[J]. CT Theory and Applications, 2006, 15(2): 43-46.
    [9]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
    [10]CHEN Wei-chang, CHEN Zhi-hua, ZHAO Tian-de, WANG Zi-qiang. Improvement of CT Contrast (Density) Resolution By Dual Photons Absorption Method[J]. CT Theory and Applications, 2002, 11(4): 5-8.

Catalog

    Article views (1024) PDF downloads (41) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return