CAO Hua, YANG Ming, CHEN Xin-jian, ZOU Jia-ni, WU Qian. Principles and Comparative Study by 320/64 Slice CTA and DSA in Diagnosis of Intracranial Aneurysms[J]. CT Theory and Applications, 2015, 24(4): 495-502. DOI: 10.15953/j.1004-4140.2015.24.04.03
Citation: CAO Hua, YANG Ming, CHEN Xin-jian, ZOU Jia-ni, WU Qian. Principles and Comparative Study by 320/64 Slice CTA and DSA in Diagnosis of Intracranial Aneurysms[J]. CT Theory and Applications, 2015, 24(4): 495-502. DOI: 10.15953/j.1004-4140.2015.24.04.03

Principles and Comparative Study by 320/64 Slice CTA and DSA in Diagnosis of Intracranial Aneurysms

More Information
  • Received Date: May 04, 2015
  • Available Online: December 08, 2022
  • Objective: Comparative study the principles and applications of 320 Slice, 64 Slice CTA and rotation 3D DSA in diagnosis of intracranial aneurysms in order to choose the most appropriate inspection ways. Methods: The 86 patients who were highly suspected with intracranial aneurysms were examined by 320 slice CTA, 64 slice spiral CTA and had 3D DSA inspection at the same time. To conduct a comparative study of the characteristics of CTA and 3D DSA image. Results: 86 cases had been confirmed by operation and interventional procedures.92 cases were detected by 320 Slice CTA, 90 cases were detected by 64 slice CTA and 96 cases were detected by 3D DSA respectively, There was no significant difference between 320 slice, 64 slice CTA and 3D DSA(<i<P</i<<0.05). Conclusions: 320 Slice CTA, 64 Slice CTA and 3D DSA examination has their own advantage in the diagnosis of intracranial aneurysms. The 320 Slice CTA is a good method to diagnose aneurysms and is of the advantages including rapidness, noninvasive imaging and high accuracy. CTA are assistant tools for DSA in inspecting intracranial aneurysms. And the re-examination after the surgery still should be the first choice for screening in the patient with aneurysm. And 320 slice CTA is obviously superior to 64 slice CTA, 320-Slice CTA still cannot replace DSA and 3D RA because it may miss very small aneurysm.
  • Cited by

    Periodical cited type(4)

    1. 吴万锋,王云云,杨道坤. 新型冠状病毒感染应用不同抗病毒药物治疗后的疗效分析. 临床荟萃. 2025(02): 147-152 .
    2. 曹宽,武雨,冀若瑶,赵亚玲. SARS-CoV-2感染患者发生肺部炎症的影响因素分析. 延安大学学报(医学科学版). 2024(01): 20-23+64 .
    3. 张小雪,杨明浩,王红,金朝,徐艳,李宝辉,张立辉,蒋科,王海霞,杨景慧,李毅峰,郑媛憬,卫晓阳. 飞行学员新型冠状病毒感染康复后载人离心机训练情况调研. 中华航空航天医学杂志. 2024(02): 128-131 .
    4. 倪崇俊,宁卫卫,沈笑春. 喉咽清颗粒与阿比多尔及干扰素联合治疗轻型/普通型新型冠状病毒感染的疗效与安全性. 临床合理用药. 2024(27): 50-53 .

    Other cited types(1)

Catalog

    Article views (764) PDF downloads (6) Cited by(5)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return