ISSN 1004-4140
CN 11-3017/P
LIU Qun, LIU Li, QIAO Hong-yan, FU Tian-peng, JIANG Jian-wei, FAN Chang-yan. Analysis of Brain Damage and Cerebral Vasospasm in Patients with SAH by 256 Slice Spiral CT CTA[J]. CT Theory and Applications, 2015, 24(6): 857-863. DOI: 10.15953/j.1004-4140.2015.24.06.12
Citation: LIU Qun, LIU Li, QIAO Hong-yan, FU Tian-peng, JIANG Jian-wei, FAN Chang-yan. Analysis of Brain Damage and Cerebral Vasospasm in Patients with SAH by 256 Slice Spiral CT CTA[J]. CT Theory and Applications, 2015, 24(6): 857-863. DOI: 10.15953/j.1004-4140.2015.24.06.12

Analysis of Brain Damage and Cerebral Vasospasm in Patients with SAH by 256 Slice Spiral CT CTA

More Information
  • Received Date: October 19, 2015
  • Available Online: December 08, 2022
  • Objective: To study the diagnostic effect of SAH(CT) in the diagnosis of primary subarachnoid hemorrhage(CTA) and to evaluate the effect of serum S-100 protein on brain damage and cerebral vasospasm in SAH patients. Methods: patients with CTA from 2013 April 2014 march in our hospital, according to Glasgow Coma Scale(GCS) coma score and hunt Hess grade divided into different groups, they were detected by 256 slice spiral CT head CTA examination and serum S-100 B protein levels. Results: In 77 patients with SAH by CT sports a CTA examination 59 aneurysm. GCS score 3~8 points of patients admitted to hospital after 1 d, 7 d S-100 B protein levels were(1.94 ±0.31) μg/L respectively,(1.93 ±0.28) μg/L was significantly higher than patients with GCS score 9~12 points 1d, d after admission S-100 B protein levels(1.13 ±0.21) of μg/L,(1.09 ±0.19) μg/L and GCS score 13~15 points, 1 d, 7 d after admission in patients with S-100 B protein levels(0.54 ±0.09) of μg/L, μg/L(0.52 ±0.06), statistically significant difference(P<0.05). Hunt and Hess grade III patients admitted to hospital after 1 d, 7 d S-100 B protein levels were(0.68 ±0.12) μg/L,(0.64 ±0.11) of μg/L significantly lower than Hunt-Hess level III patients admitted to hospital after 1 d, 7 d S~100B protein levels(1.15 ±0.18) μg/L,(0.98 ±0.12) μg/L and Hunt-Hess level IV patients admitted to hospital after 1 d, 7 d S~100B protein levels(2.08 ±0.25) of μg/L,(1.99 ±0.23) μg/L, statistically significant difference(P<0.05). Conclusion: 256 slice spiral CT head and neck CTA scan can be effective response to the peripheral vascular three-dimensional structure of patients with SAH, the SAH patients with S-100 B protein level detection, can effectively evaluate the degree of brain damage and vascular spasm in SAH patients.
  • Related Articles

    [1]LI Wen, ZHANG Zhiwei, ZUO Ziyu, WAN Chengxin, TANG Yu, YANG Yajing. The Value of Virtual Monoenergetic Computed Tomography Angiography with Dual-layer Detector Spectral Computed Tomography for Imaging Cerebral Vessels[J]. CT Theory and Applications, 2024, 33(6): 669-675. DOI: 10.15953/j.ctta.2024.074
    [2]ZHANG Jing, CHEN Jun, LI Jun, SHAO Xianmin, WANG Wenxia. Imaging Value of Contrast-enhanced Susceptibility-weighted Imaging for Cerebral Cavernous Malformations[J]. CT Theory and Applications, 2021, 30(3): 371-378. DOI: 10.15953/j.1004-4140.2021.30.03.11
    [3]FAN Li, HUANG Jingbo. Correlation between the Degree of Middle Cerebral Artery Stenosis and CT Perfusion Parameters in the Early Stage of Cerebral Infarction[J]. CT Theory and Applications, 2020, 29(2): 219-227. DOI: 10.15953/j.1004-4140.2020.29.02.13
    [4]SUN Ying-ying, DING Zhang-qing, LUO Hui, DAI Lan-lan, WANG Wen-sheng, DING Ai-lan, WANG Xue-lu. Imaging Manifestation of Cerebral Cortical Laminar Necrosis[J]. CT Theory and Applications, 2017, 26(2): 211-218. DOI: 10.15953/j.1004-4140.2017.26.02.10
    [5]LI Yang, CHA Yun-fei. CTA Evaluation of Carotid Plaque Composition and Volume Correlation with Cerebral Vascular Symptoms[J]. CT Theory and Applications, 2016, 25(5): 601-607. DOI: 10.15953/j.1004-4140.2016.25.05.13
    [6]ZHANG Yi-zhao, HU Hai-jing, XU Xin-chao. Value of MSCTA in Diagnosing Non-Proliferative Cerebral Vascular Malformation[J]. CT Theory and Applications, 2013, 22(3): 485-492.
    [7]LIU Chao, ZOU Jian-hua, CHEN Lun-gang, CHEN Yi-jia. The Value of 64-slice CTA in the Etiological Diagnosis of Spontaneous Subarachnoid Hemorrhage[J]. CT Theory and Applications, 2010, 19(4): 71-78.
    [8]MING Jian-zhong, ZENG Zhi-bin, ZHONG Wen-xin, PENG Ke-wen, SHEN Bi-xian. The Application of Bone Subtraction 3D-CTA for the Evaluation of Cerebral Vascular Disease[J]. CT Theory and Applications, 2010, 19(1): 82-86.
    [9]ZHU Ting-ting, GAN Wan-chong. Contrast Quantity and Injection Velocity in Cerebral Angiography with 64 Multi-Detector CT[J]. CT Theory and Applications, 2009, 18(4): 109-114.
    [10]Pu Zhaoxia, Li Xiuhua. The CT Diagnosis of Cerebral Tuberculosis In 10 Cases[J]. CT Theory and Applications, 2000, 9(4): 32-34.

Catalog

    Article views (677) PDF downloads (2) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return