ISSN 1004-4140
CN 11-3017/P
Volume 24 Issue 6
Dec.  2015
Turn off MathJax
Article Contents
LIU Qun, LIU Li, QIAO Hong-yan, FU Tian-peng, JIANG Jian-wei, FAN Chang-yan. Analysis of Brain Damage and Cerebral Vasospasm in Patients with SAH by 256 Slice Spiral CT CTA[J]. CT Theory and Applications, 2015, 24(6): 857-863. DOI: 10.15953/j.1004-4140.2015.24.06.12
Citation: LIU Qun, LIU Li, QIAO Hong-yan, FU Tian-peng, JIANG Jian-wei, FAN Chang-yan. Analysis of Brain Damage and Cerebral Vasospasm in Patients with SAH by 256 Slice Spiral CT CTA[J]. CT Theory and Applications, 2015, 24(6): 857-863. DOI: 10.15953/j.1004-4140.2015.24.06.12

Analysis of Brain Damage and Cerebral Vasospasm in Patients with SAH by 256 Slice Spiral CT CTA

More Information
  • Received Date: October 19, 2015
  • Available Online: December 08, 2022
  • Objective: To study the diagnostic effect of SAH(CT) in the diagnosis of primary subarachnoid hemorrhage(CTA) and to evaluate the effect of serum S-100 protein on brain damage and cerebral vasospasm in SAH patients. Methods: patients with CTA from 2013 April 2014 march in our hospital, according to Glasgow Coma Scale(GCS) coma score and hunt Hess grade divided into different groups, they were detected by 256 slice spiral CT head CTA examination and serum S-100 B protein levels. Results: In 77 patients with SAH by CT sports a CTA examination 59 aneurysm. GCS score 3~8 points of patients admitted to hospital after 1 d, 7 d S-100 B protein levels were(1.94 ±0.31) μg/L respectively,(1.93 ±0.28) μg/L was significantly higher than patients with GCS score 9~12 points 1d, d after admission S-100 B protein levels(1.13 ±0.21) of μg/L,(1.09 ±0.19) μg/L and GCS score 13~15 points, 1 d, 7 d after admission in patients with S-100 B protein levels(0.54 ±0.09) of μg/L, μg/L(0.52 ±0.06), statistically significant difference(P<0.05). Hunt and Hess grade III patients admitted to hospital after 1 d, 7 d S-100 B protein levels were(0.68 ±0.12) μg/L,(0.64 ±0.11) of μg/L significantly lower than Hunt-Hess level III patients admitted to hospital after 1 d, 7 d S~100B protein levels(1.15 ±0.18) μg/L,(0.98 ±0.12) μg/L and Hunt-Hess level IV patients admitted to hospital after 1 d, 7 d S~100B protein levels(2.08 ±0.25) of μg/L,(1.99 ±0.23) μg/L, statistically significant difference(P<0.05). Conclusion: 256 slice spiral CT head and neck CTA scan can be effective response to the peripheral vascular three-dimensional structure of patients with SAH, the SAH patients with S-100 B protein level detection, can effectively evaluate the degree of brain damage and vascular spasm in SAH patients.
  • Cited by

    Periodical cited type(1)

    1. 汤戈,赵欣雨,王宇翔,冯鹏,魏彪. 工业CT技术在地球科学中的应用. CT理论与应用研究. 2024(01): 119-134 . 本站查看

    Other cited types(1)

Catalog

    Article views (677) PDF downloads (2) Cited by(2)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return