ISSN 1004-4140
CN 11-3017/P
HAO Yun, HE Jin-peng. Computer Assisted Surgery and Personal Orthopaedy of Patient with Knee Varus and Valgus[J]. CT Theory and Applications, 2016, 25(4): 393-401. DOI: 10.15953/j.1004-4140.2016.25.04.02
Citation: HAO Yun, HE Jin-peng. Computer Assisted Surgery and Personal Orthopaedy of Patient with Knee Varus and Valgus[J]. CT Theory and Applications, 2016, 25(4): 393-401. DOI: 10.15953/j.1004-4140.2016.25.04.02

Computer Assisted Surgery and Personal Orthopaedy of Patient with Knee Varus and Valgus

More Information
  • Received Date: February 25, 2016
  • Available Online: December 04, 2022
  • Published Date: August 24, 2016
  • Purpose: To explore a novel method of accurate measurement of patient with knee varus and valgus though computer assistant and the value been evaluated. Method: 14 patients admitted from Sep, 2010 to Sep, 2013, included 16 knees, consisted of 10 varus knees and 6 valgus knees. With computer assisted, appropriate osteotomy site and angle were selected and operation method planned. After operation, HSS evaluation was done compared with those scores before operation. Result: All patients were followed up between 3 to 12 months, the varus and valgus angle were quite well corrected, and the lower limb power lines were rebuilt. HSS scores were elevated from 52.6 ± 13.1 to 86.2 ± 8.9, respectively. Only 1 patient found infected, and cured with antibiotics. Conclusion: It is a valuable method to help a surgeon to make an operation plan for patients with knee varus and valgus diseases.
  • Related Articles

    [1]LIU Zhichao, XU Zhiwen, ZHAO Sai, ZHANG Youxin, NIE Cong, LEI Ziqiao. Deep Learning Computer-aided Diagnostic Model for Non-small Cell Lung Cancer Based on Convolutional Neural Network and Attention Mechanism[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.020
    [2]WANG Yongsheng, WANG Chensi, WU Jun, LI Changde, CHEN Wenjing. Application Value of Personalized Contrast Agent Injection Schemes of Different Durations in Pulmonary Artery CTA[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.010
    [3]XIONG Shan, CHEN Bo, MAO Jie, LIU Sibin, HUANG Yuanyi, CHENG Jianmin. Application of Computer-aided Diagnosis System Based on Deep Learning in Rib Fracture Diagnosis[J]. CT Theory and Applications, 2022, 31(5): 617-622. DOI: 10.15953/j.1004-4140.2022.31.05.08
    [4]HAO Fene, SUN Zhenting, GUO Youmin, ZHAO Lei, LIU Aishi. Reliable Study on Computer-aided Evaluation of the Severity of Acute Pulmonary Embolism[J]. CT Theory and Applications, 2020, 29(4): 456-464. DOI: 10.15953/j.1004-4140.2020.29.04.08
    [5]ZHU Huaqiang, LUO Dongmei, CAO Li, LIANG Mingli, YOU Rui, WU Bingyun. Application of Personalized Low Dose Spiral CT Scanning in the Examination of Thoracolumbar Trauma[J]. CT Theory and Applications, 2019, 28(1): 111-120. DOI: 10.15953/j.1004-4140.2019.28.01.12
    [6]LIU Lijun, HAO Fen'e, SUN Zhenting, MENG Lingxin, YANG Zhenxing, ZHAO Lei. Computer-aided Detection Low-dose CT for Early Lung Cancer Screening: A Feasibility Study[J]. CT Theory and Applications, 2019, 28(1): 39-44. DOI: 10.15953/j.1004-4140.2019.28.01.04
    [7]PENG Xiu-hua, GU Xiao-li, ZHANG Shi-yu, LIANG Zong-hui. The Study of 3D-ASL in Assessing Cerebral Blood Flow in Normal Persons[J]. CT Theory and Applications, 2018, 27(2): 241-248. DOI: 10.15953/j.1004-4140.2018.27.02.12
    [8]WAN Xin, LIU Xi-ming, WU Zhi-fang. Review of Computed laminography[J]. CT Theory and Applications, 2014, 23(5): 883-892.
    [9]Li Yubin, Li Xiangliang, Zhang Kuixiang, Cao Xulong. X-Ray Computed Micro-tomography(CMT) and Its Application to Petroleum Research[J]. CT Theory and Applications, 2000, 9(3): 35-40.
    [10]Li Jianding, Zhang Wenai, Chen Yongxin, Chen Yingli, Zhang Yaozhen. A Computer CT MRI Images Analysis and Diagnosis System for Cerebrovascular Disease[J]. CT Theory and Applications, 2000, 9(3): 12-14.
  • Cited by

    Periodical cited type(3)

    1. 李孝飞,覃庆婷,廖玉荣,杨利专,杨鹏,林炜南,冼昌源,曾晨茜,曹治婷. 前置呼吸模式在320排CT肺动脉双低成像的研究. 中国医学装备. 2024(01): 59-62 .
    2. 袁张强,路志凯. CT扫描诊断胸部肿瘤的临床价值分析. 影像研究与医学应用. 2021(19): 124-125 .
    3. 倪冠英,王雷,刘洋,张国晶. PET-CT对肺癌纵隔淋巴结转移的诊断效能及相关影响因素的研究. 中国辐射卫生. 2021(06): 771-775+781 .

    Other cited types(1)

Catalog

    Article views (571) PDF downloads (6) Cited by(4)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return