ISSN 1004-4140
CN 11-3017/P
Volume 25 Issue 6
Dec.  2016
Turn off MathJax
Article Contents
YANG Xiao-feng, ZHA Yun-fei, LI Liang. Effect of Volume Helical Shuttle Mode with ASiR Technique on the Quality of CT Perfusion Imaging in Liver Tumor[J]. CT Theory and Applications, 2016, 25(6): 717-723. DOI: 10.15953/j.1004-4140.2016.25.06.13
Citation: YANG Xiao-feng, ZHA Yun-fei, LI Liang. Effect of Volume Helical Shuttle Mode with ASiR Technique on the Quality of CT Perfusion Imaging in Liver Tumor[J]. CT Theory and Applications, 2016, 25(6): 717-723. DOI: 10.15953/j.1004-4140.2016.25.06.13

Effect of Volume Helical Shuttle Mode with ASiR Technique on the Quality of CT Perfusion Imaging in Liver Tumor

More Information
  • Received Date: August 14, 2016
  • Available Online: December 04, 2022
  • Published Date: December 24, 2016
  • Objective: To investigate the effect of VHS mode with ASi R on the quality of CT perfusion images of liver tumors. Methods: Twenty-eight patients with liver tumor underwent first-pass perfusion CT with volume helical shuttle technique. The raw date had been reconstructed by using FBP, the slice thickness being 2.5 mm. The CT values of aorta and the image noise were recorded for both groups. The parametric maps for the permeability surface(PS), blood volume(BV), blood flow(BF), transit time mean(MTT) were calculated. Paired samples t test or Wilcoxon signed sum test was used to analyze the difference.Image quality was assessed by two radiologists. Results: Compared with FBP reconstruction technique, 40% ASi R demonstrates low image noise((13.20 ±1.65) vs(10.9 ±1.49), P<0.01), with no statistical difference in CT values of aorta((58.33 ±9.19) vs(58.77 ±9.30), P=0.258). All the functional parameters of CT perfusion between two groups, including PS, BV, BF and MTT, showed no statistical difference. 40% ASi R group as quality score(4.14 ±0.36) higher than that of group FBP(3.79 ±0.48), the difference was statistically significant(P=0.001); Conclusion: Application of ASi R demonstrates no influence parameters acquired from CT perfusion with VHS mode in liver tumor, though the noise is lower than FBP.
  • Cited by

    Periodical cited type(3)

    1. 王凌云. 膀胱癌与腺性膀胱炎应用增强CT扫描的临床诊断价值. 临床研究. 2023(09): 140-142 .
    2. 徐敬慈,潘自来,陈克敏,陈小勇,刘霄. 纹理分析对CT引导下经皮肺穿刺活检术出血并发症的预测价值初探. CT理论与应用研究. 2022(03): 383-391 . 本站查看
    3. 王涛. 探讨64排螺旋CT图像后处理技术对膀胱癌的诊断价值. 影像研究与医学应用. 2021(21): 89-90 .

    Other cited types(0)

Catalog

    Article views (412) PDF downloads (7) Cited by(3)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return