ISSN 1004-4140
CN 11-3017/P
CAO Hong-wei, XING Yuan-yuan, CHOU Heng-zhi, ZHANG Dan, CAO Zhen-dong. The Comparison of Inferior Vena Cava Measurement by Direct and Indirect MSCT Venography[J]. CT Theory and Applications, 2017, 26(5): 599-604. DOI: 10.15953/j.1004-4140.2017.26.05.09
Citation: CAO Hong-wei, XING Yuan-yuan, CHOU Heng-zhi, ZHANG Dan, CAO Zhen-dong. The Comparison of Inferior Vena Cava Measurement by Direct and Indirect MSCT Venography[J]. CT Theory and Applications, 2017, 26(5): 599-604. DOI: 10.15953/j.1004-4140.2017.26.05.09

The Comparison of Inferior Vena Cava Measurement by Direct and Indirect MSCT Venography

More Information
  • Received Date: April 20, 2017
  • Available Online: December 01, 2022
  • Published Date: October 24, 2017
  • Objective: To measure the inferior vena cava diameters by direct and indirect MSCT angiography, and analysis whether there is difference between them. Method: Collecting 30 cases (M 14 cases, F 16 cases, ages 23~65 y, middle age 44y) which were underwent direct inferior vena cava venography, and collecting 30 cases (M 10 cases, F 20cases, ages 20~66 y, middle age 43y) of whole abdominal contrast enhanced CT, get the venous phase image. Original data were transferred to GE adw4.6 workstation for post-processing including MPR, MIP. The major axis, minor axis were individually measured, at the levels of its entrance to the right atrium, the portahepatis, the renal pelvis, above the junction of iliac vein. Measure the CT values where above 1cm the level left renal venous joined Inferior vena cava. Result: At the levels of its entrance to the right atrium, the portahepatis, the renal pelvis, above the junction of iliac vein, the major axis, minor axis of direct CT phlebography individually were (3.02 ±0.44, 2.06 ±0.32), (2.29 ±0.49, 1.39 ±0.52), (2.46 ±0.44, 1.73 ±0.45), (2.30 ±0.38, 1.66 ±0.46), of indirect phlebography individually were (2.88 ±0.43, 1.95 ±0.31), (2.37 ±0.59, 1.17 ±0.37), (2.28 ±0.32, 1.63 ±0.31), (2.25 ±0.21, 1.47 ±0.34), there is no obviously difference between them. The CT values of direct CTP where above 1cm the level left renal venous joined Inferior vena cava is (313.43 ±50.90) HU, much higher than the indirect CTV (95.50 ±22.17) HU. Conclusion: There was no significant difference between direct CTV and indirect CTV of the inferior vena cava diameters.
  • Related Articles

    [1]YIN Shuo, YANG Ying, XU Tongjiang, DENG Gang, CAO Shenhui, LIU Jianxin, YIN Xiaoming, LIANG Weizhong, WU Ge. Clinical Application of Multi-slice Spiral CT Scan in Chest for Costal Cartilage Augmentation Rhinoplasty[J]. CT Theory and Applications, 2021, 30(3): 347-353. DOI: 10.15953/j.1004-4140.2021.30.03.08
    [2]HUANG Wen-lei, SHEN Feng, YAO Xuan-jun, QIAN Bin. Diagnostic Value of Multi-slice Spiral CT on Differential Diagnosis of Peripheral Lung Cancer and Focal Machine Pneumonia[J]. CT Theory and Applications, 2018, 27(4): 529-536. DOI: 10.15953/j.1004-4140.2018.27.04.14
    [3]LI Gao-yang, ZHANG Dan, LV Liang, XING Yuan-yuan, WANG Ning, CHANG Ying-wei. Comparison of Image Quality of Iliac Vein in Lower Extremity Vein Direct Imaging by Multi-slice Spiral CT with Different Injection Rates[J]. CT Theory and Applications, 2018, 27(3): 401-409. DOI: 10.15953/j.1004-4140.2018.27.03.14
    [4]CAO Hong-wei, XING Yuan-yuan, CHOU Heng-zhi, ZHANG Dan, CAO Zhen-dong, WAN Li-ye, WANG Sheng-lin. The Effect of Contrast Medium Injection Rate on the Image Quality of Inferior Vena Cava Direct CTV[J]. CT Theory and Applications, 2017, 26(6): 775-782. DOI: 10.15953/j.1004-4140.2017.26.06.15
    [5]DONG Jian, YANG Lei, SUN Ying, SHEN Li-hui, YAN Nuan, WEN Jing, WEI Hai-liang, SUN Xiao-li, CHEN Xiao-bo, WEN Ting-guo, WANG Ren-gui. Low Tube Voltage Indirect CT Venography (CTV) in Lower limbs:A Potential Guidance for Varicose Vein in Preoperative Assessment[J]. CT Theory and Applications, 2017, 26(3): 365-372. DOI: 10.15953/j.1004-4140.2017.26.03.14
    [6]HONG Liang, YI Xu, YI Hong-bing. The Value Evaluation of Multi-slice Spiral CT in the Main Pulmonary Artery Hemodynamics of the Different Stages of Patients with Pneumoconiosis[J]. CT Theory and Applications, 2015, 24(2): 313-318. DOI: 10.15953/j.1004-4140.2015.24.02.17
    [7]DAI Yan-zeng, QIU Shu-fen, ZHANG Qiao-quan. Multi-Slice Spiral CT Post-Processing Techniques for the Diagnosis of the Tracheobronchial Foreign Bodies[J]. CT Theory and Applications, 2010, 19(1): 98-104.
    [8]XIANG Zi-yun, LIU Tao, ZHAN Yong. Multi-slice spiral CT in the Diagnosis of Vertebrobasilar Dolichectasia[J]. CT Theory and Applications, 2006, 15(4): 22-25.
    [9]HU Chun-feng, LI Jiang-shan, LI Shao-dong, WANG Xiu-ling, RONG Yu-tao, XU Kai. Clinical Application of Double-phase Multi-slice Spiral CT Angiography in Skull Base Meningioma[J]. CT Theory and Applications, 2006, 15(1): 6-10.
    [10]ZHANG Jia-li, WANG Hao, DENG Bi-yi, CUI Bing. Multi-spiral CT Diagnosis for Aortic Dissection[J]. CT Theory and Applications, 2003, 12(3): 22-25.
  • Cited by

    Periodical cited type(0)

    Other cited types(1)

Catalog

    Article views (605) PDF downloads (5) Cited by(1)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return