ISSN 1004-4140
CN 11-3017/P
MA Yu-tian, LIU Jun-biao, NIU Geng, ZHAO Wei-xia, HAN Li. Research on the Preparation and Performance of LaB6 Single Crystal Cathode for Micro-computed Tomography[J]. CT Theory and Applications, 2018, 27(3): 357-362. DOI: 10.15953/j.1004-4140.2018.27.03.08
Citation: MA Yu-tian, LIU Jun-biao, NIU Geng, ZHAO Wei-xia, HAN Li. Research on the Preparation and Performance of LaB6 Single Crystal Cathode for Micro-computed Tomography[J]. CT Theory and Applications, 2018, 27(3): 357-362. DOI: 10.15953/j.1004-4140.2018.27.03.08

Research on the Preparation and Performance of LaB6 Single Crystal Cathode for Micro-computed Tomography

More Information
  • Received Date: November 05, 2017
  • Available Online: November 07, 2021
  • The LaB6 single crystal tip was prepared by the method of drop-off electrochemical corrosion and the technique of focus ion beam. The micro topography of LaB6 single crystal tip was analyzed by scanning electron microscope. On this basis, the Vogel-type LaB6 single crystal cathode is prepared. The emission performance and its application in Micro-CT are studied. The experimental results indicate that the LaB6 single crystal cathode have higher brightness of electron beam, which can improved the X-ray intensity and the whole performance of Micro-CT.
  • Related Articles

    [1]CAO Jiasheng, LI Baolei. Analysis of Accuracy Related Factors in Photon Counting X-ray CT Energy Imaging[J]. CT Theory and Applications, 2025, 34(2): 255-262. DOI: 10.15953/j.ctta.2024.254
    [3]MA Yu-tian, LIU Jun-biao, NIU Geng, ZHAO Wei-xia, HAN Li. Research on the Preparation and Performance of Tungsten-diamond Transmission Target for Microfoucs X-ray Source[J]. CT Theory and Applications, 2017, 26(2): 189-194. DOI: 10.15953/j.1004-4140.2017.26.02.07
    [4]CHEN Yao, CHEN Ting, GUI Jian-bao, HU Zhan-li, Peter Z. WU, XIA Dan, ZHENG Hai-rong. Development of CNT Cathode Based X-ray Source and Imaging Technology[J]. CT Theory and Applications, 2013, 22(2): 363-372.
    [5]YANG Xiao-gang, YANG Li-rui. A Method on X-ray Security Image Enhancement[J]. CT Theory and Applications, 2012, 21(4): 705-712.
    [6]ZHANG Jun-sheng, WANG Ming-quan, GUO Yong-liang, CHEN Zhi-qiang. Analysis of X-ray Digital Imaging System Resolution[J]. CT Theory and Applications, 2011, 20(2): 227-234.
    [7]HAO Jia, ZHANG Li, CHEN Zhi-qiang, XING Yu-xiang, KANG Ke-jun. Multi-energy X-ray Imaging Technique and Its Application in Computed Tomography[J]. CT Theory and Applications, 2011, 20(1): 141-150.
    [8]CHEN Zhi-hua, PAN Lin, LI Hong-yan, LI Gang, XU Bo, WANG Zi-qiang, ZHU Pei-ping, ZHAO Tian-de, JIANG Xiao-ming, WU Zi-yu, TANG Jing-tian, CHEN Wei-chang. Principle and Advancements of X Ray Phase Contrast Micro-imaging[J]. CT Theory and Applications, 2005, 14(1): 52-56.
    [9]XI Yan-ping. Digitized X-ray Imaging Technique[J]. CT Theory and Applications, 2004, 13(2): 30-32.
    [10]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
  • Cited by

    Periodical cited type(3)

    1. 徐跃凡,茹亚东,左婷婷,伍岳,王鹏飞,刘俊标,高召顺,韩立,肖立业. LaB_6阴极的制备、应用与展望. 电子显微学报. 2024(02): 240-250 .
    2. 肖男,伍岳,高召顺,茹亚东,左婷婷,薛江丽,王岩,王鹏飞,韩立,刘俊标,阴生毅. 电子束阴极用LaB_6单晶的制备及其应用. 湘潭大学学报(自然科学版). 2021(01): 1-12 .
    3. 缪加巍,伍岳,高召顺,阴生毅,肖立业,韩立,马玉田,刘俊标,左婷婷. 热电子阴极材料LaB_6的单晶制备工艺与热发射性能研究. 电子显微学报. 2020(03): 256-260 .

    Other cited types(2)

Catalog

    Article views (472) PDF downloads (17) Cited by(5)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return