ISSN 1004-4140
CN 11-3017/P
Volume 27 Issue 6
Dec.  2018
Turn off MathJax
Article Contents
CHEN Rui-sen, XIA Jun, CHEN Jian-liang, LI Ai-dong, LI Xiang. Cross-sectional Study on the Relationship Between Integral Cognitive Level and Gray Matter Volume in Patients with Alzheimer's Disease Based on VBM[J]. CT Theory and Applications, 2018, 27(6): 709-717. DOI: 10.15953/j.1004-4140.2018.27.06.04
Citation: CHEN Rui-sen, XIA Jun, CHEN Jian-liang, LI Ai-dong, LI Xiang. Cross-sectional Study on the Relationship Between Integral Cognitive Level and Gray Matter Volume in Patients with Alzheimer's Disease Based on VBM[J]. CT Theory and Applications, 2018, 27(6): 709-717. DOI: 10.15953/j.1004-4140.2018.27.06.04

Cross-sectional Study on the Relationship Between Integral Cognitive Level and Gray Matter Volume in Patients with Alzheimer's Disease Based on VBM

More Information
  • Received Date: August 17, 2018
  • Available Online: November 07, 2021
  • Objective: To explore the relationship between integral cognitive level and gray matter volume in Alzheimer's disease (AD). Methods: 20 AD patients, 17 MCI patients and 12 healthy old persons were in this study.All subjects were examined by T1-3 D BRAVO (brain volume) sequence in 1.5 T magnetic resonance scanner. The volume of gray matter was measured with Voxel-based morphometry (VBM). All subjects were underwent MMSE and obtained the score of MMSE. The multiple regression analysis of gray matter volume were compared with MMSE score. Receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of gray matter volume in AD. Results: All of the subjects with reduced gray matter volume of brain, also reduce the MMSE score, gray matter volume decreased by 10 m L and MMSE score decreased by 0.56 points (P<0.01). The decline was more pronounced in men and in younger groups. The area under the curve (AUC) of the gray matter volume was 0.927. The optimum threshold was 538.49 m L, the specificity was 90.0% and the sensitivity was 84.6%. Conclusion: As the volume of gray matter decreased, the level of integral cognition also decreased. The gray matter volume in all patients and control group could reflect the integral cognitive level. The measurement of gray matter volume in the brain could provide valuable information for the diagnosis of AD.
  • Cited by

    Periodical cited type(4)

    1. 王亦君,张赫,刘毅,林福昌,徐尤来. 水介质预击穿过程液相温度纹影诊断技术研究. 真空科学与技术学报. 2024(02): 132-138 .
    2. 伍文霞,傅钰雯,舒文,杨健晟. 基于Abel逆变换的颜色法测量火焰当量比的研究. 智能计算机与应用. 2022(10): 123-129 .
    3. 张虎,何建萍,林杨胜蓝. 微束等离子弧焊电弧三维光谱及其抗干扰解耦. 光谱学与光谱分析. 2020(01): 48-53 .
    4. 徐云霞,文鹏飞,张如伟,张宝金,薛花. 无井波阻抗反演在西沙水合物研究中的应用. CT理论与应用研究. 2017(04): 425-434 . 本站查看

    Other cited types(3)

Catalog

    Article views (336) PDF downloads (8) Cited by(7)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return