  • Objective:To explore the application value of 80kV tube voltage combined with iterative reconstruction technology in CT angiography of lower extremity artery. Methods:40 patients were randomly divided into two groups. The parameters of scanning and injection were 80kV in the experimental group and 100kV in the control group. The radiation dose, contrast dose and image quality were compared between the two groups. Results:The effective radiation dose and contrast dose (95mL) of the control group were significantly higher than those of the experimental group, the difference was statistically significant (P<0.001); there was no statistical difference between the two groups in the CT value of vascular enhancement and the subjective score of image quality (P>0.05). Conclusion:The CT scanning technology of 80kV tube voltage combined with iterative reconstruction technology can significantly reduce the radiation dose and contrast agent dose on the premise of ensuring the image quality, which has important application and promotion value.
  • Related Articles

    [1]HU Yongzhi, WU Pengfei, CAO Da, WANG Binbin, TANG Yuxia, WANG Shouju, WANG Chuanbing. Elucidation of the Efficacy of Low Tube Voltage Combined with AIIR in Suppressing Hip Prosthesis CT Artifacts[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.334
    [2]QI Weiwei, CHENG Jin, CHEN Chuhan, AN Bei, LIU Xiaoyi, FU Ling, WANG Yi. Value of Low Tube Voltage Combined with Deep Learning Image Reconstruction Algorithm to Reduce Radiation Dose in Combined Thoracoabdominal Enhanced CT[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.001
    [3]JI Wenchao, TIAN Weili, LIU Wenya, HE Lianghao, YANG Jian. Application of the Canon 320 Row Variable Helical Pitch CTA System Combined with Iterative Reconstruction Technology for Lower Limb Vascular Imaging[J]. CT Theory and Applications, 2025, 34(1): 149-154. DOI: 10.15953/j.ctta.2024.009
    [4]JIANG Dong, QIN Lixin. Spectral Filtration Sn 150 kV Combined with Advanced Simulated Iterative Reconstruction in Lumbar Computed Tomography Examination[J]. CT Theory and Applications, 2024, 33(1): 49-55. DOI: 10.15953/j.ctta.2022.240
    [5]JIANG Yi, TIAN Kui, SHA Jinlu, QIN Lixin. Application of Energy Spectrum Purification Combined with Iterative Reconstruction Algorithm in Low-dose CT Examination of Patients with Secondary Pulmonary Tuberculosis[J]. CT Theory and Applications, 2022, 31(1): 95-101. DOI: 10.15953/j.1004-4140.2022.31.01.11
    [6]JIANG Yi, QIN Lixin, TIAN Kui, SHA Jinlu, ZHOU Chunhua. Clinical Value of Double Low Examination Technique Based on KARL 3D Iterative Reconstruction Algorithm in Bronchial Artery Imaging[J]. CT Theory and Applications, 2021, 30(6): 753-760. DOI: 10.15953/j.1004-4140.2021.30.06.11
    [7]XIA Zhenying, SUN Jun, WANG Xing, WU Dan, DING Jinli, LI Hongjun. Application of iDose4 Iterative Reconstruction on Low Dose CT Scanning in AIDS Patients with PJP[J]. CT Theory and Applications, 2020, 29(2): 195-202. DOI: 10.15953/j.1004-4140.2020.29.02.10
    [8]HU Qi-yun, DONG Yue, ZHANG Rui, WANG Fei-fei, DONG Rui-tong, LUO Ya-hong, WANG Zhang-de. The Study of Low-dose Computed Tomography with Iterative Reconstruction in Neck[J]. CT Theory and Applications, 2018, 27(4): 447-453. DOI: 10.15953/j.1004-4140.2018.27.04.04
    [9]CHANG Shao-jie, MOU Xuan-qin. An Iterative Algorithm with Simultaneously Updating the Spectrum and the Image of Dual Energy Computed Tomography[J]. CT Theory and Applications, 2018, 27(1): 45-54. DOI: 10.15953/j.1004-4140.2018.27.01.06
    [10]HONG Wei, CHU Ying, MOU Xuan-qin. Model-guided Iterative Reconstruction for Limited-angle CT Image[J]. CT Theory and Applications, 2012, 21(4): 597-604.

Catalog

    Article views (417) PDF downloads (14) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return