ISSN 1004-4140
CN 11-3017/P
Volume 30 Issue 2
Apr.  2021
Turn off MathJax
Article Contents
GAO Shuai, ZHAO Teng, GU Hua, JIANG Tao, LI Hui, LI Xinyue, WEI Bojun. The Value of Four-dimensional Dual Energy CT on Diagnosis of Parathyroid Adenoma[J]. CT Theory and Applications, 2021, 30(2): 244-252. DOI: 10.15953/j.1004-4140.2021.30.02.12
Citation: GAO Shuai, ZHAO Teng, GU Hua, JIANG Tao, LI Hui, LI Xinyue, WEI Bojun. The Value of Four-dimensional Dual Energy CT on Diagnosis of Parathyroid Adenoma[J]. CT Theory and Applications, 2021, 30(2): 244-252. DOI: 10.15953/j.1004-4140.2021.30.02.12

The Value of Four-dimensional Dual Energy CT on Diagnosis of Parathyroid Adenoma

More Information
  • Received Date: January 18, 2020
  • Available Online: November 05, 2021
  • Objective: To investigate the imaging characteristics and material tissue characteristics of parathyroid adenoma(PA) with four-dimensional dual energy computed tomography(4D-DECT), and to evaluate the value of localization and qualitative diagnosis. Materials and methods: the clinical and 4D-DECT imaging data of 53 patients with PA confirmed by operation and pathology were retrospectively analyzed. The CT signs were observed and recorded, and CT value, iodine concentration, Rho, Z value and DEI were measured and analyzed. Results: In 53 patients, 52(98.11%) cases of PA were solitary, 1(1.89%) case with multiple nodules, a total of 54 lesions were found, 32(59.26%) of which were located in the trachea-esophageal sulcus, 10(18.52%) lesions were ectopic adenomas, and 22(40.74%) lesions showed "short line sign", 14(25.93%) showed "polar vessel sign"; there was no significant difference in CT value between PA and thyroid in arterial phase(90 kV), but the CT value of PA, thyroid and lymph nodes were different in non-contrast, arterial phase(M 0.5, 150 kV) and venous phase(90 kV, M 0.5, 150 kV). Iodine concentration, Z value and DEI of lymph nodes in arterial and venous phase were significantly lower than those of PA and thyroid, iodine concentration, Z value and DEI of PA in venous phase were significantly lower than those of thyroid; Rho of thyroid in arterial and venous phase was significantly higher than that of PA, and Rho of PA in arterial phase was significantly higher than that of lymph nodes. Conclusion: 4D-DECT can better display the imaging features of PA, and can also provide the analysis of iodine concentration and a variety of material tissue characteristics information, which is helpful to improve the diagnostic accuracy of PA.
  • Cited by

    Periodical cited type(5)

    1. 上官宏,任慧莹,张雄,韩兴隆,桂志国,王燕玲. 基于双编码器双解码器GAN的低剂量CT降噪模型. 计算机应用. 2025(02): 624-632 .
    2. 陈辉艳,王映飞,梁莎,许大幸. 孕妇儿童肺部疾病多模态磁共振扫描应用研究进展. 实用医学影像杂志. 2023(05): 373-375 .
    3. 朱元正,吕启闻,官瑜,刘且根. 基于深度能量模型的低剂量CT重建. CT理论与应用研究. 2022(06): 709-720 . 本站查看
    4. 栗乔新,金科,庞志峰. 一种去除CT图像中同心椭圆伪影的变分模型. CT理论与应用研究. 2022(06): 773-781 . 本站查看
    5. 吴凡,刘进,张意,陈阳,陆志凯. 面向CT成像的深度重建算法研究进展. 中国体视学与图像分析. 2022(04): 387-404 .

    Other cited types(12)

Catalog

    Article views (407) PDF downloads (11) Cited by(17)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return