ISSN 1004-4140
CN 11-3017/P
YIN Shuo, YANG Ying, XU Tongjiang, DENG Gang, CAO Shenhui, LIU Jianxin, YIN Xiaoming, LIANG Weizhong, WU Ge. Clinical Application of Multi-slice Spiral CT Scan in Chest for Costal Cartilage Augmentation Rhinoplasty[J]. CT Theory and Applications, 2021, 30(3): 347-353. DOI: 10.15953/j.1004-4140.2021.30.03.08
Citation: YIN Shuo, YANG Ying, XU Tongjiang, DENG Gang, CAO Shenhui, LIU Jianxin, YIN Xiaoming, LIANG Weizhong, WU Ge. Clinical Application of Multi-slice Spiral CT Scan in Chest for Costal Cartilage Augmentation Rhinoplasty[J]. CT Theory and Applications, 2021, 30(3): 347-353. DOI: 10.15953/j.1004-4140.2021.30.03.08

Clinical Application of Multi-slice Spiral CT Scan in Chest for Costal Cartilage Augmentation Rhinoplasty

More Information
  • Received Date: December 22, 2020
  • Available Online: November 05, 2021
  • objective:To evaluate the value of multislice spiral CT-Chest Scan in costal cartilage augmentation rhinectomy. Methods: 120 patients undergoing autologous costal cartilage augmentation rhinorrhea were examined by multislice spiral CT before operation, and various three-dimensional reconstruction was performed to analyze whether the autogenous costal cartilage was in accordance with the surgical standard. Some cases were reviewed and evaluated by CT after operation. Results: CT accurately evaluated 28 cases of non-calcification of costal cartilage(grade 1) and 62 cases of mild calcification(grade 2), all of which could be performed augmentation rhinectomy with autologous costal cartilage. 23 cases of moderate calcification(grade 3), of the 23 cases, 12 were avaiable. The remaining 11 cases and all severe calcification(grade 4) 7 cases gave up costal cartilage directly and performed augmentation rhinoplasty with ear cartilage replacement. At the same time, 3 cases of forked ribs, 7 cases of partial fusion of costal cartilage, 1 case of endoscopic right heart with visceral torsion and 2 cases of pulmonary space occupying lesions were also found. Conclusion: multislice spiral CT and various three-dimensional reconstruction are the first choice of imaging examination for patients who want to perform augmentation rhinectomy with autologous costal cartilage. It can accurately evaluate whether there is calcification and degree of autochial cartilage, and can accurately measure the actual course, length, width and thickness of each costal cartilage, which can provide reliable preoperative imaging information for costal cartilage augmentation rhinectomy. At the same time, it can also evaluate the effect of transplantation and detect complications after operation and so on.
  • Related Articles

    [1]JIANG Yang, TANG Wentao, HU Ran, HU Qinqin, LI Gangjing, ZHANG Hao, YU Ting, ZHANG Dechuan. Impact of Individual Body Shape Factors and Tissue Contents on the Water Equivalent Diameter of Size-Specific Dose Estimations in Adult Chest CT[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.272
    [2]LEI Lixing, HUANG Xiaohua, LIU Nian, TANG Lingling, MA Linjun. Analysis of Accuracy, Image Quality, and Effective Dose of Coronary CT Angiography Using Dual-Source CT with Turbo-Flash Mode to Evaluate Coronary Artery Stenosis[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.350
    [3]LIU Yuhang, LI Wei, NIU Yantao, ZHANG Yongxian, WANG Yuchen, YANG Bingbing, LIU dandan. Low-Dose Study on Coronary Artery Calcium Score Scanning Using the SEMI Mode of the Intelligent Optimal Tube Voltage Selection Technique in Combination with an Iterative Algorithm[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.317
    [4]Ma Wentao, Zhang Yongxian, Guo Senlin, Liu Yunfu, Kang Tianliang. Study on the Impact of Different Tube Voltages Combined with Organ Dose Modulation on Cerebral Perfusion Image Quality and Ocular Lens Radiation Dose[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.337
    [5]FENG Mengya, LI Bing, WU Min, HUA Ting, TANG Guangyu. Application of New Iterative Reconstruction Algorithm Based on Artificial Intelligence and Low Tube Voltage in Reducing the Radiation Dose of Coronary CTA in Obese Patients[J]. CT Theory and Applications, 2023, 32(6): 777-782. DOI: 10.15953/j.ctta.2022.148
    [6]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [7]LIANG Hong-sheng, CHEN Jin-jun, CHEN Xiao-yu, LIANG Yu-hao, OU Jian-yang, MA Guan-hua. Dose 4D CARE Technology Combined with Low kV and Low Dose Contrast Agent in MSCT Head and Neck Vascular Imaging Applications[J]. CT Theory and Applications, 2017, 26(5): 605-612. DOI: 10.15953/j.1004-4140.2017.26.05.10
    [8]TIAN Zhi-nan, LONG Shi-liang, ZHAO Yue, TAN Hong-wen. Feasibility of 80 kVp Ultra-low Dose Scan Protocol in Prospective Coronary CT Angiography[J]. CT Theory and Applications, 2017, 26(1): 99-106. DOI: 10.15953/j.1004-4140.2017.26.01.13
    [9]BAO Li-wei, WANG Ze-feng, SUN Zhen-ting, MENG Ling-xin, ZHAO Lei. Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA[J]. CT Theory and Applications, 2015, 24(1): 87-94. DOI: 10.15953/j.1004-4140.2015.24.01.10
    [10]LI Ruo-mei, WANG Si-wei, JIN Dan-dan. Low-dose CT Coronary Angiography with Status Quo of Tube Current and Voltage Parameters Optimization[J]. CT Theory and Applications, 2012, 21(3): 515-520.
  • Cited by

    Periodical cited type(2)

    1. 涂立冬,李雅萍. 岩土勘查技术在盐矿绿色矿山建设中的应用初探. 盐科学与化工. 2025(04): 9-12 .
    2. 杨兆林,潘懿,白旭晨,刘禄平. 露天铁矿采空区隐蔽致灾普查与防治措施应用研究. 矿业研究与开发. 2024(09): 74-81 .

    Other cited types(2)

Catalog

    Article views PDF downloads Cited by(4)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return