Citation: | WANG C, ZHOU F Y, XUAN Y J, et al. Measurement and Analysis of Gonadal Irradiation Dose During Singe-shot X-ray Exposure of Both Lower Limbs[J]. CT Theory and Applications, 2024, 33(5): 627-632. DOI: 10.15953/j.ctta.2023.171. (in Chinese). |
Objective: To investigate the relationship between entrance surface dose (ESD) of gonads and physiological parameters such as sex, age, height, and weight in digital X-ray exposure of both lower limbs and to explore the feasibility of full-width long-plate imaging with single-dose radiation exposure. Methods: A total of 300 patients at a weight-bearing position of both lower limbs were prospectively enrolled in a hospital in Beijing, including 129 males and 171 females. The TLD detectors were set at the gonads on both sides of the patient during scanning. After exposure, the TLD detectors were measured with an RGD-3B thermoluminescence dosimeter, and the corresponding dose values were obtained and analyzed. Results: The average triple exposure dose (AP+bilateral view) in the full-length plate adult mode was (1281±202) µGy, which was approximately three times the single exposure dose (429±99) µGy. The triple exposure dose (AP+bilateral view) was significantly lower than the radiation dose recommended by international standards. Multiple linear regression analysis showed that only height and weight affected gonadal radiation dose. Under the scanning parameters of children, the ESD dose was (359±27) µGy and (627±155) µGy when the height was less or more than 160 cm, respectively, with a significant statistical difference. In adult mode, height and weight did not affect the ESD dose. Conclusions: This study showed that the exposure dose of gonads during full-length scanning of both lower limbs in a weight-bearing position with a single exposure was affected by height and weight. The dose received by the gonads was within the safe range, and a single exposure of the full-length plate radiation dose is feasible in clinical practice.
[1] |
王芳, 马丽文, 张国勇, 等. DR双下肢全长摄影在临床中的应用现状[J]. 现代医药卫生, 2022, 38(23): 4059−4062. DOI: 10.3969/j.issn.1009-5519.2022.23.021.
WANG F, MA L W, ZHANG G Y, et al. Application status of DR bilateral lower limb full-length radiography in clinical practice[J]. Modern Medicine & Health, 2022, 38(23): 4059−4062. DOI: 10.3969/j.issn.1009-5519.2022.23.021. (in Chinese).
|
[2] |
Van BILJON L, FASHEMI B, RODRIGUEZ J, et al. Visualizing DNA damage repair proteins in patient-derived ovarian cancer organoids via immunofluorescence assays[J]. Journal of Visualized Experiments, 2023, 24(192): 10.3791/64881. DOI: 10.3791/64881.
|
[3] |
LIU C, LIAO W, CHEN J, et al. Cholesterol confers ferroptosis resistance onto myeloid-biased hematopoietic stem cells and prevents irradiation-induced myelosuppression[J]. Redox Biology, 2023, 62: 102661. DOI: 10.1016/j.redox.2023.102661.
|
[4] |
PICONE C, FUSCO R, TONERINI M, et al. Dose reduction strategies for pregnant women in emergency settings[J]. Journal of Clinical Medicine, 2023, 12(5): 1847. DOI: 10.3390/jcm12051847.
|
[5] |
杨娟, 曾慧红, 邵立健. 电离辐射对睾丸生殖功能的影响[J]. 临床与病理杂志, 2022, 42(9): 2274−2283. DOI: 10.3978/j.issn.2095-6959.2022.09.033.
YANG J, ZENG H H, SHAO L J. The impact of ionizing radiation on testicular reproductive function[J]. Journal of Clinical and Pathological Research, 2022, 42(9): 2274−2283. DOI: 10.3978/j.issn.2095-6959.2022.09.033. (in Chinese).
|
[6] |
LIN C M, CHANG W P, DOYLE P, et al. Prolonged time to pregnancy in residents exposed to ionising radiation in cobalt-60-contaminated buildings[J]. Occupational and Environmental Medicine, 2010, 67(3): 187−195. DOI: 10.1136/oem.2008.045260.
|
[7] |
王月娇, 袁素娥. 电离辐射对医务人员生殖系统的影响及防护的研究进展[J]. 护理研究, 2017, 31(11): 1291−1295. DOI: 10.3969/j.issn.1009-6493.2017.11.004.
WANG Y J, YUAN S E. Research progress on the effects of ionizing radiation on the reproductive system of medical personnel and protection[J]. Nursing Research, 2017, 31(11): 1291−1295. DOI: 10.3969/j.issn.1009-6493.2017.11.004. (in Chinese).
|
[8] |
PUY V, BARROCA V, MESSIAEN S, et al. Mouse model of radiation-induced premature ovarian insufficiency reveals compromised oocyte quality: Implications for fertility preservation[J]. Reproductive Biomedicine Online, 2021, 43(5): 799−809. DOI: 10.1016/j.rbmo.2021.06.027.
|
[9] |
于楠, 屈明玥, 王凯, 等. 电离辐射对男性生殖系统的危害及其预防[J]. 解放军预防医学杂志, 2020, 38(10): 36−38. DOI: 10.13704/j.cnki.jyyx.2020.10.012.
YU N, QU M Y, WANG K, et al. Harm and prevention of ionizing radiation on male reproductive system[J]. Military Medical Journal of PLA, 2020, 38(10): 36−38. DOI: 10.13704/j.cnki.jyyx.2020.10.012. (in Chinese).
|
[10] |
ICRP第147号出版物《放射防护中使用的剂量量》内容摘要[J]. 辐射防护通讯, 2022, 42(1): 30-31.
Summary of the Content of ICRP Publication 147: Dose Quantities Used in Radiation Protection[J]. Radiation Protection Communication, 2022, 42(1): 30-31. (in Chinese).
|
[11] |
DELIN C, SILVERA S, BASSINET C, et al. Ionizing radiation doses during lower limb torsion and anteversion measurements by EOS stereoradiography and computed tomography[J]. European Journal of Radiology, 2014, 83(2): 371−377. DOI: 10.1016/j.ejrad.2013.10.026.
|
[12] |
LEE K H, KWON J W, YOON Y C, et al. Slot-scan digital radiography of the lower extremities: A comparison to computed radiography with respect to image quality and radiation dose[J]. Korean Journal of Radiology, 2009, 10(1): 51−57. DOI: 10.3348/kjr.2009.10.1.51.
|
[13] |
MUSSMANN B, JENSEN C, BENSEN A S, et al. Radiographic signs of acetabular retroversion using a low-dose slot-scanning radiographic system (EOS(®))[J]. Radiography (Lond), 2019, 25(3): e53−e57. DOI: 10.1016/j.radi.2019.01.001.
|
[14] |
DIETRICH T J, PFIRRMANN C W, SCHWAB A, et al. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography[J]. Skeletal Radiology, 2013, 42(7): 959−967. DOI: 10.1007/s00256-013-1600-0.
|
[15] |
CHIRON P, DEMOULIN L, WYTRYKOWSKI K, et al. Radiation dose and magnification in pelvic X-ray: EOS™ imaging system versus plain radiographs[J]. Orthopaedics & Traumatology: Surgery & Research, 2017, 103(8): 1155−1159. DOI: 10.1016/j.otsr.2017.07.018.
|
[16] |
李巍伟. 两种小儿胸部DR摄影体位在眼晶状体辐射剂量方面对比研究[J]. 影像技术, 2020, 32(1): 4−5, 20. DOI: 10.3969/j.issn.1001-0270.2020.01.01.
LI W W. Comparative study on the radiation dose to the eye lens in two pediatric chest DR imaging positions[J]. Imaging Technology, 2020, 32(1): 4−5, 20. DOI: 10.3969/j.issn.1001-0270.2020.01.01. (in Chinese).
|
[17] |
KUMAR R, de JESUS O. Radiation effects on the fetus[M]//StatPearls. Treasure Island (FL): StatPearls Publishing Copyright, 2022, StatPearls Publishing LLC., 2022.
|
[18] |
BONE C M, HSIEH G H. The risk of carcinogenesis from radiographs to pediatric orthopaedic patients[J]. Journal of Pediatric Orthopaedics, 2000, 20(2): 251−254. DOI: 10.1302/0301-620X.101B3.BJJ-2018-0663.R1.
|
[19] |
SHAPIRA S, NITECKI M, TZUR D, et al. Occupational exposure to nonionizing radiation and risk for malignancy in young adults[J]. Military Medicine, 2023, 188(7/8): e2424-e2430. DOI:10.1093/milmed/ usad020.
|
[20] |
ABDELRAHMAN M, LOMBARDO P, DABIN J, et al. Impact of the implementation of the new radiation quantities recommended by ICRU/ICRP for practical use in interventional radiology: A Monte Carlo study[J]. Journal of Radiological Protection, 2023, 43(1). DOI: 10.1088/1361-6498/acb780.
|
[21] |
HUDA W, NICKOLOFF E L, BOONE J M. Overview of patient dosimetry in diagnostic radiology in the USA for the past 50 years[J]. Medical Physics, 2008, 35(12): 5713−5728. DOI: 10.1118/1.3013604.
|
[22] |
VANO E. ICRP recommendations on 'Managing patient dose in digital radiology[J]. Radiation Protection Dosimetry, 2005, 114(1/3): 126−130. DOI: 10.1093/rpd/nch533.
|
[23] |
METTLER F. Managing patient dose in digital radiology: A report of the International Commission on Radiological Protection[J]. Annals of the ICRP, 2004, 34(1): 1−73. DOI: 10.1016/j.icrp.2004.02.001.
|
1. |
倪晓龙,周凤云,施政,马永忠,程晓光. 基于剂量模拟人的腹部CT扫描辐射剂量分布研究. CT理论与应用研究. 2024(06): 808-814 .
![]() |