Citation: | HU Y J, WEI X, ZHANG Y, et al. Effect of External Foreign Bodies on Patient Radiation Dose in Chest CT[J]. CT Theory and Applications, 2025, 34(5): 1-6. DOI: 10.15953/j.ctta.2025.103. (in Chinese). |
To investigate the effect of external foreign bodies on radiation dose during chest computed tomography (CT) scans under automatic tube current-modulation technology and to assess the necessity of re-scanning a scout image, we retrospectively categorize historical data into foreign body and non-foreign body cohorts. Propensity score matching is employed to balance five covariates: patient gender, examination age, number of image layers, scanning-bed height, and average cross-sectional area of patients. After balancing, we statistically analyze the effect of foreign bodies on the volume CT dose index (CTDIvol) and dose-length product (DLP), and compare the dose increment with the scout-image dose. The study includes
[1] |
TSALAFOUTAS I A, ALKHAZZAM S, ALNAEMI H, et al. Evaluation of automatic tube current modulation of CT scanners using a dedicated and the CTDI dosimetry phantoms[J]. Journal of Applied Clinical Medical Physics, 2022, 23(7): e13620. DOI: 10.1002/acm2.13620.
|
[2] |
吴德红, 陈少波, 付传明, 等. ATCM技术在CTU中降低辐射剂量的应用探讨[J]. CT理论与应用研究, 2015, 24(2): 319-325. DOI: 10.15953/j.1004-4140.2015.24.02.18.
WU D H, CHEN S B, FU C M, et al. Value of automatic tube current modulation techniques to reducing the radiation dose in CTU[J]. CT Theory and Applications, 2015, 24(2): 319-325. DOI: 10.15953/j.1004-4140.2015.24.02.18. (in Chinese).
|
[3] |
AUSTIN P C. A critical appraisal of propensity-score matching in the medical literature between 1996 and 2003[J]. Statistics in Medicine, 2008, 27(12): 2037-2049. DOI: 10.1002/sim.3150.
|
[4] |
ROSENBAUM P R, RUBIN D B. Constructing a control group using multivariate matched sampling methods that incorporate the propensity score[J]. The American Statistician, 1985, 39(1): 33-38. DOI: 10.1080/00031305.1985.10479383.
|
[5] |
冉姗姗, 綦维维, 张淼, 等. 多参数设置对低剂量胸部CT扫描图像质量及辐射剂量的影响[J]. 中国医学影像技术, 2018, 34(1): 113-117. DOI: 10.13929/j.1003-3289.201704039.
RAN S S, QI W W, ZHANG M, et al. Impact of multiple parameters setting on image quality and radiation dose in low-dose chest CT scanning[J]. Chinese Journal of Medical Imaging Technology, 2018, 34(1): 113-117. DOI: 10.13929/j.1003-3289.201704039. (in Chinese).
|
[6] |
刘丹丹, 崔莹, 赵波, 等. 定位像扫描参数对胸部CT影像质量和辐射剂量影响的模体研究[J]. 中华放射医学与防护杂志, 2021, 41(3): 217-221. DOI: 10.3760/cma.j.issn.0254-5098.2021.03.011.
LIU D D, CUI Y, ZHAO B, et al. The influence of scout scanning parameters on image quality and radiation dose of chest CT: A phantom study[J]. Chinese Journal of Radiological Medicine and Protection, 2021, 41(3): 217-221. DOI: 10.3760/cma.j.issn.0254-5098.2021.03.011. (in Chinese).
|
[7] |
杨政君, 张昂, 陈勇, 等. 辐射剂量和管电压对CT图像质量的影响: 基于任务的图像质量评价[J]. CT理论与应用研究, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060.
YANG Z J, ZHANG A, CHEN Y, et al. The effect of radiation dose and tube potential on image quality of CT: A task-based image quality assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060. (in Chinese).
|
[8] |
李海梅, 刘康, 隋岩, 等. 不同CT扫描条件对胸部模体实性结节人工智能检出效率及辐射剂量的影响[J]. 中华放射医学与防护杂志, 2023, 43(3): 216-221. DOI: 10.3760/cma.j.cn112271-20221114-00446.
LI H M, LIU K, SUI Y, et al. The influence of different CT scanning protocols on AI detection efficiency and radiation dose of solid nodules in chest phantom[J]. Chinese Journal of Radiological Medicine and Protection, 2023, 43(3): 216-221. DOI: 10.3760/cma.j.cn112271-20221114-00446. (in Chinese).
|
[9] |
张宇, 何长久, 杨梦犀, 等. 自动管电压联合自动管电流在冠状动脉CT血管成像中的应用[J]. 中国医疗设备, 2023, 38(5): 115-119. DOI: 10.3969/j.issn.1674-1633.2023.05.021.
ZHANG Y, HE C J, YANG M X, et al. Application of automatic tube voltage combined with automatic tube current techniques in coronary CT angiography[J]. China Medical Devices, 2023, 38(5): 115-119. DOI: 10.3969/j.issn.1674-1633.2023.05.021. (in Chinese).
|
[10] |
邵培育, 苏小蓉. 自动管电流调制技术对腹部CT图像质量及辐射剂量的影响[J]. 医疗装备, 2022, 35(22): 32-34. DOI: 10.3969/j.issn.1002-2376.2022.22.010.
|
[11] |
罗锐. 探讨双源CT自动管电流调制技术在冠状动脉成像中降低辐射剂量的价值[J]. 影像研究与医学应用, 2020, 4(3): 17-18.
LUO R. To explore the value of dual-source CT automatic tube current modulation technique in reducing radiation dose in coronary artery imaging[J]. Journal of Imaging Research and Medical Applications, 2020, 4(3): 17-18. (in Chinese).
|
[12] |
李翔, 王翔, 杨欣, 等. 自动管电流技术联合人工智能在COVID-19肺部低剂量CT中的应用价值[J]. 放射学实践, 2020, 35(9): 1082-1086. DOI: 10.13609/j.cnki.1000-0313.2020.09.001.
LI X, WANG X, YANG X, et al. Application of automatic tube current technique combined with artificial intelligence in the low dose CT for COVID-19[J]. Radiologic Practice, 2020, 35(9): 1082-1086. DOI: 10.13609/j.cnki.1000-0313.2020.09.001. (in Chinese).
|
[13] |
黄涛, 马隆佰, 陆玉敏, 等. 80kV管电压下迭代重建算法联合自动管电流调制技术在低剂量头颈部CT血管造影中的应用[J]. 广西医学, 2020, 42(18): 2364-2368. DOI: 10.11675/j.issn.0253-4304.2020.18.09.
HUANG T, MA L B, LU Y M, et al. Application of iterative reconstruction algorithm combined with automatic tube current modulation technology to low-dose computed tomography angiography of head and neck in the setting of tube voltage of 80kV[J]. Guangxi Medical Journal, 2020, 42(18): 2364-2368. DOI: 10.11675/j.issn.0253-4304.2020.18.09. (in Chinese).
|