ISSN 1004-4140
CN 11-3017/P
YUAN Pei-xin, NIU Yan-ping. Thickness Evaluation of Pipes Using X-ray Real-time Radiographs[J]. CT Theory and Applications, 2007, 16(3): 36-42.
Citation: YUAN Pei-xin, NIU Yan-ping. Thickness Evaluation of Pipes Using X-ray Real-time Radiographs[J]. CT Theory and Applications, 2007, 16(3): 36-42.

Thickness Evaluation of Pipes Using X-ray Real-time Radiographs

More Information
  • Received Date: March 19, 2007
  • Available Online: December 16, 2022
  • Along with the fast development of NDT,X-ray Real-time radiographic method obtains great application.This paper discussed X-ray Real-time Radiographs detecting method research on insulated pipes,and this text emphasizes the experimental method of determining corrupt thickness of pipes and establishes the thickness mathematic model of the pipes.Consequently,we can make sure the corrupt thickness of pipes.The measurable research about pipe corrupt thickness helps to evaluate the safety of pipes and discover the hidden trouble in time.
  • Related Articles

    [1]LIU Qiegen, GUAN Yu, WU Weiwen, SHAN Hongming, LIANG Dong. Diffusion Models in Medical Imaging: A Comprehensive Survey[J]. CT Theory and Applications, 2025, 34(3): 506-524. DOI: 10.15953/j.ctta.2024.316
    [2]JIN Xin, ZHANG Siyuan, LI Liang, CHEN Zhiqiang. A Dual-energy Stationary CT System Based on Dual-plane Scanning Mode[J]. CT Theory and Applications, 2020, 29(1): 31-37. DOI: 10.15953/j.1004-4140.2020.29.01.04
    [3]LIU Zhe, ZHANG Li. Review of γ-ray CT for Radioactive Waste Assay[J]. CT Theory and Applications, 2014, 23(6): 1025-1040.
    [4]TANG Zi-shu, LIU Jie, BIE Shu-lin. Study of CT Image Segmentation Based on CV Model[J]. CT Theory and Applications, 2014, 23(2): 193-202.
    [5]ZHANG Jian, WANG Xue-wu, SUN Yun-da. The Application of Neural Network Model for X-ray Image Fusion[J]. CT Theory and Applications, 2011, 20(2): 235-243.
    [6]YANG Ke-cheng, YE Yu-sheng, YU Xiao-e, LIN Yi-qun. Modeling of three-dimensional CT imaging[J]. CT Theory and Applications, 2006, 15(1): 37-41.
    [7]SHI Xiao-le, SHENG Qiang, LI Yu-bin. CT Scanning Tracking Technique for Man-made Experimental Model for Oil Driven by Water[J]. CT Theory and Applications, 2003, 12(2): 26-29.
    [8]CENG Xiang-zhao. X-ray Real-time Image to Detect Minimum Defect Examination and Getting the best Magnification[J]. CT Theory and Applications, 2002, 11(4): 13-16.
    [9]LUO Guo-cheng, ZHAO Yong-jie. Heart Contour fitting in PET Image Using Mathematical Morphology and Spline Model[J]. CT Theory and Applications, 2002, 11(3): 1-6.
    [10]Yang Xuhai, Zhang Xiaochun. The Mathematical Definition Of Original Digital Image And the Abstraction of Stripe Noise[J]. CT Theory and Applications, 2001, 10(3): 42-46.

Catalog

    Article views (667) PDF downloads (4) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return