ISSN 1004-4140
CN 11-3017/P
YANG Li-min, XU Kai, GU Yu-ming. Clinical Application of 3D and MIP with MSCT in Hepatic Carcinoma with Arterioportal Shunt[J]. CT Theory and Applications, 2007, 16(4): 44-50.
Citation: YANG Li-min, XU Kai, GU Yu-ming. Clinical Application of 3D and MIP with MSCT in Hepatic Carcinoma with Arterioportal Shunt[J]. CT Theory and Applications, 2007, 16(4): 44-50.

Clinical Application of 3D and MIP with MSCT in Hepatic Carcinoma with Arterioportal Shunt

More Information
  • Received Date: September 06, 2007
  • Available Online: December 16, 2022
  • Objective: To investigate the clinical applicable value of three-dimensional(3D) and maximum intensity projection(MIP) with 16-row helical CT in diagnosing the hepatic carcinoma with arterioportal shunt.Methods: 64 Cases of hepatic carcinoma with arterioportal shunt underwent 16-row helical CT enhanced volume scans.To be reconstructed with MIP and 3D techniques,All reconstructed imagines were observed and analysed(compaired with imagines of trans-axia and DSA).Results: 16-row helical CT MIP and 3D reconstruction could produce clear and comprehensive images of the hepatic carcinoma with arterioportal shunt,and produce the change of hemodynamics which resulted in arterioportal shunt.Conclusion: 16-row helical CT MIP and 3D reconstruction as important techniques of trans-axial,could display the characteristical of the hepatic carcinoma with arterioportal shunt with no traumatic,intuitionistic and quickly,which could afford the powerful evidence for clinical diagnose and treat with the hepatic carcinoma with arterioportal shunt.
  • Related Articles

    [1]HUANG Jieling, LI Yuanzhang, LI Liangjie, YUAN Qinghua. The Diagnostic Value of Gd-Eob-Dtpa Enhanced MRI in Hepatocellular Carcinoma in Liver Cirrhosis[J]. CT Theory and Applications, 2019, 28(4): 485-492. DOI: 10.15953/j.1004-4140.2019.28.04.10
    [2]LIU Min, LIN Yisheng, WANG Fangjun, LI Weihao, LIU Qiong, BAI Chenhui. Correlation of Image Quality and Angiographic Parameters in Two Groups of Angiocatheter by Hepatocellular Carcinoma DSA[J]. CT Theory and Applications, 2019, 28(3): 339-346. DOI: 10.15953/j.1004-4140.2019.28.03.07
    [3]MAO Mi-mi, LI Hong-jiang, FU Ai-yan, SHEN Ai-jun, SI Hai-feng, LI Chun-sun. Imaging Diagnosis and Differential Diagnosis of Fat-containing Primary Hepatocarcinoma[J]. CT Theory and Applications, 2014, 23(5): 821-828.
    [4]SONG Qiang, WANG Xiu-ling, HU Chun-feng. The Diagnostic Value and Type of Multi-slice Spiral CT Reconstruction in Small Renal Carcinomas[J]. CT Theory and Applications, 2011, 20(3): 351-356.
    [5]CHEN Xing-ming, LIANG Zhen-hua. The Diagnostic Value of 16-Slice Spiral CT Reconstruction in Talus Fractures[J]. CT Theory and Applications, 2010, 19(1): 87-92.
    [6]HU Shao-ping, SONG Huai, ZHOU Li-qiang. Application of the Spiral CT Scan with MPR Reconstruction in the Degenerative Lumbar Spinal Stenosis Clinical Diagnosis[J]. CT Theory and Applications, 2009, 18(3): 85-90.
    [7]LI Zhi-hong, GUO Jian-guo. Application Value of 3-D reconstruction with Spiral CT in Lumbar Trauma[J]. CT Theory and Applications, 2007, 16(2): 71-74.
    [8]XÜ Chun-lin, LIU Wei, ZHANG Xue-mei, ZHANG Yu-li, ZHU Wei-feng, JIANG Xing-hai, GUO Yan-zhang, WANG Hui. Clinical Application of 3-dimensional and Multiplane Reconstruction with Helical CT in Bone and Arthrosis trauma[J]. CT Theory and Applications, 2006, 15(3): 21-25.
    [9]ZHU Qing-xiao, TONG Jing, GUO Xin-hua, LI Xue. The Cerebralvascular Disease Diagnosis by using of 3D Reconstruction for MSCT Imaging[J]. CT Theory and Applications, 2005, 14(4): 21-23.
    [10]PENG Lei, XU Chun-lin, WEI Li-li. Spiral CT 3D Reconstructions for Pelvic Application in Bone Fracture[J]. CT Theory and Applications, 2002, 11(3): 39-41.

Catalog

    Article views (769) PDF downloads (1) Cited by()