ISSN 1004-4140
    CN 11-3017/P
    DONG Fang, XU Hong, HU Liang, FANG Li-yong, LI Bo-lin. Image Matching Algorithm Based on the Ellipse Fitting and Hausdorff Distance[J]. CT Theory and Applications, 2009, 18(1): 41-46.
    Citation: DONG Fang, XU Hong, HU Liang, FANG Li-yong, LI Bo-lin. Image Matching Algorithm Based on the Ellipse Fitting and Hausdorff Distance[J]. CT Theory and Applications, 2009, 18(1): 41-46.

    Image Matching Algorithm Based on the Ellipse Fitting and Hausdorff Distance

    More Information
    • Received Date: October 13, 2008
    • Available Online: December 14, 2022
    • Image matching is an important part of the field which is about reverse engineering CAD modeling,For the matching problem of CT images which contain bifurcation outline, ellipse-fitting was used to quantitative describe the completed shape and locating information for the series of discrete contour points,thus a elementary contour forest can be established. Speedy HD distance method was used to deal with the issue of branches to form a complete contour forest. Experimental results show that the algorithm to imatch images with good accuracy and real-time processing capability. It is useful to match CT images of rock heart, industry and medical.
    • Related Articles

      [1]LIU Yongliang, GUO Songlin, XU Chen, YIN Xiaotao. Estimation of Minimum Advanced Detection Distance for Tunnel Water Inrush and Mud Gushing Disasters[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.125
      [2]FAN Zhixuan, QUE Jiemin, WEI Cunfeng, LIU Baodong, WEI Biao. Research on Quadric Surface Fitting Algorithm Based on CT Data[J]. CT Theory and Applications, 2023, 32(1): 35-42. DOI: 10.15953/j.ctta.2022.040
      [3]LI Weiwei, XIONG Xin, MENG Aijun. Simulation Study on the Influence of the Distance between Two Boreholes on Seismic CT in Karst Detection[J]. CT Theory and Applications, 2022, 31(1): 33-45. DOI: 10.15953/j.1004-4140.2022.31.01.04
      [4]ZHAO Zhan, QIANG Jianke, ZHU Yuzhen. Study on Magnetic Analogy Fitting Inversion of Two-dimensional IP Data Using Central Gradient Array[J]. CT Theory and Applications, 2021, 30(6): 671-679. DOI: 10.15953/j.1004-4140.2021.30.06.02
      [5]DAI Qiu-sheng, YANG Lei, FAN Bo, XU Ru-xiang. Research on Focal Spot to Skin Distance of Small Mobile CT Scanner[J]. CT Theory and Applications, 2018, 27(6): 749-757. DOI: 10.15953/j.1004-4140.2018.27.06.08
      [6]CHEN Si, LI Jing, LI Shi-gen, LI Shou-tao, CHEN Yun-bin, ZHANG Xiao-li. A Registration and Evaluation Algorithm for the Calibration of Point Extraction Precision Based on ICT Equipment[J]. CT Theory and Applications, 2016, 25(6): 671-678. DOI: 10.15953/j.1004-4140.2016.25.06.07
      [7]YANG Fei, HAN Shuai, CHEN Jing, WANG Da-wei, CUI Shu-jun, GENG He-qun, LI Chuan-gui. Comparative Imaging Study of the Abdominal Aorta and its Branches with CT Enhanced Scanning and MR Enhanced Scanning[J]. CT Theory and Applications, 2016, 25(1): 79-84. DOI: 10.15953/j.1004-4140.2016.25.01.10
      [8]LÜ Zheng-dong, LIU Run-hua, LÜ Xin-rong. An Initial Contour Method for Active Contour Model[J]. CT Theory and Applications, 2012, 21(4): 605-614.
      [9]LI Shou-tao, CHEN Hao, ZHU Rui-hui, LI Xiao-mao. Application of CV Active Contour in Weld Defects Detection[J]. CT Theory and Applications, 2008, 17(4): 55-61.
      [10]LUO Guo-cheng, ZHAO Yong-jie. Heart Contour fitting in PET Image Using Mathematical Morphology and Spline Model[J]. CT Theory and Applications, 2002, 11(3): 1-6.