ISSN 1004-4140
CN 11-3017/P
AO Bo, ZHAO Xin-bo, ZHANG Ding-hua, XU Xia-gang, WANG Huan-shu. Relation Analysis between Volume Percent of Crack Defect and CT Number[J]. CT Theory and Applications, 2006, 15(2): 64-68.
Citation: AO Bo, ZHAO Xin-bo, ZHANG Ding-hua, XU Xia-gang, WANG Huan-shu. Relation Analysis between Volume Percent of Crack Defect and CT Number[J]. CT Theory and Applications, 2006, 15(2): 64-68.

Relation Analysis between Volume Percent of Crack Defect and CT Number

More Information
  • Received Date: December 07, 2005
  • Available Online: December 16, 2022
  • In this paper, from the linear representation of linear attenuation coefficient of mixture, density variations and CT number variations are induced by microcracks under stress, the formula between relative density variations and relative CT number variations is obtained without impurity. With further analyzing, a formula between relative volume percent of crack defect variations and relative CT number variations is obtained respectively, without impurity and with impurity, and we extend conclusion of impurity to impurities. All these lay a theoretical foundation for material fatigue life prediction by using CT.
  • Related Articles

    [1]LI Jingjing, ZHANG Li, LIU Mengwen, YANG Shouxin, LI Meng, JIANG Jiuming, YU Weijun. In Vivo Study of the Influence of CT Acquisition and Reconstruction Parameters on Chest CT Number[J]. CT Theory and Applications, 2023, 32(4): 480-486. DOI: 10.15953/j.ctta.2022.109
    [2]WANG Kun, DENG Jun, WEI Bingjun, LUO Zhipeng, YU Yang. A Simple Method to Determine Linear Attenuation Coefficients of Some Metal Materials Using 9MeV Industrial CT System[J]. CT Theory and Applications, 2019, 28(4): 439-446. DOI: 10.15953/j.1004-4140.2019.28.04.04
    [3]CHEN Yun-bin, WANG Yuan, LIU Qing-hua. A CT Number Conversion Method of Cone Beam CT[J]. CT Theory and Applications, 2015, 24(4): 553-561. DOI: 10.15953/j.1004-4140.2015.24.04.09
    [4]YU Guang-hui, LU Hong-yi, ZHU Min, WANG Xing-bo, WANG Hong-ling. Defects Location Method of CT Image Based on Similarity Transformation[J]. CT Theory and Applications, 2012, 21(1): 37-42.
    [5]AO Bo, ZHANG Xiao-hai, LI Chun-yang, DENG Cui-zhen. New Development of Fatigue Crack Propagation Analysis by High Resolution Computed Tomography[J]. CT Theory and Applications, 2010, 19(2): 35-41.
    [6]DAI Bin, ZHANG Wei-bin, TIAN Yong, TANG Xing. Analysis of Damaging Crack in Industrial CT Image of Energetic Material[J]. CT Theory and Applications, 2009, 18(4): 68-74.
    [7]YUAN Pei-xin, SUN Yan, CHEN Bo, JI Ge. Identify Defects of the Radiograph by Image Processing[J]. CT Theory and Applications, 2007, 16(1): 49-53.
    [8]XU Xia-gang, ZHAO Xin-bo, ZHANG Ding-hua, AO Bo. A Novel Testing Way for Collective Short Cracks by Industrial CT[J]. CT Theory and Applications, 2006, 15(1): 51-55.
    [9]AO Bo, ZHANG Ding-hua, ZHAO Xin-bo, XU Xia-gang. Theory Analysis of Crack Defect in CT Image[J]. CT Theory and Applications, 2005, 14(4): 10-16.
    [10]Ren Zhongqing, Xu Kai, Cheng Guangjun. Analysis of CT Features of Tired Tibia Fracture[J]. CT Theory and Applications, 2001, 10(3): 25-27.

Catalog

    Article views (740) PDF downloads (4) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint