  • Accurate coordinate of X-ray source is one of the key parameters in design of micro CT based on cone-beam X-ray system. The method of calculating the coordinate of X-ray source through a metallic ball model's 2-D projections is represented. It is based on micro source system which the source is counted as a particle under a certain amplification. Coordinate of the source could be calculated through projective lines. Avoiding the micro CT system is fixed, cone-beam reconstruction formulas with a nonstationary shift of X-ray source are represented. Model test are performed to show the effect after corrected for the shift of X-ray source.
  • Related Articles

    [1]XIANG Ronglin, ZHANG Li. Suppression Method for Cone-Beam CT Artifact Based on FDK Compensation and Dual-Source Weighting[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.222
    [2]BAI Juan-juan, YANG Yu-shuang, WANG Hai-peng. Spatial Registration of X-ray CT Projection Images[J]. CT Theory and Applications, 2016, 25(6): 661-670. DOI: 10.15953/j.1004-4140.2016.25.06.06
    [3]ZHANG Wen-kun, YAN Bin, CAI Ai-long, WEI Feng, DENG Lin, LI Lei. Selective Projection-rebin FDK Algorithm and its Efficient GPU Implementation[J]. CT Theory and Applications, 2015, 24(3): 383-392. DOI: 10.15953/j.1004-4140.2015.24.03.07
    [4]CHEN Yao, CHEN Ting, GUI Jian-bao, HU Zhan-li, Peter Z. WU, XIA Dan, ZHENG Hai-rong. Development of CNT Cathode Based X-ray Source and Imaging Technology[J]. CT Theory and Applications, 2013, 22(2): 363-372.
    [5]WANG Xian-chao, WANG Lin-yuan, LI Lei, YAN Bin. A Method for the Local Reconstruction of Flat Object Based on FDK Algorithm[J]. CT Theory and Applications, 2012, 21(1): 11-18.
    [6]CAI Dong-shan, SHI Cheng, XING Yu-xiang. Research on Theoretical Estimation of System Performance for 3D X-ray CT with FDK Reconstruction[J]. CT Theory and Applications, 2011, 20(4): 513-522.
    [7]HOU Ying, SUN Yi. Analysis on Application of Calibration Method for Cone-beam X-CT[J]. CT Theory and Applications, 2011, 20(2): 211-220.
    [8]WANG Chao, LI Jian-xin, WANG Da-hui, YAN Bin, LI Lei. Study on Acceleration of Cone-beam CT Image Reconstruction Based on DSP[J]. CT Theory and Applications, 2010, 19(4): 19-26.
    [9]XUE Zhen, ZHANG Bin, PAN Jin-xiao. A New Interpolation Method in the FDK Algorithm[J]. CT Theory and Applications, 2008, 17(3): 1-6.
    [10]TANG Jie, ZHANG Li, XING Yu-xiang, CHEN Zhi-qiang. Investigations into Error Reduction Based FDK Algorithms[J]. CT Theory and Applications, 2006, 15(1): 66-72.

Catalog

    Article views (601) PDF downloads (13) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return