ISSN 1004-4140
CN 11-3017/P
CHENG Ying, GUAN Ji-tian, JIN Yang, GUO Yue-lin, ZHANG Yuan-fang. 64-MSCT Coronary Angiography with Reduction Radiation Dose[J]. CT Theory and Applications, 2009, 18(3): 91-95.
Citation: CHENG Ying, GUAN Ji-tian, JIN Yang, GUO Yue-lin, ZHANG Yuan-fang. 64-MSCT Coronary Angiography with Reduction Radiation Dose[J]. CT Theory and Applications, 2009, 18(3): 91-95.

64-MSCT Coronary Angiography with Reduction Radiation Dose

More Information
  • Received Date: April 19, 2009
  • Available Online: December 14, 2022
  • Objective: To optimize the scan protocol,and reduce the radiation dose in coronary angiography with 64-MSCT.Methods: 60 patients were randomly divided into two groups,30 included in each group.Calcium score images were scanned by tube current of 430 mA and 80 mA;delayed time was detected by timing bolus and Smart Prep,respectively;Coronary angiography was performed using ECG-gated protocol without tube current modulation and that with tube current modulation.In all groups,the mean effective dose and signal noise of ratio were calculated and compared.Results: Mean ED of calcium score scan obviously decreased from 2.35 ±0.42 of 430 mA to 0.42 ±0.03 of 80 mA;that of the delayed time detection reduce increasingly from 1.39 ±0.14 by timing bolus to 0.13 ±0.04 by Smart Prep;and that of coronary angiography protocol reduced from 28.22 ±4.90 without tube current modulation to 21.14 ±1.54 with tube current modulation.There were significant differences between mean SNR by 430 mA with that by 80 mA in calcium score scans,but there were no significant differences between mean SNR without tube current modulation with that with tube current modulation.Conclusion: Using the scan protocol with tube current of 80 mA in calcium score,delayed time detection of Smart Prep,and ECG-gated tube current modulation,the radiation dose of coronary angiography with 64 MSCT could be reduced increasingly,and image quality achieves the diagnostic desire.
  • Related Articles

    [1]SHEN Xinnan, ZHOU Zhuohang, WANG Yiting, WANG Meiqi, YANG Yajing, ZHANG Zhiwei. The Impact of CARE kV Technology on Radiation Dose in Coronary Computed Tomography Angiography[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.336
    [2]FENG Mengya, LI Bing, WU Min, HUA Ting, TANG Guangyu. Application of New Iterative Reconstruction Algorithm Based on Artificial Intelligence and Low Tube Voltage in Reducing the Radiation Dose of Coronary CTA in Obese Patients[J]. CT Theory and Applications, 2023, 32(6): 777-782. DOI: 10.15953/j.ctta.2022.148
    [3]CHEN An, JIE Xue-qian, WANG Zheng, LI Yuan, ZHANG Hao, LI Nian-yun, MENG Jie. Value of Ultra-low Dose Coronary CT Angiography for Classification and Quantification of Coronary Stenosis[J]. CT Theory and Applications, 2018, 27(6): 701-707. DOI: 10.15953/j.1004-4140.2018.27.06.03
    [4]YU Wei-ping. Comparison of 64-slice Spiral CT and DSA in Evaluation of Patency after Coronary Stenting[J]. CT Theory and Applications, 2018, 27(5): 659-665. DOI: 10.15953/j.1004-4140.2018.27.05.13
    [5]TIAN Zhi-nan, LONG Shi-liang, ZHAO Yue, TAN Hong-wen. Feasibility of 80 kVp Ultra-low Dose Scan Protocol in Prospective Coronary CT Angiography[J]. CT Theory and Applications, 2017, 26(1): 99-106. DOI: 10.15953/j.1004-4140.2017.26.01.13
    [6]CAO Yu, ZHANG Yong-xian. Comparison of Multi-slice Spiral CT Imaging for Cardiac Coronary Arteries with Different Radiation Doses[J]. CT Theory and Applications, 2016, 25(1): 95-101. DOI: 10.15953/j.1004-4140.2016.25.01.12
    [7]WU De-hong, CHEN Shao-bo, FU Chuan-ming, XU Lin, CHEN Lun-gang, YU Guang-ju. Value of Automatic Tube Current Modulation Techniques to Reducing the Radiation Dose in CTU[J]. CT Theory and Applications, 2015, 24(2): 319-325. DOI: 10.15953/j.1004-4140.2015.24.02.18
    [8]ZHANG Chao-liang, GUAN Yu-bao, LIN Han-fei, CHEN Huai, ZENG Qing-si. Application Study of Low-dose 128-Slice Spiral CT Coronary Artery Angiography[J]. CT Theory and Applications, 2012, 21(4): 753-759.
    [9]LI Ruo-mei, WANG Si-wei, JIN Dan-dan. Low-dose CT Coronary Angiography with Status Quo of Tube Current and Voltage Parameters Optimization[J]. CT Theory and Applications, 2012, 21(3): 515-520.
    [10]GAO Jie, ZHANG Xue-feng. Low Dose 64-slice CT Coronary Angiography with Retrospective ECG Gating: A Clinical Study[J]. CT Theory and Applications, 2012, 21(1): 67-72.
  • Cited by

    Periodical cited type(4)

    1. 王毅,何岸苇,晁爱军. 糖尿病神经性骨关节病的诊治进展. 国际内分泌代谢杂志. 2024(02): 128-131 .
    2. 夏同敬,杨文江,夏天祥. 糖尿病足影像学表现分析. 影像研究与医学应用. 2023(18): 129-132 .
    3. 张钰欣,江红. 中药熏洗法在糖尿病足中的应用. 中医临床研究. 2022(16): 86-88 .
    4. 李梦龙,桑胜. MRI在糖尿病足(DF)溃疡诊断中的应用价值. 糖尿病新世界. 2021(16): 186-189 .

    Other cited types(0)

Catalog

    Article views (682) PDF downloads (4) Cited by(4)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return