Analysis of Safety Measure of Using Pressure Injector During Enhanced CT & MR Scanning

More Information
  • Available Online: December 16, 2022
  • We analysed retrospectively the cases who occur contrast leakage from blood vessels for using pressure injector during enhanced CT and MR scan from January to November, 2001. Because there are relative great pressure, high speed with high pressure injector, so it is easy to result in contrast leakage from blood vessels when injecting. It is preventive through standard operation, chose right puncture position, the gauge of injector needle and so on.
  • Related Articles

    [1]WANG Yongsheng, WANG Chensi, LU Haoyu, TIAN Xiangbao, ZHUANG Qixin. Study on the Value of Individualized Contrast Agent Injection Scheme in Improving the Biosafety of Pulmonary Artery CTA[J]. CT Theory and Applications, 2021, 30(6): 777-783. DOI: 10.15953/j.1004-4140.2021.30.06.14
    [2]CUI Zhaorui, SHI Zhangzheng, MO Xukai. Meta Analysis of Adenosine Antagonists in the Prevention of Contrast Induced Nephropathy[J]. CT Theory and Applications, 2020, 29(2): 211-218. DOI: 10.15953/j.1004-4140.2020.29.02.12
    [3]CAO Hong-wei, XING Yuan-yuan, CHOU Heng-zhi, ZHANG Dan, CAO Zhen-dong, WAN Li-ye, WANG Sheng-lin. The Effect of Contrast Medium Injection Rate on the Image Quality of Inferior Vena Cava Direct CTV[J]. CT Theory and Applications, 2017, 26(6): 775-782. DOI: 10.15953/j.1004-4140.2017.26.06.15
    [4]ZHAO De-ming, GU Xiao-ying, PEI Lin-hui, CHEN Jie, ZHU Hong-gen, SUN Yong-kang. Spiral CT Study on Intravenous Contrast-enhanced Inspection Parameters of the Lower Extremities[J]. CT Theory and Applications, 2012, 21(4): 747-752.
    [5]FAN Xu, GUO Zhi-rui, CAO Min, ZHOU Xue-feng, GU Ning. Contrast Agents for Computed Tomography Based on Gold Nanoparticles[J]. CT Theory and Applications, 2009, 18(4): 15-25.
    [6]GAO Wen-jie, HUO Jian-wei, DOU Xiu-mei, LI Xia. Ulrich Contrast Medium Injector in 64 Row of Spiral CT Inspection Application[J]. CT Theory and Applications, 2006, 15(3): 50-52.
    [7]ZHANG Yuan-fang, LIU Guo-rui, FANG Wen-hui, GUO Yue-lin, LI Yang-kang. The Application of High Pressure Injector in CT Contrast Enhancement[J]. CT Theory and Applications, 2004, 13(2): 46-50.
    [8]CHEN Wei-chang, CHEN Zhi-hua, ZHAO Tian-de, WANG Zi-qiang. Improvement of CT Contrast (Density) Resolution By Dual Photons Absorption Method[J]. CT Theory and Applications, 2002, 11(4): 5-8.
    [9]Li Ronghuan, Li Jinzhi, Li Xinhua, Zhang Haining, Cui Wenguo. Prevention and Management of Side-effect of Contrast Media in CT Enhancemant Scan[J]. CT Theory and Applications, 2000, 9(3): 20-22.
    [10]Liu Jianxin, Jia Shaotian, Deng Gang, Wang Jun, Chang Xin, Tong Shuangli. Comparison of Four MR Scanning Sequence for Liver[J]. CT Theory and Applications, 2000, 9(2): 33-36.