ISSN 1004-4140
CN 11-3017/P
Yang Xuhai, Zhang Xiaochun. The Mathematical Definition Of Original Digital Image And the Abstraction of Stripe Noise[J]. CT Theory and Applications, 2001, 10(3): 42-46.
Citation: Yang Xuhai, Zhang Xiaochun. The Mathematical Definition Of Original Digital Image And the Abstraction of Stripe Noise[J]. CT Theory and Applications, 2001, 10(3): 42-46.

The Mathematical Definition Of Original Digital Image And the Abstraction of Stripe Noise

More Information
  • Received Date: June 17, 2001
  • Available Online: December 28, 2022
  • This paper tries to give the mathematical definition of original digital image which makes it easier to carry out the reconstruction and process of the image, it also analyzes the reason why there remains the stripe noise, and shows the ways of how to take it off .As a result, it solves the problem of Abstracting rocks fractures using CBIL data.
  • Related Articles

    [1]XIA Xinru, JIANG Guoming, ZHAO Dapeng. Crustal Velocity Structure of the Middle-Southern Segment of the Tanlu Fault Zone (China) and its Correlation with the Seismic Activity in the Region[J]. CT Theory and Applications, 2025, 34(2): 163-174. DOI: 10.15953/j.ctta.2024.257
    [2]TANG Shaojie, YUAN Tengqi, LI Siyu, LI Shubo, ZHANG Ting, WEI Qiuyue, YAO Hongping. Few-shot Periodic Video Image Segmentation Based on LSTM and Cross-attention Mechanism[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.033
    [3]DING Ling, ZHANG Yuzhong, E Linning. Diagnosis of Acute Active Gastrointestinal Bleeding by Multi-phase Contrast-enhanced Computed Tomography: A Clinical Case Analysis[J]. CT Theory and Applications, 2023, 32(6): 807-814. DOI: 10.15953/j.ctta.2023.065
    [4]WANG Yu’ang, GAO Hewei, ZHANG Li. Removal of Gridline Artifacts in Cone-beam CT Based on Wavelet Transform[J]. CT Theory and Applications, 2023, 32(4): 437-449. DOI: 10.15953/j.ctta.2022.233
    [5]SUN Peipei, LIU Shurong, HOU Xuejing, JIANG Lijie, WANG Qiang. Imaging Features of High-resolution CT with Active Tuberculosis and Diagnostic Value of Their Combination with T-SPOT.TB and TB-Ab[J]. CT Theory and Applications, 2021, 30(3): 331-339. DOI: 10.15953/j.1004-4140.2021.30.03.06
    [6]GAO Yun, GUAN Xueni, RONG Lan, ZHOU Lei, LIANG Zonghui. Diagnostic Value of CT Value of Creeping Fat around Intestinal Tube for Crohn's Activity[J]. CT Theory and Applications, 2019, 28(4): 477-484. DOI: 10.15953/j.1004-4140.2019.28.04.09
    [7]ZHAO Chang-hong, LIU Ai-shi, HAO Fen-e. 320-detector Row CT Double Low-dose CTCA with Manual Bolus Tracking: A Feasible Study[J]. CT Theory and Applications, 2018, 27(5): 583-591. DOI: 10.15953/j.1004-4140.2018.27.05.04
    [8]GUO Hai-dong, ZHAO Sheng, GUO Xiu-ling, LIU Ai-shi. A Feasibility Study on Coronary Angiography with Flash Technique of Dual-source Computed Tomography by Double Low Technical and Manual Trigger Scanning[J]. CT Theory and Applications, 2016, 25(6): 639-646. DOI: 10.15953/j.1004-4140.2016.25.06.03
    [9]YE Wen-wei, ZHANG Yan-hong, LI Zhong-rong, GUO Tian-chang, CHENG Wei-guang, CHEN Yi-bin, LIU Qin. Correlation between MSCTE Evaluation of Crohn's Disease Activity Index and the Harvey-Bradshaw Index[J]. CT Theory and Applications, 2016, 25(3): 349-354. DOI: 10.15953/j.1004-4140.2016.25.03.11
    [10]DONG Fang, HU Liang, LI Bo-lin, LI Ming, CHEN Hao, WANG Yuan, ZHANG Cheng-xin, XU Zhou. Contour Data Denoise Based on Inter-Scale Correlations of Contourlet Transform[J]. CT Theory and Applications, 2008, 17(4): 62-66.

Catalog

    Article views (607) PDF downloads (4) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return