  • Objective TO measure the width of disk-fiavum ligamentum spase(DFLS) and evaluate it's value in diagnose of herniation of intervertibral disk. Materials and Methods The image of CT in lumbar intervertibral disk of 200 cases were retrospectively analyzed; and the shapes of L3-S1 disk, the width of flavum ligmenta at each side and that of DFLS were recorded.. The relation of the restructions and parameters to DFLS stenosis and the compressed lumbar nerve roots shown in CT were analyzed. Results The herniation or bluging of intervertibral disk were found in l96 level; 78 flava ligments width >5mm; 172 of 200 cases of mean width DFLS (3.60.8)mm. Conclusion The DFLS£5mm can be diagnosed stenosis. The main causes of stenosis are herniation or bluging of intervertibral disk, flava ligamen thicker. It can be used as a valuable criterion diagnosing lumbar nerve boot compression in CT study.
  • Related Articles

    [1]ZHANG Wei, LI Cheng-feng, LIU Chang-ling, HU Gao-wei, MENG Qing-guo, HUANG Xiang-dong, ZHAO Shi-jun. Identification Technology of the CT Images for Distinguishing the Boundary Condition of Methane Hydrate in Porous Media[J]. CT Theory and Applications, 2016, 25(1): 13-22. DOI: 10.15953/j.1004-4140.2016.25.01.02
    [2]ZHENG Li-jun, LIU Yi-bao, WANG Ai-xing. Simulation of High Energy X-CT Detector Based on Gas Electron Multiplier by MCNP Program[J]. CT Theory and Applications, 2014, 23(3): 435-442.
    [3]HOU Ying, SUN Yi. Analysis on Application of Calibration Method for Cone-beam X-CT[J]. CT Theory and Applications, 2011, 20(2): 211-220.
    [4]LI Qing-liang, YAN Bin, SUN Hong-sheng, LI Lei, ZHANG Feng. Review of Metal Artifacts Correction Methods on X-ray Computed Tomography[J]. CT Theory and Applications, 2011, 20(1): 131-140.
    [5]ZHANG Feng, YAN Bin, LI Jian-xin, LI Lei, BAO Shang-lian. Review of Scatter Correction on X-Ray Industrial Computed Tomography[J]. CT Theory and Applications, 2009, 18(4): 34-43.
    [6]HU Shao-ping, SONG Huai, ZHOU Li-qiang. Application of the Spiral CT Scan with MPR Reconstruction in the Degenerative Lumbar Spinal Stenosis Clinical Diagnosis[J]. CT Theory and Applications, 2009, 18(3): 85-90.
    [7]XU Hai-jun, WEI Dong-bo, FU Jian, ZHANG Li-kai, DAI Xiu-bin. Fast Computation of 3D Radon Transform Via a Geometrical Method[J]. CT Theory and Applications, 2008, 17(2): 1-7.
    [8]XU Chun-lin, ZHANG Xue-mei, PENG Lei, GUO Yan-zhang, LIU Wei, WANG Jian-guo, ZHU Wei-feng. An Analysis of Clinical and CT of Peripheral Lumbar Spinal Stenosis Compression Lumbar Intervertebral Vein[J]. CT Theory and Applications, 2004, 13(4): 31-35.
    [9]HAN Xiao-mian, TIAN Ben-xiang, YUAN Ling-jin. A Comparative Study of X-ray and CT in Hydrothorax[J]. CT Theory and Applications, 2003, 12(3): 34-35.
    [10]HAN Xiao-mian, GU Ye-qiang, YUAN Ling-jin. Contrast Research of The Mediastinal Part Tumor's X-ray and CT[J]. CT Theory and Applications, 2002, 11(4): 27-29.
  • Cited by

    Periodical cited type(5)

    1. 朱春梅,陈步东,靳二虎. 尘肺病影像学诊断研究进展. 临床和实验医学杂志. 2019(06): 668-670 .
    2. 温小庭,黄忠,陈伟,陈竞雄,何茂贤,陈伯平. 尘肺病患者DR和肺功能检查结果分析. 深圳中西医结合杂志. 2019(06): 85-86 .
    3. 周建中,刘贵喜,曹子文,陈丽琨. 低剂量螺旋CT扫描对尘肺小阴影肺结节的诊断价值分析. 临床医学. 2019(06): 19-21 .
    4. 梁振华,方挺松,黄钰坚,潘邦盛,李均洪. 低剂量CT扫描技术在青少年骶髂关节中的应用. CT理论与应用研究. 2018(01): 71-76 . 本站查看
    5. 吴洁,韩景军. 多层(64层)CT低剂量双相扫描肺密度对评价COPD患者肺功能的应用分析. 影像研究与医学应用. 2018(16): 173-174 .

    Other cited types(1)

Catalog

    Article views (757) PDF downloads (5) Cited by(6)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return