ISSN 1004-4140
CN 11-3017/P
Shi Xuetao, Dong Xiuzhen, You Fusheng, Qin Mingxin, Tang Mengxing, Liu Ruigang, Fu Feng, Wu Xiaoming. A Dais Acquisition System for Multi-frequency EIT based on Frequency Mixing and Sweeping Technique[J]. CT Theory and Applications, 2001, 10(2): 47-51.
Citation: Shi Xuetao, Dong Xiuzhen, You Fusheng, Qin Mingxin, Tang Mengxing, Liu Ruigang, Fu Feng, Wu Xiaoming. A Dais Acquisition System for Multi-frequency EIT based on Frequency Mixing and Sweeping Technique[J]. CT Theory and Applications, 2001, 10(2): 47-51.

A Dais Acquisition System for Multi-frequency EIT based on Frequency Mixing and Sweeping Technique

Funds: 

National Natural Science Foundation (NSFC39870217)

More Information
  • Received Date: May 09, 2001
  • Available Online: December 28, 2022
  • A new 32-electrode data acquisition system for multi-frequency EIT has been designed. In this system, sweeping frequency combined with mixing frequency technique is employed. With its four working modes and control programs, it can collect impedance information at four different frequencies simultaneously from 1.6kHz to 380kHz in order to demodulate the signal with more than one frequency in a single set of measurement, a new digital demodulation method. which has the advantages of high calculation speed and high precision, has been developed and named by us as 'orthogonal sequential digital demodulation'. For a signal with 'n' components of frequencies and sampling N points per period, using this method. the total needed operations is 2nN multiplication and 2n(N-1) addition operations, and the signal-to-noise ratio can be improved by (N/2)0.5times.
  • Related Articles

    [1]ZHANG Bo, QIU Ao, XIA Yuan, XIAO Peng, XIE Qingguo. All-Digital Positron Emission Tomography Industry Ecology[J]. CT Theory and Applications, 2024, 33(4): 459-470. DOI: 10.15953/j.ctta.2024.018
    [2]LI Xinyu, LIU Yu, CHENG Ran, XIE Qingguo, XIAO Peng. Innovative Application-Specific All-Digital PET Systems[J]. CT Theory and Applications, 2024, 33(4): 448-458. DOI: 10.15953/j.ctta.2024.012
    [3]QIU Ao, XIE Qingguo. Multi-Voltage Threshold Digitization Method[J]. CT Theory and Applications, 2024, 33(4): 393-403. DOI: 10.15953/j.ctta.2024.011
    [4]YANG Min, SUN Chen-xi, XING Chun-xiang, LIU Yong-zhan. Construction of a Teaching and Experimental Platform of Digital Radiography and Industrial Computed Tomography[J]. CT Theory and Applications, 2014, 23(2): 347-356.
    [5]ZHANG Jun-sheng, WANG Ming-quan, GUO Yong-liang, CHEN Zhi-qiang. Analysis of X-ray Digital Imaging System Resolution[J]. CT Theory and Applications, 2011, 20(2): 227-234.
    [6]REN Peng-ju, JIANG Hua, LI Lei, YAN Bin, LIU Jian-dong. The Realization of the High-Speed Data Acquisition of the CBCT System Based on LVDS Technology[J]. CT Theory and Applications, 2009, 18(1): 76-82.
    [7]DAN Guo, GE Yi-lin, CHEN Si-ping, TAO Du-chun. Design of a High-Speed Multi-Channel Data Acquisition System with PGA of the Medical CT[J]. CT Theory and Applications, 2005, 14(1): 37-41.
    [8]ZHANG Hui-tao, ZHANG Peng, SONG Li-ming. Fast Implementation of Direct Demodulation Imaging Method for HXMT[J]. CT Theory and Applications, 2005, 14(1): 17-23.
    [9]TANG Bin, LI Xi-an, ZHANG Song-bao, XIA Ming, XIANG Dong, WEI Biao. Thermal Neutron Digital Imaging System Based Cooled CCD[J]. CT Theory and Applications, 2004, 13(4): 20-25.
    [10]XI Yan-ping. Digitized X-ray Imaging Technique[J]. CT Theory and Applications, 2004, 13(2): 30-32.

Catalog

    Article views (570) PDF downloads (5) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return