The Comparison Study Between CT & MRI

More Information
  • Received Date: November 30, 1999
  • Available Online: December 28, 2022
  • Both CT and MRI are the most widely used clinical imaging facilities nowadays. This article is invited to give a significant and valuable comparison between CT and MRI in many aspects, such as imaging principles, performances, demand, features, parameters, sensibilities, securities, nature of signals, signals standards, theories of reconstruction methods, etc. It also traces back to the history resemblance of these two methods, and expounds that the sole development of these two mathematical methods (Radon Transform & Fourier Transform) roots in the distinct difference between CT and MR signals. Signal of MR is in time domain and signal of X-ray is in space domain. It is also pointed out that the mathematical foundation of PET, SPECT, OCT, UCT are of the same clan, except the MRI.
  • Related Articles

    [1]WANG Lin, QU Gangrong. The Numerical Solution of the Radon Transform Along the Circular Curve[J]. CT Theory and Applications, 2020, 29(3): 329-336. DOI: 10.15953/j.1004-4140.2020.29.03.09
    [2]GONG Shu, REN Qin-qin, WANG Min-ling. Application of Parabolic Radon Transform in the Suppression of Multiple Seismic Wave[J]. CT Theory and Applications, 2017, 26(2): 165-176. DOI: 10.15953/j.1004-4140.2017.26.02.05
    [3]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [4]WANG Li-xin, HUANG Guang-tan, ZHANG Bin-bin, ZHU Wen-bo, ZHANG Jun-hua. Suppressing Method Study and Application of Seismic Scattered Wave Based on Local Hyperbolic Radon Transform[J]. CT Theory and Applications, 2014, 23(1): 27-36.
    [5]XUE Hui, ZHANG Li, LIU Yi-nong. Overview of Nonuniform Fast Fourier Transformation[J]. CT Theory and Applications, 2010, 19(3): 33-46.
    [6]XU Hai-jun, WEI Dong-bo, FU Jian, ZHANG Li-kai, DAI Xiu-bin. Fast Computation of 3D Radon Transform Via a Geometrical Method[J]. CT Theory and Applications, 2008, 17(2): 1-7.
    [7]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
    [8]Zhang Tie, Li Jiandong, Li Changjun, Zheng Quanlu, Zhang Jiwu. Improved Fourier Algorithm of CT Imaging and Experiment[J]. CT Theory and Applications, 2000, 9(4): 7-11.
    [9]Zhang Tie, Yan Jiabin. The Error Analysis of Improved Fourier Algorithm for Solving Radon Transform[J]. CT Theory and Applications, 2000, 9(1): 12-16.
    [10]Wang Jinping. The Inversion Formula of Radon Transform in R2[J]. CT Theory and Applications, 2000, 9(1): 8-11.

Catalog

    Article views (2342) PDF downloads (14) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return