ISSN 1004-4140
CN 11-3017/P
Li Zhangming. Application of Ground Penetrating Radar in Three Gorges Project[J]. CT Theory and Applications, 2000, 9(3): 41-46.
Citation: Li Zhangming. Application of Ground Penetrating Radar in Three Gorges Project[J]. CT Theory and Applications, 2000, 9(3): 41-46.

Application of Ground Penetrating Radar in Three Gorges Project

More Information
  • Received Date: May 17, 2000
  • Available Online: December 28, 2022
  • During the Three Gorges Projct,many complicated engineering and geological problens are met,high-resolution harmless detecting method is needed to find bured geological defect or engineering quality problems,to guarantee the project schedule and engineering quality. Georadar is applied in detecting the extension of inhomogeneous weatheriag of granite, mapping the extension and geomery of large faults and weathering alternative layers, checking the enginecring quality of expresses. 3 case histories are introduced.The detecting results are consistent to the real situations. The application effects are obvious.
  • Related Articles

    [1]LI Xiu, LUO Hao, DENG Fei, ZHENG Xingjun, ZHOU Taosheng, ZHENG Jia. Study on Nondestructive Testing of Source Factors of Tunnel Arch Quality[J]. CT Theory and Applications, 2025, 34(2): 245-254. DOI: 10.15953/j.ctta.2023.204
    [2]GAO Nanlin, WANG Xinwen, XUE Liya, WANG Jie, DING Jinxiang. Correlation between Dual-Phase Quantitative Parameters from Dual-Layer Spectral Detector Computed Tomography and Ki-67 Expression in Non-Small Cell Lung Cancer[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.299
    [3]WANG Yongsheng, YANG Leiqing, YANG Yifan, PEI Qingxia, WANG Chensi, LU Mengyun, HE Junlin, CHEN Wenjing, TIAN Xiangbao. The Effect of Different Trigger Thresholds on the Quality of Pulmonary Artery CT Angiography Images[J]. CT Theory and Applications, 2024, 33(2): 175-181. DOI: 10.15953/j.ctta.2023.121
    [4]LIU Fangtao, LIU Heshi, CHEN Yong, JIANG Jiang, WANG Lingyun, DONG Haipeng, ZHANG Yong, ZHANG Xuan, KONG Deyan, CHANG Rui. Image Quality Assessment for Deep Learning Image Reconstruction Algorithm: A Phantom Study[J]. CT Theory and Applications, 2022, 31(3): 351-356. DOI: 10.15953/j.ctta.2021.061
    [5]FANG Shu, CHEN Linyu, CHEN Yong, DONG Haipeng, WANG Lan, MIN Jihua. Phantom Study on the Influence of CT Model and Tube Voltage on Image Quality[J]. CT Theory and Applications, 2022, 31(3): 345-350. DOI: 10.15953/j.ctta.2021.042
    [6]PAN Jishun, SUN Kaixuan, ZHANG Niu, LI Penghui. Non-SIRT Engineering Seismic Wave CT Technology[J]. CT Theory and Applications, 2020, 29(2): 119-127. DOI: 10.15953/j.1004-4140.2020.29.02.01
    [7]ZHAO Li-qin, HE Wen, LI Jian-ying, CHEN Jiang-hong, HU Zhi-hai, ZHANG Rui. The Pilot Study of Energy Spectral CT on the Image Quality of CT Portal Venography[J]. CT Theory and Applications, 2011, 20(3): 383-390.
    [8]SHAO Jun-ming, XU Xiao-dong, KONG Jun. Research on CT System Imaging Quality[J]. CT Theory and Applications, 2006, 15(3): 61-67.
    [9]WANG Yan-fang, QUE Jie-min, LIU Li, ZENG Gang. A Software of Reverse Engineering Based on Industrial CT[J]. CT Theory and Applications, 2004, 13(3): 39-42.
    [10]ZHU Tao, FENG Rui, HAO Jin-qi. Groundwater and Faults in Resistivity Images[J]. CT Theory and Applications, 2002, 11(4): 43-49.

Catalog

    Article views (685) PDF downloads (6) Cited by()