Tian Maoliang, Xu Wenzhi, Zhang Ping. The Computer System Design for the CD50BG Industrial Computerized Tomography[J]. CT Theory and Applications, 2000, 9(2): 41-45.
Citation: Tian Maoliang, Xu Wenzhi, Zhang Ping. The Computer System Design for the CD50BG Industrial Computerized Tomography[J]. CT Theory and Applications, 2000, 9(2): 41-45.

The Computer System Design for the CD50BG Industrial Computerized Tomography

More Information
  • Received Date: July 02, 1999
  • Available Online: December 28, 2022
  • This paper gives a design of computer system for the low price industria computedtomography . It also discusses the design of data collection system and single step electromotor driving in the CD50BG industrial computerized tomography in detail.
  • Related Articles

    [1]YANG Xiong-bin, LIU Peng-hao, ZHUANG Kai, LI Ting, QIN Xiu-bo, XIE Guang. Designation & Adjustment of the Control Plat and Data Collection System of Crystal Orientation Instrument[J]. CT Theory and Applications, 2018, 27(4): 477-484. DOI: 10.15953/j.1004-4140.2018.27.04.07
    [2]HUO Mei-chun, LI Hao, ZHANG Yan-ming, WU Jian-yi, MO Yang, CAO Qin-qin. The Implementation of a Conveying System Based on Synchronous Belt Drive in CT Security Equipment[J]. CT Theory and Applications, 2012, 21(3): 443-448.
    [3]CHEN Si, CHEN Hao, LI Shou-tao. A Kind of NURBS Surface Reconstruction Method for Industrial CT Cloud Data[J]. CT Theory and Applications, 2011, 20(1): 11-20.
    [4]REN Peng-ju, JIANG Hua, LI Lei, YAN Bin, LIU Jian-dong. The Realization of the High-Speed Data Acquisition of the CBCT System Based on LVDS Technology[J]. CT Theory and Applications, 2009, 18(1): 76-82.
    [5]WANG Yuan, XU Zhou, CHEN Hao, LI Ming, JIN Xiao, HU He-ping, GAN Kong-yin, ZHANG Cheng-xin, LU He-ping. Data acquiring System for High Energy Industrial CT Based on Flat-Panel Detector[J]. CT Theory and Applications, 2006, 15(3): 53-56.
    [6]LANG Dong-jiang, WANG Wei-min, SHANG Gen-hua. Visualization of Combination Corefloods and Oil driving with Aid of NMR Imaging[J]. CT Theory and Applications, 2006, 15(3): 11-16.
    [7]XU Xia-gang, ZHAO Xin-bo, ZHANG Ding-hua, AO Bo. A Novel Testing Way for Collective Short Cracks by Industrial CT[J]. CT Theory and Applications, 2006, 15(1): 51-55.
    [8]SHENG Qiang, SHI Xiao-le, LIU Wei-fu, XING Yi-liang. 3D imaging CT and multi-phase Driving -substitute Analytical System for rock-core and Oil[J]. CT Theory and Applications, 2005, 14(3): 8-12.
    [9]DAN Guo, GE Yi-lin, CHEN Si-ping, TAO Du-chun. Design of a High-Speed Multi-Channel Data Acquisition System with PGA of the Medical CT[J]. CT Theory and Applications, 2005, 14(1): 37-41.
    [10]Zhang Ping, Xu Wenzhi. Data Collect System Design and Realize for CD-300BG type Industry Computerized Tomography[J]. CT Theory and Applications, 2000, 9(1): 17-21.