ISSN 1004-4140
CN 11-3017/P
HUANG Yin-ping, SHEN Bi-xian, CHEN Sheng-ji, ZHOU Na, BAO Lian, CHEN Li-xing. The Research of Comparision between Dual Source CT Air Enema Intestinal Examination and Capsule Endoscopy Small Bowel Examination[J]. CT Theory and Applications, 2010, 19(3): 123-129.
Citation: HUANG Yin-ping, SHEN Bi-xian, CHEN Sheng-ji, ZHOU Na, BAO Lian, CHEN Li-xing. The Research of Comparision between Dual Source CT Air Enema Intestinal Examination and Capsule Endoscopy Small Bowel Examination[J]. CT Theory and Applications, 2010, 19(3): 123-129.

The Research of Comparision between Dual Source CT Air Enema Intestinal Examination and Capsule Endoscopy Small Bowel Examination

More Information
  • Received Date: April 24, 2010
  • Available Online: December 12, 2022
  • Objective: To evaluate the value of the dual source CT air enema intestinal examination in the diagnosis of small bowel diseases.Methods: 15 patients with suspected small bowel diseases underwent dual-source CT inspection before or after the capsule endoscopy within 3 days.Among them,8 males and 7 females,the oldest 42 years old,the youngest 23 years old.The major symptoms were abdominal pain in 10 cases,blood and pus stool in 4 cases,1 case of unexplained weight loss,the longest duration was 4 years and the shortest was 1 month.Results: Capsule endoscopy showed normal in 8 cases,dual-source CT examination were no exception.Dual-source CT diagnosed Crohn diseases in 4 cases,clinical diagnosis with capsule endoscopy were the same.Capsule endoscopy suspected tumors in 3 cases,but dual-source CT examination only found two positive cases,with diagnosis of benign and malignant,of which,confirmed by pathology,1 was jejunum stromal tumors,another was ileal adenocarcinoma.Only one case with 3cm size was suspected the tumor in capsule endoscopy,but in dual source CT was normal.Combined with MRI,and clinical history,the issue was proved to be false positive.Conclusion Dual source CT air enema intestinal examination could not only show the scope of the relationship with adjacent structures,and identify clinical inflammation and cancer lesions,and make the tumor differentiation of benign and malignant lesions.The examinations are also valuable for capsule endoscopy to confirm localization and scope of lesions,and rule out false positive.
  • Related Articles

    [1]XU Chi, SHEN Yuwen, SHI Yiqiu, LI Ming, LIU Kefu. Research Progress on Radiology in Spread Through Air Space in Lung Cancer[J]. CT Theory and Applications, 2024, 33(3): 371-376. DOI: 10.15953/j.ctta.2023.140
    [2]BA Wenjuan, ZHU Yanlin, WEI Mei, YIN Ke. Advances in the Preoperative Prediction of the Spread of Lung Adenocarcinoma Through Air Spaces Using CT Features[J]. CT Theory and Applications, 2024, 33(1): 91-96. DOI: 10.15953/j.ctta.2022.236
    [3]DENG Xiaolin, XIE Hui, QU Yalin, WU Shaoquan, ZHOU Bangjian, YANG Zhengbin, FENG Lian, WANG Min. The Value of Optimal Monochromatic Spectral CT Imaging in Gastric Variceal Bleeding before Endoscopic Treatment[J]. CT Theory and Applications, 2021, 30(5): 603-609. DOI: 10.15953/j.1004-4140.2021.30.05.08
    [4]ZHU Lijuan, ZHU Xiaoming, SONG Dongdong, ZHANG Qing, WU Fei. AI Detection Efficiency of Pulmonary Nodules Under Dual-source CT with Different Tube Voltages[J]. CT Theory and Applications, 2021, 30(4): 495-502. DOI: 10.15953/j.1004-4140.2021.30.04.10
    [5]ZHU Chunmei, CHEN Budong, XU Yan, HE Wen, TANG Hongqu, JIN Erhu. Analysis of Correlation between CT Features of Phase III Pneumoconiosis and Silica Content in the Lungs[J]. CT Theory and Applications, 2019, 28(5): 569-576. DOI: 10.15953/j.1004-4140.2019.28.05.06
    [6]ZHANG Xiao-qin, LIAO Jian, WANG Min, ZHANG Kai, DONG Yu-qing, YUN Feng. The Control Study of Dual Source CT Dual Energy Lung Perfusion Imaging and CTPA with Experimental Acute Pulmonary Embolism Model[J]. CT Theory and Applications, 2017, 26(2): 147-156. DOI: 10.15953/j.1004-4140.2017.26.02.03
    [7]LI Jing, LIU Huai-jun, GUO Qing-le, LIU Jing-wang, WANG Jun-qi. Multi-slice Spiral CT Virtual Endoscopy in Diagnosis of Adult Bicuspid Aortic Valve Deformity[J]. CT Theory and Applications, 2017, 26(1): 107-114. DOI: 10.15953/j.1004-4140.2017.26.01.14
    [8]ZHANG Hua, HUANG Kui-dong, SHI Yi-kai, LI Ming-jun. Ring Artifact Correction Method Based on Air Scan for Cone-beam CT[J]. CT Theory and Applications, 2012, 21(2): 247-254.
    [9]XIANG Zi-yun, ZHU Ping-xian. Clinical Application of Multi-Slice CT Virtual Intravascular Endoscopy in Diagnosis of Arteriosclerosis[J]. CT Theory and Applications, 2004, 13(2): 37-42.
    [10]Liu Ying, Bi Chunlong, Ge Huiyu. Clinical Application of Helical CT Virtual Endoscopy of Stomach[J]. CT Theory and Applications, 2000, 9(2): 31-32.
  • Cited by

    Periodical cited type(2)

    1. 于明羽,吴遵红,谭凯,彭代诚,熊绚兮,刘江平. 隧道环境下频率域声波全波形反演优化方法对比. 工程地球物理学报. 2021(01): 1-13 .
    2. 高原,顾文杰,丁雨恒,彭晖,陈泊宇,顾雯轩. 异构集群中CPU与GPU协同调度算法的设计与实现. 计算机工程与设计. 2020(02): 592-601 .

    Other cited types(8)

Catalog

    Article views (1310) PDF downloads (4) Cited by(10)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return