ISSN 1004-4140
CN 11-3017/P
WU Kun, PAN Jin-xiao. The Projection Ordering Scheme of Three-dimensional Cone-beam for ART[J]. CT Theory and Applications, 2010, 19(4): 61-70.
Citation: WU Kun, PAN Jin-xiao. The Projection Ordering Scheme of Three-dimensional Cone-beam for ART[J]. CT Theory and Applications, 2010, 19(4): 61-70.

The Projection Ordering Scheme of Three-dimensional Cone-beam for ART

More Information
  • Received Date: July 05, 2010
  • Available Online: December 12, 2022
  • The order of the applied projections in Algebraic Reconstruction Technique(ART) has a great effect on speed of convergence and accuracy in reconstructed image.In 3D cone-beam ART,some schemes of the sort of the projection sequence are compared in the paper.The schemes are listed below:Sequence Access(SAS),Multilevel(MLS),Prime Number Decomposition(PND),and Weighted Distance(WDS).The experiment results got by simulation experiment show that the speed of convergence on which reconstructed image by MLS,PND and WDS is more quick than by SAS,and the WDS is the best one in three sort schemes.
  • Related Articles

    [1]GUO Qiao, YAO Xufeng. Progress of Material Decomposition Algorithms in Dual-energy CT Imaging[J]. CT Theory and Applications, 2023, 32(1): 139-146. DOI: 10.15953/j.ctta.2021.067
    [2]WANG Chongxu, CHEN Ping, PAN Jinxiao, LIU Bin. Research on Material Decomposition of Dual-energy CT Image Based on Iterative Residual Network[J]. CT Theory and Applications, 2022, 31(1): 47-54. DOI: 10.15953/j.1004-4140.2022.31.01.05
    [3]LIU Ze-qun, SUN Mei-yu, LIU Ai-lian, HAN Zheng. Influence of the Size of Regions of Interest on CT Value and Material Decomposition Measurement in Water Phantom by Single-source Dual Energy CT[J]. CT Theory and Applications, 2016, 25(2): 129-134. DOI: 10.15953/j.1004-4140.2016.25.02.01
    [4]WANG Lin-yuan, TONG Li, YAN Bin, HU Guo-en. A Method for Image Bipolar Detail Decomposition Based on the TV/L2 Model[J]. CT Theory and Applications, 2013, 22(1): 75-83.
    [5]LI Chen, LIU Jie. An Automatic Image Sorting Algorithm for 4D CT Based on Spatial Continuity[J]. CT Theory and Applications, 2012, 21(3): 401-411.
    [6]YANG Wen-liang, WEI Dong-bo. A Fast Algebraic Reconstruction Algorithm Based on Improved Projection Coefficient Computation[J]. CT Theory and Applications, 2012, 21(2): 187-195.
    [7]YANG Chang-jun, YANG Xin. Abdominal CT Image Segmentation Based on Graph Cuts and Fast Level Set[J]. CT Theory and Applications, 2011, 20(3): 291-300.
    [8]LIU Chun-hua, PAN Jin-xiao. The Study of Cone-Beam ART Algorithm Using Parallel Computing[J]. CT Theory and Applications, 2007, 16(3): 13-19.
    [9]WANG Wei-dong, BAO Shang-lian. Decomposition of Magnetic Resonance Images by Estimating MR Physical Parameters[J]. CT Theory and Applications, 2006, 15(4): 73-78.
    [10]CAI Rui. Applications of Spectral Decomposition Technique to Reservoir Prediction[J]. CT Theory and Applications, 2003, 12(2): 22-25.
  • Cited by

    Periodical cited type(18)

    1. 程义,王志远,王犇,朱汉秋,陈刘成. 基于Revolution CT双低剂量联合ASiR-V技术在超重与肥胖人群头颈CTA中的应用. 医学影像学杂志. 2024(12): 17-21 .
    2. 周冬梅,尹桂秀. 高海拔地区颈动脉体瘤患者的CT能谱成像研究. CT理论与应用研究. 2023(01): 81-89 . 本站查看
    3. 陈新宇,陈伟彬,罗刚,潘红红,张惠英. 低浓度对比剂联合能谱CT在下腔静脉成像中的应用研究. 华北理工大学学报(医学版). 2023(02): 85-89 .
    4. 陈笑,季涛,王国华,高玉庆,黄小铭. 基于能谱CT单能量技术对颈动脉粥样硬化图像质量的研究. 中国临床医学影像杂志. 2023(10): 719-723 .
    5. 刘娜,周宇婧,赵明月,张子敬,方鑫,王旭,李贝贝,袁虹,刘义军,苗延巍. 头颈部CTA中GSI Assist单能量成像结合个体化对比剂注射方案的应用研究. 临床放射学杂志. 2022(04): 741-746 .
    6. 姬龙,余娜,苟瀚恒,何长清,周代全. 能谱CT加MAR技术联合VR降伪影技术对金属植入物的显示能力分析. 中国医疗设备. 2022(08): 177-182 .
    7. 宋双,申洪宪,刘中才,刘建勇. NeuViz Prime型能谱CT最佳单能量技术对行头颅能谱CTA检查患者颅脑结构评价. 中国医学装备. 2021(01): 19-22 .
    8. 丁晓云,石士奎,张平,李聪聪,王瑞瑞,吴瑞. Revolution CT单能量成像联合低管电流、个体化剂量及ASiR技术在头颈部CTA中的应用价值研究. 中国CT和MRI杂志. 2021(05): 147-150 .
    9. 马千里,张中,刘芳. 双能量与单能量CTA在颈动脉体瘤诊断中的应用效果比较. 中国实用医刊. 2021(04): 36-39 .
    10. 崔凌,龙小武,朱志嫦. 脑动脉介入术治疗患者应用能谱CT碘含量定量测定技术评估预后效果的价值观察. 中国CT和MRI杂志. 2021(06): 40-42 .
    11. 李伟峰,聂悦富,梁家浩. 不同剂量对比剂对头颈部CTA成像质量及不良反应的影响. 现代医用影像学. 2021(06): 1106-1108 .
    12. 马光明,于勇,陈静,党珊,于楠,段海峰,窦越群. 能谱CT单能量技术优化头颈CTA图像质量研究. 中国医疗设备. 2021(08): 86-89 .
    13. 余娜,王军大,李治勇,傅浪舟,胡桃. 能谱CT单能量成像联合自适应迭代重建技术对头颈部CT血管成像质量影响及应用价值研究. 现代生物医学进展. 2021(09): 1734-1737 .
    14. 邓小林,谢惠,屈亚林,吴绍全,周帮建,杨正彬,冯练,王敏. 能谱CT最佳单能量成像在胃底静脉曲张出血内镜术前的应用价值. CT理论与应用研究. 2021(05): 603-609 . 本站查看
    15. 龚文胜. 低剂量螺旋CT检查在肺癌高危人群筛查中的应用效果. 中国民康医学. 2021(24): 113-115 .
    16. 杨正彬,谢惠,吴绍全,邓小林. 基于头颈部CTA改良法的个性化扫描初探. 临床放射学杂志. 2020(06): 1064-1068 .
    17. 余娜,严敏,傅浪舟,胡桃,李治勇,钟丽娟,周新杰,周代全. 应用能谱CT技术去除颅内动脉瘤弹簧圈栓塞术后金属伪影. 第三军医大学学报. 2020(20): 2069-2074 .
    18. 吴家伟. 头颈部CTA中的双低剂量对比剂和最佳单能谱成像分析. 中国实用医药. 2019(23): 78-79 .

    Other cited types(8)

Catalog

    Article views (854) PDF downloads (2) Cited by(26)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return