ISSN 1004-4140
CN 11-3017/P
SUN Qi-feng, BAI Qing-yun. Depth Migration Based on Arbitrarily Wide-Angle Wave Equation with Parameters Optimization[J]. CT Theory and Applications, 2011, 20(1): 29-38.
Citation: SUN Qi-feng, BAI Qing-yun. Depth Migration Based on Arbitrarily Wide-Angle Wave Equation with Parameters Optimization[J]. CT Theory and Applications, 2011, 20(1): 29-38.

Depth Migration Based on Arbitrarily Wide-Angle Wave Equation with Parameters Optimization

More Information
  • Received Date: December 23, 2010
  • Available Online: December 12, 2022
  • It is difficult to image the geological structure with strong lateral variation and steep dip. On the basis of the Arbitrarily Wide-Angle Wave Equation(AWWE),we implemented migration with finite difference high-split scheme in frequency-space domain. Optimization of the velocity parameters is a key factor in the accuracy of imaging. The test of impulse response clears that the low order AWWE can be adapted to higher steep dips by optimization of the parameters. The pre-stack migration of Marmousi data shows that the method can handle strong lateral variation and steep dip.
  • Related Articles

    [1]LI Guihua, WANG Shulin, ZHANG Wenbo, XU Ziyu. Combined Boundary of CPML and Feature Analysis within Frequency-Space Domain[J]. CT Theory and Applications, 2022, 31(3): 269-279. DOI: 10.15953/j.ctta.2021.075
    [2]DUAN Chengxiang, LIANG Yuan, FAN Xiaohui, ZHANG Fanchang, WU Jun. Research on High Resolution Seismic Date Processing Method Based on Adaptive VMD[J]. CT Theory and Applications, 2022, 31(2): 135-148. DOI: 10.15953/j.1004-4140.2022.31.02.01
    [3]HU Juan, TANG Guangjian, YANG Xuedong, WANG Xiaoying, LIU Jing, GUO Xiaochao. Optimization of the Measurement of CT Perfusion Parameters of Rectal Carcinoma Recurrence[J]. CT Theory and Applications, 2019, 28(2): 213-220. DOI: 10.15953/j.1004-4140.2019.28.02.07
    [4]CUI Xu-ran, HUO Guo-dong, ZHENG Xiao-xue. Elastic Impedance Parameters Extraction Based on Accumulation Method[J]. CT Theory and Applications, 2015, 24(2): 177-189. DOI: 10.15953/j.1004-4140.2015.24.02.04
    [5]FANG Wen-chun, LAI Li-mei, WU Zhi-guo, WU Bin, SONG Li-le, LUO Xiao-dong. Multislice Spiral CT Scanning on Chest of Optimization of Therapeutic[J]. CT Theory and Applications, 2013, 22(3): 493-499.
    [6]HU Jun-jie, MA Chen-xin, YAN Bin. Optimization of Filter Function in CT Image Reconstruction[J]. CT Theory and Applications, 2013, 22(1): 85-92.
    [7]LI Ruo-mei, WANG Si-wei, JIN Dan-dan. Low-dose CT Coronary Angiography with Status Quo of Tube Current and Voltage Parameters Optimization[J]. CT Theory and Applications, 2012, 21(3): 515-520.
    [8]DAI Qiu-sheng, XU Pin, XING Xiao-man. Optimized Design of X-ray Spectrum Filter for CT[J]. CT Theory and Applications, 2011, 20(3): 331-338.
    [9]SUN Qi-feng. The Frequency-Space Domain Depth Migration Based on Arbitrarily Wide-Angle Wave Equation[J]. CT Theory and Applications, 2010, 19(2): 17-24.
    [10]ZHANG En-jia, WANG Xi-chong, LIANG Dong, TANG Xiao-biao. Beamlet Pre-Stack Depth Migration Based on Gabor Frame Theory[J]. CT Theory and Applications, 2009, 18(3): 38-45.

Catalog

    Article views (1535) PDF downloads (4) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return