ISSN 1004-4140
    CN 11-3017/P
    ZHANG Xiang-chun, JIANG Ying-chun, CAI Liang-xu, WANG Man. Flat Detector X-ray Digital Radiography Tests[J]. CT Theory and Applications, 2011, 20(2): 221-226.
    Citation: ZHANG Xiang-chun, JIANG Ying-chun, CAI Liang-xu, WANG Man. Flat Detector X-ray Digital Radiography Tests[J]. CT Theory and Applications, 2011, 20(2): 221-226.

    Flat Detector X-ray Digital Radiography Tests

    More Information
    • Received Date: December 28, 2010
    • Available Online: December 14, 2022
    • Through the simulation of crack defects of digital transmission imaging specimens,analysis and test studied array detector imaging detection system,parameter,test process and the quality of images,and gives the detection process should be paid attention to.Experiments showed that array detector X-ray digital imaging system in a certain thickness within the scope of the testing results(mainly image quality plan index)single like better than with the thickness of the industrial radiography B level requirement.
    • Related Articles

      [1]WANG Yongsheng, YANG Leiqing, YANG Yifan, PEI Qingxia, WANG Chensi, LU Mengyun, HE Junlin, CHEN Wenjing, TIAN Xiangbao. The Effect of Different Trigger Thresholds on the Quality of Pulmonary Artery CT Angiography Images[J]. CT Theory and Applications, 2024, 33(2): 175-181. DOI: 10.15953/j.ctta.2023.121
      [2]WANG Yongsheng, ZHANG Pengyu, LI Fangzhong, WANG Zhenghua, LU Mengyun, CHEN Lei, HE Junlin, CHEN Wenjing. Study on the Influence of Head and Neck CTA Image Quality under Different Tube Voltages[J]. CT Theory and Applications, 2022, 31(5): 631-638. DOI: 10.15953/j.ctta.2022.026
      [3]LIU Fangtao, LIU Heshi, CHEN Yong, JIANG Jiang, WANG Lingyun, DONG Haipeng, ZHANG Yong, ZHANG Xuan, KONG Deyan, CHANG Rui. Image Quality Assessment for Deep Learning Image Reconstruction Algorithm: A Phantom Study[J]. CT Theory and Applications, 2022, 31(3): 351-356. DOI: 10.15953/j.ctta.2021.061
      [4]FANG Shu, CHEN Linyu, CHEN Yong, DONG Haipeng, WANG Lan, MIN Jihua. Phantom Study on the Influence of CT Model and Tube Voltage on Image Quality[J]. CT Theory and Applications, 2022, 31(3): 345-350. DOI: 10.15953/j.ctta.2021.042
      [5]LIU Min, LIN Yisheng, WANG Fangjun, LI Weihao, LIU Qiong, BAI Chenhui. Correlation of Image Quality and Angiographic Parameters in Two Groups of Angiocatheter by Hepatocellular Carcinoma DSA[J]. CT Theory and Applications, 2019, 28(3): 339-346. DOI: 10.15953/j.1004-4140.2019.28.03.07
      [6]XIA Zhenying, WU Dan, YU Jianan, LI Siyuan, SONG Wenyan. The Influence of Different Noise Indexes on Chest CT Image Quality for Patients with PCP[J]. CT Theory and Applications, 2019, 28(2): 221-228. DOI: 10.15953/j.1004-4140.2019.28.02.08
      [7]ZHANG Hai-bo, FU Chuan-ming, CHEN Lun-gang, XU Lin, WANG Kai-hua. Pitch Optimizing Combination of Thoracic and Abdominal CTA Image Quality and Radiation Dose Discussion[J]. CT Theory and Applications, 2012, 21(2): 305-311.
      [8]LIU Jia-bin, LI Kun-cheng, DU Xiang-ying, LI Peng-yu. Effect of Focal Spot Size on Image Quality in 64-Row MDCT Brain Imaging[J]. CT Theory and Applications, 2008, 17(2): 61-65.
      [9]SHAO Jun-ming, XU Xiao-dong, KONG Jun. Research on CT System Imaging Quality[J]. CT Theory and Applications, 2006, 15(3): 61-67.
      [10]LI Jian-ying. GEVCT–Harmony Between High Image Quality and Low X-ray Dose[J]. CT Theory and Applications, 2006, 15(3): 57-60.