ISSN 1004-4140
CN 11-3017/P
YANG Xiu-jun, CHENG Fu-rong, LI Wei. CT Angiography in Assessment of Arterial Supply of the Femoral Head[J]. CT Theory and Applications, 2011, 20(4): 565-571.
Citation: YANG Xiu-jun, CHENG Fu-rong, LI Wei. CT Angiography in Assessment of Arterial Supply of the Femoral Head[J]. CT Theory and Applications, 2011, 20(4): 565-571.

CT Angiography in Assessment of Arterial Supply of the Femoral Head

More Information
  • Received Date: September 15, 2011
  • Available Online: December 14, 2022
  • Objective: To determine preliminary the values and limits of computed tomographic angiography (CTA)in assessment of arterial supplying to the femur head.Methods: Two thousand and one sets of femoral head thin slice CT axial images in arterial phase were retrospectively 3D reconstructed on AW 4.2 workstation.CTA was obtained by using the 4-detector row CT scanning after single-bolus injection of 95 mL contrast media at 4 mL/s from the peripheral vein.The supply arteries was observed.Results: The CTA sensitivity of MCFA,LCFA and RA were 100%,100%and 28.57%respectively.What were depicted clearly on CTA were their origin,main trunk and proximal portion,and their distal portions were not shown clearly.The method of 3D VR rotation view,using small FOV and minimal value of 75~80 Hu and maximal value of 250~300 Hu,gave good visualization of these vascular structures.Conclusion: It was limited for 4-detector CTA to evaluate the arterial supply of femoral head.
  • Related Articles

    [1]GAO Fang, ZHANG Yan, LIU Zhe, Zhang Gaosheng, XU Min, ZHENG Ying, LI Jian. Application of a Contrast Enhancement Boost Technique in Cranial Four-dimensional Computed Tomography Angiography[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.122
    [2]WANG Xu, YANG Ying, YIN Shuo, WU Ge, DENG Gang, YIN Xiaoming, ZENG Qingyu, DENG Maosong. Study on the Optimal Dosage of Gadolinium Contrast Agent for Lower Extremity Artery CE-MRA Angiography[J]. CT Theory and Applications, 2022, 31(2): 203-210. DOI: 10.15953/j.ctta.2021.033
    [3]LIN Guansheng, DONG Xishan, MA Zhoupeng, WANG Longting. Applicative Study of Double Low Dose Combined with Retrospective ECG Gating in Bronchial Artery CT Angiography[J]. CT Theory and Applications, 2021, 30(1): 91-98. DOI: 10.15953/j.1004-4140.2021.30.01.09
    [4]HE Wei-hong, FU Xi, KE Qi, YUAN Jian-xiang, DONG Xiang-yu. Analysis of 64 Slice Spiral CT Angiography in Diabetic Lower Extremity Arterial Disease[J]. CT Theory and Applications, 2018, 27(3): 373-378. DOI: 10.15953/j.1004-4140.2018.27.03.10
    [5]CHEN Hong-cai, LU Jin-guo, PENG Wan-hong, XI Ren-gang. Diagnosis of Coronary Luminal Stenosis in Dual-source CT Coronary Angiography Using Low-tube-voltage[J]. CT Theory and Applications, 2014, 23(3): 371-377.
    [6]ZHU Ting-ting, GAN Wan-chong. Contrast Quantity and Injection Velocity in Cerebral Angiography with 64 Multi-Detector CT[J]. CT Theory and Applications, 2009, 18(4): 109-114.
    [7]ZHANG Xiu-li, ME Gang, LIU Ying. Application of 64-slice Spiral CT in the Diagnosis of Moyamoya Disease[J]. CT Theory and Applications, 2007, 16(3): 71-75.
    [8]ME Gang, SUN Jian-nan, LIU Wei-li, LI Xue-yan, CHEN Xiu-mei. Application of 16-slice Spiral CT Angiography in Diagnosis of Upper Extremity Arterial Disease[J]. CT Theory and Applications, 2006, 15(4): 26-29.
    [9]LIU Ying, SUN Jian-nan, ZHANG Xiu-li, ME Gang. Research of 16-slice Spiral CT Angiography in Diagnosis of Carotid Body Tumor and Choice of Modus Operandi[J]. CT Theory and Applications, 2006, 15(2): 56-59.
    [10]YAO Gang, SUN Jian-nan, LIU Ying, ZHANG Xiu-li, CHEN Xiu-mei. Feasibility of 16-slice helical CT Angiography with low dose Contrast Agent in the Lower Extremity[J]. CT Theory and Applications, 2005, 14(4): 24-28.

Catalog

    Article views PDF downloads Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return