ISSN 1004-4140
CN 11-3017/P
LANG Dong-jiang, LÜ Cheng-yuan, LUN Zeng-min, SHANG Gen-hua, PAN Wei-yi. Study of Method in Core Analysis by NMRI[J]. CT Theory and Applications, 2012, 21(1): 27-35.
Citation: LANG Dong-jiang, LÜ Cheng-yuan, LUN Zeng-min, SHANG Gen-hua, PAN Wei-yi. Study of Method in Core Analysis by NMRI[J]. CT Theory and Applications, 2012, 21(1): 27-35.

Study of Method in Core Analysis by NMRI

More Information
  • Received Date: October 27, 2011
  • Available Online: December 09, 2022
  • Study of method in core analysis by MRI and Image processing technology.Principle of NMR imaging and Image processing function are described.Through the study of testing rock and math method,and established the methods to analysis formation structure,porosity and porosity distribution image,permeability and permeability distribution image,movable fluid percentage image,identification of water and oil image.The results indicated that testing rock by using MRI technology not only determine porosity and permeability parameter,but observe porosity and permeability distribution image also.Movable fluid in rock is observed by movable fluid percentage image.The method of identification of water and oil give distribution of water and oil in rock,oil and water saturation is calculated.Method in core analysis by MRI can apply to reservoir evaluation,development, experiment,enhance recovery ratio research in oil field.
  • Related Articles

    [1]MIAO Na, QI Xuhong, DU Changyue, CHEN Shiguang, BI Dongmei, WEN Zhiyong. The Application Value of Chest Multi-slice Spiral CT in the Diagnosis of Mass in Dense Breast[J]. CT Theory and Applications, 2020, 29(1): 79-88. DOI: 10.15953/j.1004-4140.2020.29.01.10
    [2]LI Yanju, LIU Xiaoxing, LIANG Shanshan, RAN Caihong, NNDA Zhuoma. Guidance Value of MSCT in the Diagnosis and Clinical Treatment of GST[J]. CT Theory and Applications, 2020, 29(1): 71-77. DOI: 10.15953/j.1004-4140.2020.29.01.09
    [3]XU Guan-zhen, ZOU Wen-yuan, SHI Lei, LIU Yue, CENG Lei, JI Tao-tao, LI Jing-jing, LIN Hua. The Clinical Diagnostic Value of MSCT in Primary Epiploic Appendagitis[J]. CT Theory and Applications, 2017, 26(4): 525-532. DOI: 10.15953/j.1004-4140.2017.26.04.16
    [4]XU Guan-zhen, TONG Cheng-wen, LAN Shan, WANG Lin-lin, LIU Yuan-yuan, LUO Xiao-qin, ZHANG Zi-li, ZOU Wen-yuan. The Diagnosis Value of Solitay Plasmacytoma in Spine Using Multi-slice Computed Tomography[J]. CT Theory and Applications, 2016, 25(2): 183-188. DOI: 10.15953/j.1004-4140.2016.25.02.08
    [5]XU Guan-zhen, CHEN Yu-feng, ZOU Wen-yuan, CAO Yang, HU Jiu-min, HOU Ming-wei, XIONG Liang, TONG Cheng-wen, JI Lei, YANG Qian-qian, ZHOU Lin, CAO Min. MSCT in TNM Staging and Surgical Pathology of Gastric Cancer Control Study[J]. CT Theory and Applications, 2015, 24(3): 429-435. DOI: 10.15953/j.1004-4140.2015.24.03.13
    [6]WANG Ye-qing, ZHUO Guo-ran. Correlation Study on MSCT Manifestation of the Brain Damage and the Clinical Degrees in Neonatal Hypoxic-ischemic Encephalopathy[J]. CT Theory and Applications, 2012, 21(4): 741-746.
    [7]ZHANG Hai-bo, HU Xi-yao, FU Chuan-ming, XU Lin, WANG Kai-hua. MSCT One-stop Recombination in Lumbar Disease Diagnosis Application Value[J]. CT Theory and Applications, 2012, 21(1): 81-88.
    [8]HU Yin-song, HOU Zhi-xiong, DENG Jia-xiu, LI Guo-qiang, LAN Hua, HONG Jian-bin. CT Diagnosis of Neonatal Hypoxic-Ischemic Encephalopathy[J]. CT Theory and Applications, 2011, 20(4): 531-535.
    [9]DENG Jia-xiu, ZHANG Yong-dong. The CT Diagnosis and Clinical Analysis of Neonatal Hypoxic-Ischemic Encephalopathy[J]. CT Theory and Applications, 2008, 17(1): 61-66.
    [10]LIN Shan, LI Kun-cheng, XU Wei, CAO Li-zhen. Diagnosis Obstructive Ureter by MSCT[J]. CT Theory and Applications, 2007, 16(3): 65-70.

Catalog

    Article views (1636) PDF downloads (7) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return