ISSN 1004-4140
CN 11-3017/P
ZHAO Yi-qin, ZU De-gui, ZENG Qing-yu. New Progress of Post 64 Slice CT for Coronary Artery[J]. CT Theory and Applications, 2012, 21(1): 149-155.
Citation: ZHAO Yi-qin, ZU De-gui, ZENG Qing-yu. New Progress of Post 64 Slice CT for Coronary Artery[J]. CT Theory and Applications, 2012, 21(1): 149-155.

New Progress of Post 64 Slice CT for Coronary Artery

More Information
  • Received Date: October 24, 2011
  • Available Online: December 09, 2022
  • 64-slice CT coronary artery imaging has gradually become the important noninvasive test of diagnosis and screening for coronary artery disorder,whose quality is still limited by cardiac arrhythmia,tachycardia,calcification and stents,and it has excessive radiation dose.The paper sums up the progress and disadvantage of post 64 Slice CT such as dual CT,Brilliance ICT,Gemstone CT,and 320 slice CT,shows the radiation dose has been cut down,indicates that tachycardia is settled essentially in Dual CT and Brilliance ICT with the improvement of temporal resolution and cardiac arrhythmia is resolved radically in 320 slice CT,at last,discusses the investigative foreground of post 64 Slice CT for coronary artery.
  • Related Articles

    [1]JI Wenchao, TIAN Weili, LIU Wenya, HE Lianghao, YANG Jian. Application of the Canon 320 Row Variable Helical Pitch CTA System Combined with Iterative Reconstruction Technology for Lower Limb Vascular Imaging[J]. CT Theory and Applications, 2025, 34(1): 149-154. DOI: 10.15953/j.ctta.2024.009
    [2]LIU Yuhang, LI Wei, NIU Yantao, ZHANG Yongxian, WANG Yuchen, YANG Bingbing, LIU dandan. Low-Dose Study on Coronary Artery Calcium Score Scanning Using the SEMI Mode of the Intelligent Optimal Tube Voltage Selection Technique in Combination with an Iterative Algorithm[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.317
    [3]Wu Songwen, Fang Chenyun, Qiao Zhiwei. Enhanced Restormer for Low-Dose CT Image Reconstruction Based on Multi-Attention Fusion[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.052
    [4]FAN Xuelin, WEN Yuqi, QIAO Zhiwei. Sparse Reconstruction of Computed Tomography Images with Transformer Enhanced U-net[J]. CT Theory and Applications, 2024, 33(1): 1-12. DOI: 10.15953/j.ctta.2023.183
    [5]ZHANG Jiahao, QIAO Zhiwei. Computed Tomography Reconstruction Algorithm Based on Relative Total Variation Minimization[J]. CT Theory and Applications, 2023, 32(2): 153-169. DOI: 10.15953/j.ctta.2022.190
    [6]JIANG Yi, QIN Lixin, TIAN Kui, SHA Jinlu, ZHOU Chunhua. Clinical Value of Double Low Examination Technique Based on KARL 3D Iterative Reconstruction Algorithm in Bronchial Artery Imaging[J]. CT Theory and Applications, 2021, 30(6): 753-760. DOI: 10.15953/j.1004-4140.2021.30.06.11
    [7]ZHANG Jun, LIU Jiayi, LIANG Zhipeng. Clinical Application of Low Tube Voltage Combined with Iterative Reconstruction in Lower Extremity Arterial CTA[J]. CT Theory and Applications, 2020, 29(1): 55-60. DOI: 10.15953/j.1004-4140.2020.29.01.07
    [8]CHANG Shao-jie, MOU Xuan-qin. An Iterative Algorithm with Simultaneously Updating the Spectrum and the Image of Dual Energy Computed Tomography[J]. CT Theory and Applications, 2018, 27(1): 45-54. DOI: 10.15953/j.1004-4140.2018.27.01.06
    [9]YANG Min, SUN Chen-xi, XING Chun-xiang, LIU Yong-zhan. Construction of a Teaching and Experimental Platform of Digital Radiography and Industrial Computed Tomography[J]. CT Theory and Applications, 2014, 23(2): 347-356.
    [10]YANG Wen-liang, WEI Dong-bo. A Fast Algebraic Reconstruction Algorithm Based on Improved Projection Coefficient Computation[J]. CT Theory and Applications, 2012, 21(2): 187-195.
  • Cited by

    Periodical cited type(2)

    1. 杨政君,张昂,陈勇,姜江,王凌云,张勇,张璇,齐晓凤. 辐射剂量和管电压对CT图像质量的影响:基于任务的图像质量评价. CT理论与应用研究. 2022(02): 211-217 . 本站查看
    2. 陈思敏,林怀雄,刘昌华,彭晋,林建坤. 小剂量CT扫描技术结合迭代重建算法在下肢静脉血管成像中的应用. 医疗装备. 2019(15): 33-34 .

    Other cited types(0)

Catalog

    Article views (647) PDF downloads (3) Cited by(2)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return