ISSN 1004-4140
CN 11-3017/P
WU He-zhen, LIU Zheng-yi. Simulation Study on Pulse Compression by Bi-phase Coded Excitation with Carrier Modulation[J]. CT Theory and Applications, 2013, 22(1): 41-51.
Citation: WU He-zhen, LIU Zheng-yi. Simulation Study on Pulse Compression by Bi-phase Coded Excitation with Carrier Modulation[J]. CT Theory and Applications, 2013, 22(1): 41-51.

Simulation Study on Pulse Compression by Bi-phase Coded Excitation with Carrier Modulation

More Information
  • Received Date: July 27, 2012
  • Available Online: December 12, 2022
  • In order to introduce the digital encoded technology to the seismic detection,the author studied coded excitation digital simulation and grasped the rules and characters of coded excitation,which is based on the basic coded excitation principle.By modulation launching of coded excitation signal,the author also did simulation research on pulse compression of received signal.Furthermore,the author processed pulse compression with 13 bit signal excitation transducer with one to five units code element(by launching of 13 bit signal excitation transducer with one to five units code element).The author did the power spectrum analyses and analyzed the influence on different excitation signal and its pulse compression result by transducer.
  • Related Articles

    [1]LI Yangsen, QIN Dewen, LIU Qingwen, WANG Xiaopei, Liu Xiaohui. Research on the Identification of Sandstone Vanishing Points Based on Synchronous Compression Matching Pursuit Method[J]. CT Theory and Applications, 2024, 33(5): 551-560. DOI: 10.15953/j.ctta.2024.001
    [2]HAN Xue, ZHAO Jinyong, WANG Zhaohui, GENG Dandan. CT Diagnosis of Median Arcuate Ligament Compression Syndrome with Spontaneous Isolated Superior Mesenteric Artery Dissection: A Case Report[J]. CT Theory and Applications, 2023, 32(4): 567-572. DOI: 10.15953/j.ctta.2023.007
    [3]KONG Lingling, XU Chijie, ZHAO Minyue, DENG Xiaoyi. The Application Value of Dual-Energy CT Virtual Monoenergetic Imaging in the Differential Diagnosis of acute and Chronic Spinal Compression Fractures[J]. CT Theory and Applications, 2021, 30(2): 209-216. DOI: 10.15953/j.1004-4140.2021.30.02.08
    [4]HE Tai-ming, LIU Zheng-yi, LI Shi-yu. Experimental Studies of Ultrasonic Tomography on Fangshan Granite under Uniaxial Compression[J]. CT Theory and Applications, 2015, 24(5): 657-665. DOI: 10.15953/j.1004-4140.2015.24.05.03
    [5]ZHOU Chun-yan, LI Bo, DING Hou-ben. The Study of A Newly-mode Embedded Multi-channel Pulse Amplitude Analyzer[J]. CT Theory and Applications, 2015, 24(1): 69-77. DOI: 10.15953/j.1004-4140.2015.24.01.08
    [6]LIU Yu-ping, LI Li-qing, XUE Hua, DENG Gui-lin, ZHANG Bao-jin. Frequency Shift Processing for the Hypocenter with Short-term Single-frequency Pulse in the Ocean Sub-bottom Profile Data[J]. CT Theory and Applications, 2014, 23(2): 227-235.
    [7]LI Zhang-zheng, SHI Fang-fang, WU He-zhen. Research on Inspecting Concrete Flaws with LFM Signal[J]. CT Theory and Applications, 2014, 23(1): 19-26.
    [8]JIAO Peng-fei, LI Liang, ZHAO Ji. New Advances of Compressed Sensing in Medical Image Reconstruction[J]. CT Theory and Applications, 2012, 21(1): 133-147.
    [9]WU He-zhen, HE Tai-ming. Simulation Study on Coded Excitation in Rock Property Ultrasound Imaging[J]. CT Theory and Applications, 2010, 19(4): 45-52.
    [10]XU Chun-lin, ZHANG Xue-mei, PENG Lei, GUO Yan-zhang, LIU Wei, WANG Jian-guo, ZHU Wei-feng. An Analysis of Clinical and CT of Peripheral Lumbar Spinal Stenosis Compression Lumbar Intervertebral Vein[J]. CT Theory and Applications, 2004, 13(4): 31-35.

Catalog

    Article views PDF downloads Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return