ISSN 1004-4140
    CN 11-3017/P
    ZHANG Fu-kang, MA Jun, LIU Qing-ping, ZHANG Li-yun. The Value of High-Pressure Syringe Constant Speed Automatic Injection in Hysterosalpingography[J]. CT Theory and Applications, 2013, 22(1): 107-113.
    Citation: ZHANG Fu-kang, MA Jun, LIU Qing-ping, ZHANG Li-yun. The Value of High-Pressure Syringe Constant Speed Automatic Injection in Hysterosalpingography[J]. CT Theory and Applications, 2013, 22(1): 107-113.

    The Value of High-Pressure Syringe Constant Speed Automatic Injection in Hysterosalpingography

    More Information
    • Received Date: July 25, 2012
    • Available Online: December 12, 2022
    • Objective:To investigate the value of high-pressure syringe constant speed automatic injection in hysterosalpingography(HSG).Methods:200 cases with infertility,were ivied into two groups including experimental group(n = 100) and control groups(n = 100) according to different injection methods of hysterosalpingography.The experimental group was underwent high-pressure syringe constant speed automatic injection,while the control group underwent traditional manual injection.Results:96 of 100(96%) in the experimental group can be observated dynamically the contrast agent flow into the uterus and the fallopian tube,and be made correct diagnosis.Only 6 of 100(6%) in the control group can be made correct diagnosis of unilateral or bilateral fallopian tubes obstruction.Other 96 cases in the control group cannot be observated dynamically the contrast agent flow into the uterus and the fallopian tube and cannot be made correct diagnosis.In the experimental group,medical personnel can be free from the radiation damage,while the medical personnel are unavoidable damage from the radiation damage.Conclusions:With the application of high pressure injector constant speed automatic injection,hysterosalpingography and injection therapy can be safer,more convenient,more effective state.It can improve the gynecological clinic level in this field and is suitable for clinical widespread application(especially in primary hospitals).
    • Related Articles

      [1]WANG Yongsheng, WANG Chensi, WU Jun, LI Changde, CHEN Wenjing. Application Value of Personalized Contrast Agent Injection Schemes of Different Durations in Pulmonary Artery CTA[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.010
      [2]LIU Yunfu, KANG Tianliang, ZHANG Yongxian, LI Wei, XU Qinggang, WANG Xinyan, XIAN Junfang, NIU Yantao. Study of Two-stage Injection of Contrast Agent in Combination with Bolus Tracking Technique in Computed Tomography Pulmonary Angiography[J]. CT Theory and Applications, 2023, 32(4): 531-538. DOI: 10.15953/j.ctta.2023.075
      [3]WANG Yongsheng, WANG Chensi, LU Haoyu, TIAN Xiangbao, ZHUANG Qixin. Study on the Value of Individualized Contrast Agent Injection Scheme in Improving the Biosafety of Pulmonary Artery CTA[J]. CT Theory and Applications, 2021, 30(6): 777-783. DOI: 10.15953/j.1004-4140.2021.30.06.14
      [4]DAI Yan-zeng, ZHANG Yan, WANG Bin. The Application Value of Automatic Injection on Iodine Colonic Imaging[J]. CT Theory and Applications, 2018, 27(5): 653-658. DOI: 10.15953/j.1004-4140.2018.27.05.12
      [5]CAO Hong-wei, XING Yuan-yuan, CHOU Heng-zhi, ZHANG Dan, CAO Zhen-dong, WAN Li-ye, WANG Sheng-lin. The Effect of Contrast Medium Injection Rate on the Image Quality of Inferior Vena Cava Direct CTV[J]. CT Theory and Applications, 2017, 26(6): 775-782. DOI: 10.15953/j.1004-4140.2017.26.06.15
      [6]GUO Hai-dong, ZHAO Sheng, GUO Xiu-ling, LIU Ai-shi. A Feasibility Study on Coronary Angiography with Flash Technique of Dual-source Computed Tomography by Double Low Technical and Manual Trigger Scanning[J]. CT Theory and Applications, 2016, 25(6): 639-646. DOI: 10.15953/j.1004-4140.2016.25.06.03
      [7]YE Fu-li, SHI Gui-lian. Diagnostic Value of Post-processing Technology of Multi-slice Spiral CT Image for Pulmonary Sequestration[J]. CT Theory and Applications, 2015, 24(5): 747-752. DOI: 10.15953/j.1004-4140.2015.24.05.13
      [8]ZHU Ting-ting, GAN Wan-chong. Contrast Quantity and Injection Velocity in Cerebral Angiography with 64 Multi-Detector CT[J]. CT Theory and Applications, 2009, 18(4): 109-114.
      [9]ZHANG Yuan-fang, LIU Guo-rui, FANG Wen-hui, GUO Yue-lin, LI Yang-kang. The Application of High Pressure Injector in CT Contrast Enhancement[J]. CT Theory and Applications, 2004, 13(2): 46-50.
      [10]Li Gang, Hu Wei, Sun Cunjie, Wang Guoming. X-Knife Position-finding Under CT Scan and Its Cooperation with High-pressure Injector[J]. CT Theory and Applications, 2000, 9(2): 24-27.

    Catalog

      ZHANG Li-yun

      1. On this Site
      2. On Google Scholar
      3. On PubMed
      Article views (1531) PDF downloads (3) Cited by()
      Related

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return