Reduced Contrast Dose CTPA in the Feasibility Study

More Information
  • Received Date: October 05, 2012
  • Available Online: December 12, 2022
  • Objective:by comparing the image quality,reduce the dosage of contrast agent in pulmonary CTA(CTPA) in clinical application.Materials and methods:using Siemens 64 rows of 128 layer spiral CT,60 cases of clinically suspected pulmonary embolism(PAE) were randomly divided into A,B,C 3 group(n = 20),group A:contrast agent 60 mL + 40 mL saline,group B:contrast agent 30 mL + 40 mL saline,group C:contrast agent 20 mL + 40 mL saline,the other scanning parameters were identical,the contrast agent tracking automatic triggering scanning.Will obtain the original data to the workstation,by 1imaging department deputy chief physician and chief technician,in the axial position measurement of pulmonary artery trunk,left,right pulmonary artery from the descending branch of right pulmonary vein and left,CT value,and the vascular enhancement degree,evaluation of recombinant vascular branches.Results:A,B,C 3 group in the pulmonary trunk,left,right pulmonary artery from the descending branch of the average CT values are:(513.20 Hu,504.34 Hu,509.54 Hu),(498.14 Hu,497.43 Hu,499.63 Hu),(486.31 Hu,489.45 Hu,491.49 Hu),the difference between the 3 groups was not statistically significant(P > 0.05),3 groups of left,right pulmonary vein average CT values are:(235.41 Hu,176.31 Hu,119.91 Hu),(241.01 Hu,169.52 Hu,129.54 Hu),difference has statistics significance(P < 0.05),between groups of pulmonary arteriovenous is statistically significant(P < 0.01);recombinant lung vascular definition and branch vessels showed no significant differences(P > 0.05).Conclusion:a small dose of contrast agent(20 mL/time) in CTPA is feasible,not only reduces the contrast agent(CM) on patients of potential hazards,and save the cost of examination.
  • Cited by

    Periodical cited type(2)

    1. 杨政君,张昂,陈勇,姜江,王凌云,张勇,张璇,齐晓凤. 辐射剂量和管电压对CT图像质量的影响:基于任务的图像质量评价. CT理论与应用研究. 2022(02): 211-217 . 本站查看
    2. 陈思敏,林怀雄,刘昌华,彭晋,林建坤. 小剂量CT扫描技术结合迭代重建算法在下肢静脉血管成像中的应用. 医疗装备. 2019(15): 33-34 .

    Other cited types(0)