ISSN 1004-4140
CN 11-3017/P
FANG Wen-chun, LAI Li-mei, WU Zhi-guo, WU Bin, SONG Li-le, LUO Xiao-dong. Multislice Spiral CT Scanning on Chest of Optimization of Therapeutic[J]. CT Theory and Applications, 2013, 22(3): 493-499.
Citation: FANG Wen-chun, LAI Li-mei, WU Zhi-guo, WU Bin, SONG Li-le, LUO Xiao-dong. Multislice Spiral CT Scanning on Chest of Optimization of Therapeutic[J]. CT Theory and Applications, 2013, 22(3): 493-499.

Multislice Spiral CT Scanning on Chest of Optimization of Therapeutic

More Information
  • Received Date: December 19, 2012
  • Available Online: December 12, 2022
  • Objective:To compare the radiation dose between two different collimations on chest low-dose screen and normal using a 16-slice spiral CT,in order to provide guideline for lung low-dose screen.Methods:100 physical examination objectors use 1.5 mm × 16(24 mm) collimation in lung low-dose screen of anomalous.Then use 0.75 mm × 16(12 mm) collimation to screen.They use KVP,Effective mAs,time of ration and image of thick were the same.120 kV,20 mAs,0.5 s/rotation,5 mm.To different overlap 50% reconstruct 2 mm and 1mm thick images for 3D-process.To compare image quality.Results:Four screen technique to display the focus and normal organization of the Lung were not difference.Image quality were excellent,use the wide collimation screen time and X-ray radiation protection too decrease.Conclusion:Radiation dose of 1.5 mm collimation.In lung low-dose screen is less of 0.75 mm collimation,and scan time is low.The radiation dose(CTDIvol) only for the narrow(0.75mm) detector and the conventional dose scanning for 20%,but can provide similar diagnostic information.So a collimation of 1.5mm is recommended in lung low-dose screen using a 16-slice spiral CT.
  • Related Articles

    [1]HU Yanjun, WEI Xuan, ZHANG Yu, TIAN Xin, WANG Likun, JIANG Guilian, NIU Yantao. Effect of External Foreign Bodies on Patient Radiation Dose in Chest CT[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2025.103
    [2]QI Rongfei, JIANG Wenlong, HAO Yunyun, YANG Liusha, CHANG Yingjuan, WU Zhibin. A Study of Image Quality and Radiation Dose in Lower Extremity Computed Tomography Angiography Using Caudo-cranial Flash Scanning[J]. CT Theory and Applications, 2025, 34(3): 385-391. DOI: 10.15953/j.ctta.2024.210
    [3]WANG Chensi, HONG Yao, FANG Huimin, DING Xuelu, YANG Yifan, TIAN Xiangbao, CHEN Wenjing, WANG Yongsheng. Based on the Effect of Different Pitches on Neck CTA Radiation Dose and Image Quality under Automatic Tube Current Modulation Technology[J]. CT Theory and Applications, 2024, 33(3): 309-315. DOI: 10.15953/j.ctta.2023.148
    [4]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [5]CAO Yu, ZHANG Yong-xian. Comparison of Multi-slice Spiral CT Imaging for Cardiac Coronary Arteries with Different Radiation Doses[J]. CT Theory and Applications, 2016, 25(1): 95-101. DOI: 10.15953/j.1004-4140.2016.25.01.12
    [6]WU De-hong, CHEN Shao-bo, FU Chuan-ming, XU Lin, CHEN Lun-gang, YU Guang-ju. Value of Automatic Tube Current Modulation Techniques to Reducing the Radiation Dose in CTU[J]. CT Theory and Applications, 2015, 24(2): 319-325. DOI: 10.15953/j.1004-4140.2015.24.02.18
    [7]CHANG Xin, WANG Xu, FENG Chen-lu. The Effect of Axial and Spiral Scan Mode in Emergency Head CT on Image Quality and Radiation Dosage[J]. CT Theory and Applications, 2015, 24(1): 117-122. DOI: 10.15953/j.1004-4140.2015.24.01.14
    [8]BAO Li-wei, WANG Ze-feng, SUN Zhen-ting, MENG Ling-xin, ZHAO Lei. Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA[J]. CT Theory and Applications, 2015, 24(1): 87-94. DOI: 10.15953/j.1004-4140.2015.24.01.10
    [9]FU Chuan-ming, WU De-hong, XU Lin, CHEN Lun-gang, WANG Zhong-ping, XIONG Yin. Reduce the Radiation Dose in the Lower Extremities to Explore the Feasibility of CTA[J]. CT Theory and Applications, 2014, 23(3): 467-473.
    [10]ZHANG Hai-bo, FU Chuan-ming, CHEN Lun-gang, XU Lin, WANG Kai-hua. Pitch Optimizing Combination of Thoracic and Abdominal CTA Image Quality and Radiation Dose Discussion[J]. CT Theory and Applications, 2012, 21(2): 305-311.

Catalog

    Article views (914) PDF downloads (3) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return