ISSN 1004-4140
CN 11-3017/P
Volume 23 Issue 1
Feb.  2014
Turn off MathJax
Article Contents
ZHANG Yu-long, CHEN Huai-bi, ZHA Hao. Energy Shaping Theory and Simulation for Electron Linac X-ray Source[J]. CT Theory and Applications, 2014, 23(1): 1-8.
Citation: ZHANG Yu-long, CHEN Huai-bi, ZHA Hao. Energy Shaping Theory and Simulation for Electron Linac X-ray Source[J]. CT Theory and Applications, 2014, 23(1): 1-8.

Energy Shaping Theory and Simulation for Electron Linac X-ray Source

More Information
  • Received Date: July 24, 2013
  • Available Online: December 09, 2022
  • Energy shaping technology could be used to reduce artifact error and increase nondestructive testing accuracy.How to produce required spectrum is a key issue.This article proposes spectrums whose peak energy are 3 MeV,6 MeV and 12 MeV especially as required spectrum and discusses calculation method for energy shaping.In order to calculate related parameters,this article simulates X-ray spectrum produced by electron Linac with Monte-Carlo method,makes equation fitting for the X-ray spectrum and linear attenuation coefficients of shaping materials,decides final arrangement for shaping according to calculation results and verifies the arrangement with Monte-Carlo method.
  • Cited by

    Periodical cited type(1)

    1. 阮华珊. 超声在卵巢卵泡膜-纤维瘤组织瘤诊断中的应用价值. 医疗装备. 2020(21): 12-13 .

    Other cited types(0)

Catalog

    Article views (884) PDF downloads (9) Cited by(1)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return